Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Laurent Barbé

dblp:47/5883 · DBLP profile ↗
← Back
10ranked-venue papers
2as first author
2since 2021 · last 2024
0000-0002-0226-8903ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 10 · 2 first-author · 2 since 2021Systems, architecture and hardware · 10 · 2 first-author · 2 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
6 papers
Robot manipulation · 67% Motion planning and robot control · 33%
Human-computer interaction and pervasive computing
4 papers
Human-robot interaction · 64% Haptics and multimodal interaction · 36%
Interdisciplinary, comprehensive, and emerging computing
3 papers
Medical and health informatics · 100%

Topics — the 17 heaviest of 17, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › actuation › pneumatic artificial muscle
pneumatic actuator
0.812024
A non-magnetic dual-mode linear pneumatic actuator: initial design and assessment · ICRA 2024
Haptics and multimodal interaction › haptic feedback
force feedback
0.522021
Using comanipulation with active force feedback to undistort stiffness perception in laparoscopy · ICRA 2019
Rate Mode Bilateral Teleoperation Based on Passivity Tanks and Variable Admittance Control · ICRA 2021
Robotics › Motion planning and robot control › robot control
admittance control
0.512021
Rate Mode Bilateral Teleoperation Based on Passivity Tanks and Variable Admittance Control · ICRA 2021
Robotics › Motion planning and robot control › robot control › admittance control
variable admittance control
0.512021
Rate Mode Bilateral Teleoperation Based on Passivity Tanks and Variable Admittance Control · ICRA 2021
Human-robot interaction › teleoperation
bilateral teleoperation
0.512021
Rate Mode Bilateral Teleoperation Based on Passivity Tanks and Variable Admittance Control · ICRA 2021
Medical and health informatics
medical robotics
0.432024
A non-magnetic dual-mode linear pneumatic actuator: initial design and assessment · ICRA 2024
Hydraulically-actuated compliant revolute joint for medical robotic systems based on multimaterial additive manufacturing · ICRA 2019
A novel actuation technology for safe physical human-robot interactions · ICRA 2014
Robotics › Robot manipulation › robot design › manipulator design
compliant joint design
0.412019
Hydraulically-actuated compliant revolute joint for medical robotic systems based on multimaterial additive manufacturing · ICRA 2019
Robotics › Robot manipulation
robot design
0.412019
Hydraulically-actuated compliant revolute joint for medical robotic systems based on multimaterial additive manufacturing · ICRA 2019
Human-robot interaction › physical human-robot interaction
comanipulation
0.412019
Using comanipulation with active force feedback to undistort stiffness perception in laparoscopy · ICRA 2019
Robotics › Robot manipulation › robot design
robot mechanism design
0.212014
A novel actuation technology for safe physical human-robot interactions · ICRA 2014
Human-robot interaction
physical human-robot interaction
0.212014
A novel actuation technology for safe physical human-robot interactions · ICRA 2014
Robotics › Robot manipulation › cable-driven robot
cable-driven manipulator
0.112012
Development of a MR-compatible cable-driven manipulator: Design and technological issues · ICRA 2012
Robotics › Robot manipulation › medical robotics
MRI-compatible robot
0.112012
Development of a MR-compatible cable-driven manipulator: Design and technological issues · ICRA 2012
Robotics › Robot manipulation › medical robotics › surgical robotics
minimally invasive surgery
0.112019
Using comanipulation with active force feedback to undistort stiffness perception in laparoscopy · ICRA 2019
Haptics and multimodal interaction › haptic interface
haptic device design
0.112007
Design and Evaluation of a Linear Haptic Device · ICRA 2007
Robotics › Motion planning and robot control
robot control
0.012012
Development of a MR-compatible cable-driven manipulator: Design and technological issues · ICRA 2012
Human-robot interaction › teleoperation
telemanipulation
0.012007
Design and Evaluation of a Linear Haptic Device · ICRA 2007

Methods — techniques the papers use, named apart from their topics

step-by-step control · 1.5continuous mode control · 1.5passivity-based control · 1.0energy monitoring · 1.0rack-and-pinion mechanism · 0.8passive teleoperation · 0.8lever ratio compensation · 0.8force reflection · 0.8static balancing · 0.6multimaterial additive manufacturing · 0.4multi-material additive manufacturing · 0.4trajectory tracking control · 0.4force feedback · 0.1
YearPublicationVenuePosition
2024 A non-magnetic dual-mode linear pneumatic actuator: initial design and assessment
abstract
A pneumatic linear actuator is presented and evaluated. Designed to operate in demanding environments such as MRI, it is developed to be used with two motion control modes: 1) a step-by-step mode with tooth-based gripping to ensure precision, 2) a continuous mode available locally for fine positioning. The actuator can also be disengaged to enable direct handling by an operator, for example for comanipulation. The design is presented. A prototype, developed in the medical context, is implemented and characterized. A specific step-by-step control sequence is then elaborated based on its characterization. Testing of the dual-mode actuation is finally described. The complementarity between the two motion modes and possible adaptations of the original design are discussed.
