EDBT 2026 Demo / reviewers in the wild / expert
Edward J. Vigmond
dblp:41/1250
· DBLP profile ↗
13ranked-venue papers
0as first author
10since 2021 · last 2026
0000-0003-1388-3589ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 13 · 10 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2026 | Recovering intrinsic conduction velocity and action potential duration from electroanatomic mapping data using curvatureabstractElectroanatomic mapping systems measure the spread of activation and recovery over the surface of the heart. Propagation in cardiac tissue is complicated by the tissue architecture which produces a spatially varying anisotropic conductivity, leading to complex wavefronts. Curvature of the wavefront is known to affect both conduction velocity (CV) and action potential duration (APD). In this study, we sought to better define the impact of wavefront curvature on these properties, as well as the influence of conductivity, in order to recover intrinsic tissue properties. The dependence of CV and APD on curvature were measured for positive and negative curvatures for several ionic models, and then verified in realistic 2D and 3D simulations. Clinical data were also analysed. Results indicate that the effects of APD and CV are well described by simple formulae, and if the structure of the fibre is known, the intrinsic propagation velocities can be recovered. Geometrical curvature, as determined strictly by wavefront shape and ignoring the fibre structure, leads to large regions of spurious high curvature. This is important for determining pathological zones of slow conduction. In the simulations studied, curvature modulated APD by at most 20 ms. • New expression for influence of wavefront curvature on action potential duration. • Conduction velocity dependence on curvature for several cardiac cell models shown. • Method to find intrinsic values from measured ones, independent of activation origin. • Curvature broken down into geometrical and anisotropic components. Caroline H. Roney, Gernot Plank, Shohreh Honarbakhsh, Caterina Vidal Horrach, Simone Pezzuto, Edward J. Vigmond |
Medical Image Anal. | 6 |
| 2026 | An efficient end-to-end computational framework for the generation of ECG calibrated volumetric models of human atrial electrophysiologyabstractComputational models of atrial electrophysiology (EP) are increasingly utilized for applications such as the development of advanced mapping systems, personalized clinical therapy planning, and the generation of virtual cohorts and digital twins. These models have the potential to establish robust causal links between simulated in silico behaviors and observed human atrial EP, enabling safer, cost-effective, and comprehensive exploration of atrial dynamics. However, current state-of-the-art approaches lack the fidelity and scalability required for regulatory-grade applications, particularly in creating high-quality virtual cohorts or patient-specific digital twins. Challenges include anatomically accurate model generation, calibration to sparse and uncertain clinical data, and computational efficiency within a streamlined workflow. This study addresses these limitations by introducing novel methodologies integrated into an automated end-to-end workflow for generating high-fidelity digital twin snapshots and virtual cohorts of atrial EP. These innovations include: (i) automated multi-scale generation of volumetric biatrial models with detailed anatomical structures and fiber architecture; (ii) a robust method for defining space-varying atrial parameter fields; (iii) a parametric approach for modeling inter-atrial conduction pathways; and (iv) an efficient forward EP model for high-fidelity electrocardiogram computation. We evaluated this workflow on a cohort of 50 atrial fibrillation patients, producing high-quality meshes suitable for reaction-eikonal and reaction-diffusion models and demonstrating the ability to simulate atrial ECGs under parametrically controlled conditions. These advancements represent a critical step toward scalable, precise, and clinically applicable digital twin models and virtual cohorts, enabling enhanced patient-specific predictions and therapeutic planning. Elena Zappon, Luca Azzolin, Matthias A. F. Gsell, Franz Thaler, Anton J. Prassl, Robert Arnold, Karli Gillette, Mohammadreza Kariman, Martin Manninger, Daniel Scherr, Aurel Neic, Martin Urschler, Christoph M. Augustin, Edward J. Vigmond, Gernot Plank |
Medical Image Anal. | 14 |
