Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Simon R. Cherry

dblp:45/4808 · DBLP profile ↗
← Back
6ranked-venue papers
1as first author
0since 2021 · last 2020
0000-0002-0155-5644ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 6 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%

Topics — the 5 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › medical imaging › nuclear medicine imaging
positron emission tomography
0.522020
Machine Learning in PET: From Photon Detection to Quantitative Image Reconstruction · Proc. IEEE 2020
The Integration of Positron Emission Tomography With Magnetic Resonance Imaging · Proc. IEEE 2008
Medical and health informatics › medical imaging › nuclear medicine imaging
PET image reconstruction
0.412020
Machine Learning in PET: From Photon Detection to Quantitative Image Reconstruction · Proc. IEEE 2020
Medical and health informatics
medical imaging
0.112008
The Integration of Positron Emission Tomography With Magnetic Resonance Imaging · Proc. IEEE 2008
Medical and health informatics › medical imaging
multimodal imaging
0.112008
The Integration of Positron Emission Tomography With Magnetic Resonance Imaging · Proc. IEEE 2008
Medical and health informatics › medical imaging
magnetic resonance imaging
0.012008
The Integration of Positron Emission Tomography With Magnetic Resonance Imaging · Proc. IEEE 2008

Methods — techniques the papers use, named apart from their topics

machine learning · 0.4simultaneous acquisition · 0.1imaging agent development · 0.1
YearPublicationVenuePosition
2020 Machine Learning in PET: From Photon Detection to Quantitative Image Reconstruction
abstract
Machine learning has found unique applications in nuclear medicine from photon detection to quantitative image reconstruction. While there have been impressive strides in detector development for time-of-flight positron emission tomography, most detectors still make use of simple signal processing methods to extract the time and position information from the detector signals. Now with the availability of fast waveform digitizers, machine learning techniques have been applied to estimate the position and arrival time of high-energy photons. In quantitative image reconstruction, machine learning has been used to estimate various corrections factors, including scattered events and attenuation images, as well as to reduce statistical noise in reconstructed images. Here machine learning either provides a faster alternative to an existing time-consuming computation, such as in the case of scatter estimation, or creates a data-driven approach to map an implicitly defined function, such as in the case of estimating the attenuation map for PET/MR scans. In this article, we will review the abovementioned applications of machine learning in nuclear medicine.
Kuang Gong, Eric Berg, Simon R. Cherry, Jinyi Qi
Proc. IEEE3
2016 Improving Depth, Energy and Timing Estimation in PET Detectors with Deconvolution and Maximum Likelihood Pulse Shape Discrimination
abstract
In a scintillation detector, the light generated in the scintillator by a gamma interaction is converted to photoelectrons by a photodetector and produces a time-dependent waveform, the shape of which depends on the scintillator properties and the photodetector response. Several depth-of-interaction (DOI) encoding strategies have been developed that manipulate the scintillator's temporal response along the crystal length and therefore require pulse shape discrimination techniques to differentiate waveform shapes. In this work, we demonstrate how maximum likelihood (ML) estimation methods can be applied to pulse shape discrimination to better estimate deposited energy, DOI and interaction time (for time-of-flight (TOF) PET) of a gamma ray in a scintillation detector. We developed likelihood models based on either the estimated detection times of individual photoelectrons or the number of photoelectrons in discrete time bins, and applied to two phosphor-coated crystals (LFS and LYSO) used in a previously developed TOF-DOI detector concept. Compared with conventional analytical methods, ML pulse shape discrimination improved DOI encoding by 27% for both crystals. Using the ML DOI estimate, we were able to counter depth-dependent changes in light collection inherent to long scintillator crystals and recover the energy resolution measured with fixed depth irradiation (~11.5% for both crystals). Lastly, we demonstrated how the Richardson-Lucy algorithm, an iterative, ML-based deconvolution technique, can be applied to the digitized waveforms to deconvolve the photodetector's single photoelectron response and produce waveforms with a faster rising edge. After deconvolution and applying DOI and time-walk corrections, we demonstrated a 13% improvement in coincidence timing resolution (from 290 to 254 ps) with the LFS crystal and an 8% improvement (323 to 297 ps) with the LYSO crystal.
Eric Berg, Emilie Roncali, Will Hutchcroft, Jinyi Qi, Simon R. Cherry
IEEE Trans. Medical Imaging5
2008 The Integration of Positron Emission Tomography With Magnetic Resonance Imaging
abstract