Timothée Portha, Laurent Barbé, François Geiskopf, Jonathan Vappou, Pierre Renaud
ICRA2
2021 Rate Mode Bilateral Teleoperation Based on Passivity Tanks and Variable Admittance Control
abstract
Bilateral teleoperation under rate mode is known to be a difficult problem in terms of stability, especially when the slave manipulator interacts with a time-varying environment. This paper presents an energy based variable admittance control approach, whose principle combines the monitoring and the regulation of the energy exchanges with a passivity tank. It allows stable interactions with force feedback for any desired inertia, damping and stiffness parameters. Experiments are conducted to assess the efficiency of the proposed approach using an experimental setup with a variable stiffness environment. The obtained results illustrate the ability of the proposed strategy to stabilize a system otherwise unstable, with little effect on the transparency of the teleoperation system.
Charlélie Saudrais, Laurent Barbé, Bernard Bayle
ICRA2
2019 Hydraulically-actuated compliant revolute joint for medical robotic systems based on multimaterial additive manufacturing
abstract
In this paper, an active compliant revolute joint actuated by hydraulic energy is developed. The joint is made of polymer for integration in medical robotic systems, even in a challenging environment such as Magnetic Resonance Imaging (MRI). The use of multimaterial additive manufacturing allows us to develop two original aspects. First, a new seal design is proposed to build miniature hydraulic cylinders embedded in the active joint, with low level of friction. Second, a rack-and-pinion mechanism is being integrated to a compliant revolute joint to obtain a high level of compactness. Design and experimental assessment of the hydraulic cylinder and the compliant joint with embedded rack-and-pinion are presented, as well as an illustration in the context of needle manipulation with passive teleoperation.
Antoine Pfeil, Marius Siegfarth, François Geiskopf, T. P. Pusch, Laurent Barbé, Pierre Renaud
ICRA5
2019 Using comanipulation with active force feedback to undistort stiffness perception in laparoscopy
abstract
Surgeons performing laparoscopic surgery experience distortion when perceiving the stiffness of a patient's tissues. This is due to the lever effect induced by the introduction of instruments in their patient's body through a fulcrum. To address this problem, we propose to use the comanipulation paradigm. A robotic device is connected to the handle of the instrument while simultaneously being held by the surgeon. This device applies a force on the handle that reflects the force measured at the tool tip, with a gain that depends on the lever ratio. The implementation of this method is presented on an experimental setup and a preliminary assessment experiment is presented.
François Schmitt, Josue Sulub, Ignacio Avellino, Jimmy Da Silva, Laurent Barbé, Olivier Piccin, Bernard Bayle, Guillaume Morel
ICRA5
2018 An Origami-Inspired Flexible Pneumatic Actuator
abstract
This paper presents a new actuator designed to produce forces under short stroke displacements. Two variants of the prototype have been manufactured using Multi-Material Additive Manufacturing process, based on a flexible origami-inspired architecture. The structure consists of an airtight chamber constituted by rigid plates combined with flexible hinges and surfaces in order to allow the generation of motion. We propose several insights on integration issues such as limited material resistance and maximum range of motion. Both versions of the prototype are then tested to assess their performances for single strokes and cyclic loading.