| 2023 | Cell to whole organ global sensitivity analysis on a four-chamber heart electromechanics model using Gaussian processes emulatorsabstractCardiac pump function arises from a series of highly orchestrated events across multiple scales. Computational electromechanics can encode these events in physics-constrained models. However, the large number of parameters in these models has made the systematic study of the link between cellular, tissue, and organ scale parameters to whole heart physiology challenging. A patient-specific anatomical heart model, or digital twin, was created. Cellular ionic dynamics and contraction were simulated with the Courtemanche-Land and the ToR-ORd-Land models for the atria and the ventricles, respectively. Whole heart contraction was coupled with the circulatory system, simulated with CircAdapt, while accounting for the effect of the pericardium on cardiac motion. The four-chamber electromechanics framework resulted in 117 parameters of interest. The model was broken into five hierarchical sub-models: tissue electrophysiology, ToR-ORd-Land model, Courtemanche-Land model, passive mechanics and CircAdapt. For each sub-model, we trained Gaussian processes emulators (GPEs) that were then used to perform a global sensitivity analysis (GSA) to retain parameters explaining 90% of the total sensitivity for subsequent analysis. We identified 45 out of 117 parameters that were important for whole heart function. We performed a GSA over these 45 parameters and identified the systemic and pulmonary peripheral resistance as being critical parameters for a wide range of volumetric and hemodynamic cardiac indexes across all four chambers. We have shown that GPEs provide a robust method for mapping between cellular properties and clinical measurements. This could be applied to identify parameters that can be calibrated in patient-specific models or digital twins, and to link cellular function to clinical indexes. Marina Strocchi, Stefano Longobardi, Christoph M. Augustin, Matthias A. F. Gsell, Argyrios Petras, C. Aldo Rinaldi, Edward J. Vigmond, Gernot Plank, Chris J. Oates, Richard Wilkinson, Steven A. Niederer |
PLoS Comput. Biol. | 7 |
| 2022 | Detection of focal source and arrhythmogenic substrate from body surface potentials to guide atrial fibrillation ablationabstractFocal sources (FS) are believed to be important triggers and a perpetuation mechanism for paroxysmal atrial fibrillation (AF). Detecting FS and determining AF sustainability in atrial tissue can help guide ablation targeting. We hypothesized that sustained rotors during FS-driven episodes indicate an arrhythmogenic substrate for sustained AF, and that non-invasive electrical recordings, like electrocardiograms (ECGs) or body surface potential maps (BSPMs), could be used to detect FS and AF sustainability. Computer simulations were performed on five bi-atrial geometries. FS were induced by pacing at cycle lengths of 120-270 ms from 32 atrial sites and four pulmonary veins. Self-sustained reentrant activities were also initiated around the same 32 atrial sites with inexcitable cores of radii of 0, 0.5 and 1 cm. FS fired for two seconds and then AF inducibility was tested by whether activation was sustained for another second. ECGs and BSPMs were simulated. Equivalent atrial sources were extracted using second-order blind source separation, and their cycle length, periodicity and contribution, were used as features for random forest classifiers. Longer rotor duration during FS-driven episodes indicates higher AF inducibility (area under ROC curve = 0.83). Our method had accuracy of 90.6±1.0% and 90.6±0.6% in detecting FS presence, and 93.1±0.6% and 94.2±1.2% in identifying AF sustainability, and 80.0±6.6% and 61.0±5.2% in determining the atrium of the focal site, from BSPMs and ECGs of five atria. The detection of FS presence and AF sustainability were insensitive to vest placement (±9.6%). On pre-operative BSPMs of 52 paroxysmal AF patients, patients classified with initiator-type FS on a single atrium resulted in improved two-to-three-year AF-free likelihoods (p-value < 0.01, logrank tests). Detection of FS and arrhythmogenic substrate can be performed from ECGs and BSPMs, enabling non-invasive mapping towards mechanism-targeted AF treatment, and malignant ectopic beat detection with likely AF progression. Yingjing Feng, Caroline H. Roney, Jason D. Bayer, Steven A. Niederer, Mélèze Hocini, Edward J. Vigmond |
PLoS Comput. Biol. | 6 |
| 2022 | Correction: Linking statistical shape models and simulated function in the healthy adult human heartabstract[This corrects the article DOI: 10.1371/journal.pcbi.1008851.]. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 10 |
