Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Martin Uecker

dblp:40/8374 · DBLP profile ↗
← Back
8ranked-venue papers
0as first author
2since 2021 · last 2024
0000-0002-8850-809XORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 6 · 1 since 2021Artificial intelligence and machine learning · 1 · 1 since 2021Systems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Generative modeling · 50% 3D vision · 50%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Computer graphics and multimedia
1 paper
Image and video processing · 100%

Topics — the 5 heaviest of 5, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Machine learning › Generative modeling
diffusion model
0.812024
Autoregressive Image Diffusion: Generation of Image Sequence and Application in MRI · NeurIPS 2024
Computer vision › 3D vision › medical image reconstruction
MRI reconstruction
0.812024
Autoregressive Image Diffusion: Generation of Image Sequence and Application in MRI · NeurIPS 2024
Medical and health informatics › medical image reconstruction
accelerated MRI reconstruction
0.812024
Autoregressive Image Diffusion: Generation of Image Sequence and Application in MRI · NeurIPS 2024
Medical and health informatics
medical imaging
0.812024
Autoregressive Image Diffusion: Generation of Image Sequence and Application in MRI · NeurIPS 2024
Image and video processing
image reconstruction
0.212024
Autoregressive Image Diffusion: Generation of Image Sequence and Application in MRI · NeurIPS 2024