A number of laboratories and companies are currently exploring the development of integrated imaging systems for magnetic resonance imaging (MRI) and positron emission tomography (PET). Scanners for both preclinical and human research applications are being pursued. In contrast to the widely distributed and now quite mature PET/computed tomography technology, most PET/MRI designs allow for simultaneous rather than sequential acquisition of PET and MRI data. While this offers the possibility of novel imaging strategies, it also creates considerable challenges for acquiring artifact-free images from both modalities. This paper discusses the motivation for developing combined PET/MRI technology, outlines the obstacles in realizing such an integrated instrument, and presents recent progress in the development of both the instrumentation and of novel imaging agents for combined PET/MRI studies. The performance of the first-generation PET/MRI systems is described. Finally, a range of possible biomedical applications for PET/MRI are outlined.
Simon R. Cherry, Angelique Y. Louie, Russell E. Jacobs
Proc. IEEE1
2000 Comparison of 3D maximum a posteriori and filtered backprojection algorithms for high resolution animal imaging with microPET
abstract
We have evaluated the performance of two three-dimensional (3-D) reconstruction algorithms with data acquired from microPET, a high resolution tomograph dedicated to small animal imaging. The first was a linear filtered-backprojection algorithm (FBP) with reprojection of the missing data, and the second was a statistical maximum a posteriori probability algorithm (MAP). The two algorithms were evaluated in terms of their resolution performance, both in phantoms and in vivo. Sixty independent realizations of a phantom simulating the brain of a baby monkey were acquired, each containing three million counts. Each of these realizations was reconstructed independently with both algorithms. The ensemble of the 60 reconstructed realizations was used to estimate the standard deviation as a measure of the noise for each reconstruction algorithm. More detail was recovered in the MAP reconstruction without an increase in noise relative to FBP. Studies in a simple cylindrical compartment phantom demonstrated improved recovery of known activity ratios with MAP. Finally, in vivo studies also demonstrated a clear improvement in spatial resolution using the MAP algorithm. The quantitative accuracy of the MAP reconstruction was also evaluated by comparison with autoradiography and direct well counting of tissue samples and was shown to be superior.
Arion Chatziioannou, Jinyi Qi, Alex Annala, K. Nguyen, Richard M. Leahy, Simon R. Cherry
IEEE Trans. Medical Imaging7
1998 An Evaluation of Exact and Approximate 3-D Reconstruction Algorithms for a High-Resolution, Small Animal PET Scanner
abstract
MicroPET is a low-cost, high-resolution positron emission tomography (PET) scanner designed for imaging small animals. MicroPET operates exclusively without septa, acquiring fully three-dimensional (3-D) data sets. The performance of the projection-reprojection (3DRP), variable axial rebinning (VARB), single slice rebinning (SSRB), and Fourier rebinning (FORE) methods for reconstruction of microPET data were evaluated. The algorithms were compared with respect to resolution, noise variance, and reconstruction time. Results suggested that the 3DRP algorithm gives the best combination of resolution and noise performance in 9 min of reconstruction time on a Sun UltraSparc I workstation. The FORE algorithm provided the most acceptable accelerated method of reconstruction, giving similar resolution performance with a 10%-20% degradation in noise variance in under 2 min. Significant degradation in the axial resolution was measured with the VARB and SSRB methods, offsetting the decrease in reconstruction time achieved with those methods. In-plane angular mashing of the 3-D data before reconstruction led to a 50% reduction in reconstruction time but also introduced unacceptable tangential blurring artifacts. This thorough evaluation of analytical 3-D reconstruction techniques allowed for optimal selection of a reconstruction method for the diverse range of microPET applications.
T. H. Farquhar, Arion Chatziioannou, Simon R. Cherry
IEEE Trans. Medical Imaging3
1994 Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images
abstract
The authors describe conjugate gradient algorithms for reconstruction of transmission and emission PET images. The reconstructions are based on a Bayesian formulation, where the data are modeled as a collection of independent Poisson random variables and the image is modeled using a Markov random field. A conjugate gradient algorithm is used to compute a maximum a posteriori (MAP) estimate of the image by maximizing over the posterior density. To ensure nonnegativity of the solution, a penalty function is used to convert the problem to one of unconstrained optimization. Preconditioners are used to enhance convergence rates. These methods generally achieve effective convergence in 15-25 iterations. Reconstructions are presented of an (18)FDG whole body scan from data collected using a Siemens/CTI ECAT931 whole body system. These results indicate significant improvements in emission image quality using the Bayesian approach, in comparison to filtered backprojection, particularly when reprojections of the MAP transmission image are used in place of the standard attenuation correction factors.
Erkan U. Mumcuoglu, Richard M. Leahy, Simon R. Cherry
IEEE Trans. Medical Imaging3