| 2021 | A Framework for the generation of digital twins of cardiac electrophysiology from clinical 12-leads ECGsabstractCardiac digital twins (Cardiac Digital Twin (CDT)s) of human electrophysiology (Electrophysiology (EP)) are digital replicas of patient hearts derived from clinical data that match like-for-like all available clinical observations. Due to their inherent predictive potential, CDTs show high promise as a complementary modality aiding in clinical decision making and also in the cost-effective, safe and ethical testing of novel EP device therapies. However, current workflows for both the anatomical and functional twinning phases within CDT generation, referring to the inference of model anatomy and parameters from clinical data, are not sufficiently efficient, robust and accurate for advanced clinical and industrial applications. Our study addresses three primary limitations impeding the routine generation of high-fidelity CDTs by introducing; a comprehensive parameter vector encapsulating all factors relating to the ventricular EP; an abstract reference frame within the model allowing the unattended manipulation of model parameter fields; a novel fast-forward electrocardiogram (Electrocardiogram (ECG)) model for efficient and bio-physically-detailed simulation required for parameter inference. A novel workflow for the generation of CDTs is then introduced as an initial proof of concept. Anatomical twinning was performed within a reasonable time compatible with clinical workflows (<4h) for 12 subjects from clinically-attained magnetic resonance images. After assessment of the underlying fast forward ECG model against a gold standard bidomain ECG model, functional twinning of optimal parameters according to a clinically-attained 12 lead ECG was then performed using a forward Saltelli sampling approach for a single subject. The achieved results in terms of efficiency and fidelity demonstrate that our workflow is well-suited and viable for generating biophysically-detailed CDTs at scale. Karli Gillette, Matthias A. F. Gsell, Anton J. Prassl, Elias Karabelas, Ursula Reiter, Gert Reiter, Thomas Grandits, Christian Payer, Darko Stern, Martin Urschler, Jason D. Bayer, Christoph M. Augustin, Aurel Neic, Thomas Pock, Edward J. Vigmond, Gernot Plank |
Medical Image Anal. | 15 |
| 2021 | A novel method to correct repolarization time estimation from unipolar electrograms distorted by standard filteringabstractReliable patient-specific ventricular repolarization times (RTs) can identify regions of functional block or afterdepolarizations, indicating arrhythmogenic cardiac tissue and the risk of sudden cardiac death. Unipolar electrograms (UEs) record electric potentials, and the Wyatt method has been shown to be accurate for estimating RT from a UE. High-pass filtering is an important step in processing UEs, however, it is known to distort the T-wave phase of the UE, which may compromise the accuracy of the Wyatt method. The aim of this study was to examine the effects of high-pass filtering, and improve RT estimates derived from filtered UEs. We first generated a comprehensive set of UEs, corresponding to early and late activation and repolarization, that were then high-pass filtered with settings that mimicked the CARTO filter. We trained a deep neural network (DNN) to output a probabilistic estimation of RT and a measure of confidence, using the filtered synthetic UEs and their true RTs. Unfiltered ex-vivo human UEs were also filtered and the trained DNN used to estimate RT. Even a modest 2 Hz high-pass filter imposes a significant error on RT estimation using the Wyatt method. The DNN outperformed the Wyatt method in 62.75% of cases, and produced a significantly lower absolute error (p=8.99E-13), with a median of 16.91 ms, on 102 ex-vivo UEs. We also applied the DNN to patient UEs from CARTO, from which an RT map was computed. In conclusion, DNNs trained on synthetic UEs improve the RT estimation from filtered UEs, which leads to more reliable repolarization maps that help to identify patient-specific repolarization abnormalities. Peter Langfield, Yingjing Feng, Laura Bear, Josselin Duchateau, Rafael Sebastián, Emma Abell, Rémi Dubois, Louis Labrousse, Julien Rogier, Mélèze Hocini, Michel Haïssaguerre, Edward J. Vigmond |
Medical Image Anal. | 12 |