Methods — techniques the papers use, named apart from their topics

posterior sampling · 2.3autoregressive diffusion · 2.3
YearPublicationVenuePosition
2024 Autoregressive Image Diffusion: Generation of Image Sequence and Application in MRI
abstract
Magnetic resonance imaging (MRI) is a widely used non-invasive imaging modality. However, a persistent challenge lies in balancing image quality with imaging speed. This trade-off is primarily constrained by k-space measurements, which traverse specific trajectories in the spatial Fourier domain (k-space). These measurements are often undersampled to shorten acquisition times, resulting in image artifacts and compromised quality. Generative models learn image distributions and can be used to reconstruct high-quality images from undersampled k-space data. In this work, we present the autoregressive image diffusion (AID) model for image sequences and use it to sample the posterior for accelerated MRI reconstruction. The algorithm incorporates both undersampled k-space and pre-existing information. Models trained with fastMRI dataset are evaluated comprehensively. The results show that the AID model can robustly generate sequentially coherent image sequences. In MRI applications, the AID can outperform the standard diffusion model and reduce hallucinations, due to the learned inter-image dependencies. The project code is available at https://github.com/mrirecon/aid.
Guanxiong Luo, Shoujin Huang, Martin Uecker
NeurIPS3
2023 Free-Breathing Liver Fat, R₂* and B₀ Field Mapping Using Multi-Echo Radial FLASH and Regularized Model-Based Reconstruction
abstract
This work introduced a stack-of-radial multi-echo asymmetric-echo MRI sequence for free-breathing liver volumetric acquisition. Regularized model-based reconstruction was implemented in Berkeley Advanced Reconstruction Toolbox (BART) to jointly estimate all physical parameter maps (water, fat,${R}_{{2}}^{\ast}$, and${B}_{{0}}$field inhomogeneity maps) and coil sensitivity maps from self-gated${k}$-space data. Specifically, locally low rank and temporal total variation regularization were employed directly on physical parameter maps. The proposed free-breathing radial technique was tested on a water/fat & iron phantom, a young volunteer, and obesity/diabetes/hepatic steatosis patients. Quantitative fat fraction and$R_{2}^{\ast}$accuracy were confirmed by comparing our technique with the reference breath-hold Cartesian scan. The multi-echo radial sampling sequence achieves fast${k}$-space coverage and is robust to motion. Moreover, the proposed motion-resolved model-based reconstruction allows for free-breathing liver fat and${R}_{{2}}^{\ast}$quantification in multiple motion states. Overall, our proposed technique offers a convenient tool for non-invasive liver assessment with no breath holding requirement.
Zhengguo Tan, Christina Unterberg-Buchwald, Moritz Blumenthal, Nick Scholand, Philip Schaten, H. Christian M. Holme, Xiaoqing Wang 0003, Dirk Raddatz, Martin Uecker
IEEE Trans. Medical Imaging9
2020 Accelerating Non-Cartesian MRI Reconstruction Convergence Using k-Space Preconditioning
abstract
We propose a k-space preconditioning formulation for accelerating the convergence of iterative Magnetic Resonance Imaging (MRI) reconstructions from non-uniformly sampled k-space data. Existing methods either use sampling density compensations which sacrifice reconstruction accuracy, or circulant preconditioners which increase per-iteration computation. Our approach overcomes both shortcomings. Concretely, we show that viewing the reconstruction problem in the dual formulation allows us to precondition in k-space using density-compensation-like operations. Using the primal-dual hybrid gradient method, the proposed preconditioning method does not have inner loops and are competitive in accelerating convergence compared to existing algorithms. We derive l2 -optimized preconditioners, and demonstrate through experiments that the proposed method converges in about ten iterations in practice.
Frank Ong, Martin Uecker, Michael Lustig
IEEE Trans. Medical Imaging2
2020 Joint T1 and T2 Mapping With Tiny Dictionaries and Subspace-Constrained Reconstruction
abstract
A novel method is developed that adaptively generates tiny dictionaries for joint T1-T2 mapping in magnetic resonance imaging. This work breaks the bond between dictionary size and representation accuracy (i) by approximating the Bloch-response manifold by piece-wise linear functions and (ii) by adaptively refining the sampling grid depending on the locally-linear approximation error. Data acquisition is accomplished with use of an 2D radially sampled Inversion-Recovery Hybrid-State Free Precession sequence. Adaptive dictionaries are generated with different error tolerances and compared to a heuristically designed dictionary. Based on simulation results, tiny dictionaries were used for T1-T2 mapping in phantom and in vivo studies. Reconstruction and parameter mapping were performed entirely in subspace. All experiments demonstrated excellent agreement between the proposed mapping technique and template matching using heuristic dictionaries. Adaptive dictionaries in combination with manifold projection allow to reduce the necessary dictionary sizes by one to two orders of magnitude.
Volkert Roeloffs, Martin Uecker, Jens Frahm
IEEE Trans. Medical Imaging2
2020 Cardiac and Respiratory Self-Gating in Radial MRI Using an Adapted Singular Spectrum Analysis (SSA-FARY)
abstract
Cardiac Magnetic Resonance Imaging (MRI) is time-consuming and error-prone. To ease the patient's burden and to increase the efficiency and robustness of cardiac exams, interest in methods based on continuous steady-state acquisition and self-gating has been growing in recent years. Self-gating methods extract the cardiac and respiratory signals from the measurement data and then retrospectively sort the data into cardiac and respiratory phases. Repeated breathholds and synchronization with the heart beat using some external device as required in conventional MRI are then not necessary. In this work, we introduce a novel self-gating method for radially acquired data based on a dimensionality reduction technique for time-series analysis (SSA-FARY). Building on Singular Spectrum Analysis, a zero-padded, time-delayed embedding of the auto-calibration data is analyzed using Principle Component Analysis. We demonstrate the basic functionality of SSA-FARY using numerical simulations and apply it to in-vivo cardiac radial single-slice bSSFP and Simultaneous Multi-Slice radiofrequency-spoiled gradient-echo measurements, as well as to Stack-of-Stars bSSFP measurements. SSA-FARY reliably detects the cardiac and respiratory motion and separates it from noise. We utilize the generated signals for high-dimensional image reconstruction using parallel imaging and compressed sensing with in-plane wavelet and (spatio-)temporal total-variation regularization.
Sebastian Rosenzweig, Nick Scholand, H. Christian M. Holme, Martin Uecker
IEEE Trans. Medical Imaging4
2014 Fast T2 Mapping With Improved Accuracy Using Undersampled Spin-Echo MRI and Model-Based Reconstructions With a Generating Function
abstract
A model-based reconstruction technique for accelerated T2 mapping with improved accuracy is proposed using undersampled Cartesian spin-echo magnetic resonance imaging (MRI) data. The technique employs an advanced signal model for T2 relaxation that accounts for contributions from indirect echoes in a train of multiple spin echoes. An iterative solution of the nonlinear inverse reconstruction problem directly estimates spin-density and T2 maps from undersampled raw data. The algorithm is validated for simulated data as well as phantom and human brain MRI at 3T. The performance of the advanced model is compared to conventional pixel-based fitting of echo-time images from fully sampled data. The proposed method yields more accurate T2 values than the mono-exponential model and allows for retrospective undersampling factors of at least 6.Although limitations are observed for very long T2 relaxation times, respective reconstruction problems may be overcome by a gradient dampening approach. The analytical gradient of the utilized cost function is included as appendix. The source code is made available to the community.
Tilman J. Sumpf, Andreas Petrovic, Martin Uecker, Florian Knoll, Jens Frahm
IEEE Trans. Medical Imaging3
2012 A Multi-GPU Programming Library for Real-Time Applications
Sebastian Schaetz, Martin Uecker
ICA3PP (1)2
2009 Model-Based Iterative Reconstruction for Radial Fast Spin-Echo MRI
abstract
In radial fast spin-echo magnetic resonance imaging (MRI), a set of overlapping spokes with an inconsistent T2 weighting is acquired, which results in an averaged image contrast when employing conventional image reconstruction techniques. This work demonstrates that the problem may be overcome with the use of a dedicated reconstruction method that further allows for T2 quantification by extracting the embedded relaxation information. Thus, the proposed reconstruction method directly yields a spin-density and relaxivity map from only a single radial data set. The method is based on an inverse formulation of the problem and involves a modeling of the received MRI signal. Because the solution is found by numerical optimization, the approach exploits all data acquired. Further, it handles multicoil data and optionally allows for the incorporation of additional prior knowledge. Simulations and experimental results for a phantom and human brain in vivo demonstrate that the method yields spin-density and relaxivity maps that are neither affected by the typical artifacts from TE mixing, nor by streaking artifacts from the incomplete k-space coverage at individual echo times.
Kai Tobias Block, Martin Uecker, Jens Frahm
IEEE Trans. Medical Imaging2