François Schmitt, Olivier Piccin, Laurent Barbé, Bernard Bayle
IROS3
2014 A novel actuation technology for safe physical human-robot interactions
abstract
The design of intrinsically safe systems is an important issue in the development of physical human-robot interactions, in particular in the medical field. In this paper, we explore a new approach, motivated by a medical robotic application framework. The system is statically balanced, in any configuration. Its actuation results from a controllable modification of the balancing. This notably limits the interaction forces between the robot and its environment, but yet authorizes important features like accurate positioning or tracking while in contact, which are key characteristics for the application. In this paper, the robotic device principle is introduced, together with its original actuation, which is developed and experimentally assessed for a one DOF system. Capabilities such as trajectory tracking in the free space, reaction to unexpected collision and tracking of a moving environment are reported. The generalization to more DOF, as required to complete medical tasks, is also discussed.
Laure Esteveny, Laurent Barbé, Bernard Bayle
ICRA2
2012 Development of a MR-compatible cable-driven manipulator: Design and technological issues
abstract
In this paper, we focus on the technology issues to be solved to develop a cable-driven robot compatible with Magnetic Resonance Imaging constraints. This study is based on the design of a new compact cable-driven manipulator with remote actuators, initially developed for prostate interventions. One of the originalities of the system is to use an instrumented structure to evaluate the cable tensions and lengths in order to perform an adequate control. The sensors assessment has been experimentally achieved and the necessity to introduce a new control strategy using the developed sensors has been demonstrated.
Salih Abdelaziz, Laure Esteveny, Laurent Barbé, Pierre Renaud, Bernard Bayle, Michel de Mathelin
ICRA3
2010 Design of a linear haptic display based on approximate straight line mechanisms
abstract
In this paper, we study a class of one degree-of-freedom mechanisms in order to design linear haptic interfaces. They allow to perform straight line motions with only revolute joints, thus limiting the friction that characterizes linear bearings. We particularly describe the characteristics of these systems and their good properties to design haptic displays: parallel architecture, very good linearity, good use of the actuator torque. The Hoeken's mechanism which has the best characteristics to build a direct drive general purpose haptic display is selected. We present the fabricated prototype and its evaluation in terms of bandwidth, Coulomb friction and apparent mass.
Mathieu Joinié-Maurin, Laurent Barbé, Olivier Piccin, Jacques Gangloff, Bernard Bayle, Romain Rump
IROS2
2008 User adapted control of force feedback teleoperators: Evaluation and robustness analysis
abstract
This paper addresses the influence of human operators on telemanipulators bilateral control. A method to deal with the user variability is proposed, based on the auto-tuning of the force controller at the master side. First, the approach is evaluated experimentally with a group of users in the context of nonlinear interactions with soft tissues, showing very good tracking performances, for both force and position. Second, a robustness analysis is presented that allows to prove the stability of the system for large variations of the behavior of both the environment and the user. This analysis is based on an original uncertain model of the user.
Laurent Barbé, Bernard Bayle, Edouard Laroche, Michel de Mathelin
IROS1
2007 Design and Evaluation of a Linear Haptic Device
abstract
The commercial development of haptic devices is very promising. Existing systems are often 6-degree-of-freedom mechanisms equipped with a stylus that acts as a tool. They exhibit force feedback for 3 or 6 degrees of freedom of their end-effector, depending on whether only forces or both forces and torques are rendered. Some planar devices are also used but oddly, one-degree-of-freedom linear haptic devices are quite rare. This lack can probably be explained by the necessary mechanical transformations that are required to achieve linear motions with rotary motors. In this paper, we review several possible structures and present the design of a new one-degree-of-freedom linear haptic device with a limited number of joints and a compact design, compatible with rotary actuation. We evaluate this device in the telemanipulation context.
Laurent Barbé, Bernard Bayle, Jacques Gangloff, Michel de Mathelin, Olivier Piccin
ICRA1