| 2021 | A computational model of pig ventricular cardiomyocyte electrophysiology and calcium handling: Translation from pig to human electrophysiologyabstractThe pig is commonly used as an experimental model of human heart disease, including for the study of mechanisms of arrhythmia. However, there exist differences between human and porcine cellular electrophysiology: The pig action potential (AP) has a deeper phase-1 notch, a longer duration at 50% repolarization, and higher plateau potentials than human. Ionic differences underlying the AP include larger rapid delayed-rectifier and smaller inward-rectifier K+-currents (IKr and IK1 respectively) in humans. AP steady-state rate-dependence and restitution is steeper in pigs. Porcine Ca2+ transients can have two components, unlike human. Although a reliable computational model for human ventricular myocytes exists, one for pigs is lacking. This hampers translation from results obtained in pigs to human myocardium. Here, we developed a computational model of the pig ventricular cardiomyocyte AP using experimental datasets of the relevant ionic currents, Ca2+-handling, AP shape, AP duration restitution, and inducibility of triggered activity and alternans. To properly capture porcine Ca2+ transients, we introduced a two-step process with a faster release in the t-tubular region, followed by a slower diffusion-induced release from a non t-tubular subcellular region. The pig model behavior was compared with that of a human ventricular cardiomyocyte (O'Hara-Rudy) model. The pig, but not the human model, developed early afterdepolarizations (EADs) under block of IK1, while IKr block led to EADs in the human but not in the pig model. At fast rates (pacing cycle length = 400 ms), the human cell model was more susceptible to spontaneous Ca2+ release-mediated delayed afterdepolarizations (DADs) and triggered activity than pig. Fast pacing led to alternans in human but not pig. Developing species-specific models incorporating electrophysiology and Ca2+-handling provides a tool to aid translating antiarrhythmic and arrhythmogenic assessment from the bench to the clinic. Namit Gaur, Xiao-Yan Qi, David Benoist, Olivier Bernus, Ruben Coronel, Stanley Nattel, Edward J. Vigmond |
PLoS Comput. Biol. | 7 |
| 2021 | Linking statistical shape models and simulated function in the healthy adult human heartabstractCardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n = 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R = 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 10 |
| 2021 | Estimation of Personalized Minimal Purkinje Systems From Human Electro-Anatomical MapsabstractThe Purkinje system is a heart structure responsible for transmitting electrical impulses through the ventricles in a fast and coordinated way to trigger mechanical contraction. Estimating a patient-specific compatible Purkinje Network from an electro-anatomical map is a challenging task, that could help to improve models for electrophysiology simulations or provide aid in therapy planning, such as radiofrequency ablation. In this study, we present a methodology to inversely estimate a Purkinje network from a patient's electro-anatomical map. First, we carry out a simulation study to assess the accuracy of the method for different synthetic Purkinje network morphologies and myocardial junction densities. Second, we estimate the Purkinje network from a set of 28 electro-anatomical maps from patients, obtaining an optimal conduction velocity in the Purkinje network of 1.95 ± 0.25 m/s, together with the location of their Purkinje-myocardial junctions, and Purkinje network structure. Our results showed an average local activation time error of 6.8±2.2 ms in the endocardium. Finally, using the personalized Purkinje network, we obtained correlations higher than 0.85 between simulated and clinical 12-lead ECGs. Fernando Barber, Peter Langfield, Miguel Lozano 0001, Ignacio García-Fernández, Josselin Duchateau, Mélèze Hocini, Michel Haïssaguerre, Edward J. Vigmond, Rafael Sebastián |
IEEE Trans. Medical Imaging | 8 |
| 2019 | Universal atrial coordinates applied to visualisation, registration and construction of patient specific meshesabstractIntegrating spatial information about atrial physiology and anatomy in a single patient from multimodal datasets, as well as generalizing these data across patients, requires a common coordinate system. In the atria, this is challenging due to the complexity and variability of the anatomy. We aimed to develop and validate a Universal Atrial Coordinate (UAC) system for the following applications: combination and assessment of multimodal data; comparison of spatial data across patients; 2D visualization; and construction of patient specific geometries to test mechanistic hypotheses. Left and right atrial LGE-MRI data were segmented and meshed. Two coordinates were calculated for each atrium by solving Laplace's equation, with boundary conditions assigned using five landmark points. The coordinate system was used to map spatial information between atrial meshes, including scalar fields measured using different mapping modalities, and atrial anatomic structures and fibre directions from a reference geometry. Average error in point transfer from a source mesh to a destination mesh and back again was less than 0.1 mm for the left atrium and 0.02 mm for the right atrium. Patient specific meshes were constructed using the coordinate system and phase singularity density maps from arrhythmia simulations were visualised in 2D. In conclusion, we have developed a universal atrial coordinate system allowing automatic registration of imaging and electroanatomic mapping data, 2D visualisation, and patient specific model creation. Caroline H. Roney, Ali Pashaei, Marianna Meo, Rémi Dubois, Patrick M. Boyle, Natalia A. Trayanova, Hubert Cochet, Steven A. Niederer, Edward J. Vigmond |
Medical Image Anal. | 9 |
| 2018 | Universal ventricular coordinates: A generic framework for describing position within the heart and transferring dataabstractBeing able to map a particular set of cardiac ventricles to a generic topologically equivalent representation has many applications, including facilitating comparison of different hearts, as well as mapping quantities and structures of interest between them. In this paper we describe Universal Ventricular Coordinates (UVC), which can be used to describe position within any biventricular heart. UVC comprise four unique coordinates that we have chosen to be intuitive, well defined, and relevant for physiological descriptions. We describe how to determine these coordinates for any volumetric mesh by illustrating how to properly assign boundary conditions and utilize solutions to Laplace's equation. Using UVC, we transferred scalar, vector, and tensor data between four unstructured ventricular meshes from three different species. Performing the mappings was very fast, on the order of a few minutes, since mesh nodes were searched in a KD tree. Distance errors in mapping mesh nodes back and forth between meshes were less than the size of an element. Analytically derived fiber directions were also mapped across meshes and compared, showing < 5° difference over most of the ventricles. The ability to transfer gradients was also demonstrated. Topologically variable structures, like papillary muscles, required further definition outside of the UVC framework. In conclusion, UVC can aid in transferring many types of data between different biventricular geometries. Jason D. Bayer, Anton J. Prassl, Ali Pashaei, Juan F. Gomez, Antonio Frontera, Aurel Neic, Gernot Plank, Edward J. Vigmond |
Medical Image Anal. | 8 |
| 2018 | Variability in pulmonary vein electrophysiology and fibrosis determines arrhythmia susceptibility and dynamicsabstractSuccess rates for catheter ablation of persistent atrial fibrillation patients are currently low; however, there is a subset of patients for whom electrical isolation of the pulmonary veins alone is a successful treatment strategy. It is difficult to identify these patients because there are a multitude of factors affecting arrhythmia susceptibility and maintenance, and the individual contributions of these factors are difficult to determine clinically. We hypothesised that the combination of pulmonary vein (PV) electrophysiology and atrial body fibrosis determine driver location and effectiveness of pulmonary vein isolation (PVI). We used bilayer biatrial computer models based on patient geometries to investigate the effects of PV properties and atrial fibrosis on arrhythmia inducibility, maintenance mechanisms, and the outcome of PVI. Short PV action potential duration (APD) increased arrhythmia susceptibility, while longer PV APD was found to be protective. Arrhythmia inducibility increased with slower conduction velocity (CV) at the LA/PV junction, but not for cases with homogeneous CV changes or slower CV at the distal PV. Phase singularity (PS) density in the PV region for cases with PV fibrosis was increased. Arrhythmia dynamics depend on both PV properties and fibrosis distribution, varying from meandering rotors to PV reentry (in cases with baseline or long APD), to stable rotors at regions of high fibrosis density. Measurement of fibrosis and PV properties may indicate patient specific susceptibility to AF initiation and maintenance. PV PS density before PVI was higher for cases in which AF terminated or converted to a macroreentry; thus, high PV PS density may indicate likelihood of PVI success. Caroline H. Roney, Jason D. Bayer, Hubert Cochet, Marianna Meo, Rémi Dubois, Pierre Jaïs, Edward J. Vigmond |
PLoS Comput. Biol. | 7 |