Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Pamela Al Haddad

dblp:49/10064 · DBLP profile ↗
← Back
1ranked-venue papers
1as first author
0since 2021 · last 2011
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Systems, architecture and hardware · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer architecture, parallel and distributed computing, and storage systems
1 paper
Electronic design automation · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Electronic design automation
physical design
0.112011
Power grid correction using sensitivity analysis under an RC model · DAC 2011
Electronic design automation › physical design
power grid verification
0.012011
Power grid correction using sensitivity analysis under an RC model · DAC 2011

Methods — techniques the papers use, named apart from their topics

sensitivity analysis · 0.1nonlinear optimization · 0.1RC model · 0.1
YearPublicationVenuePosition
2011 Power grid correction using sensitivity analysis under an RC model
abstract
Verifying an RC model of the power grid requires one to check if the steady state voltage drops on all the nodes of the grid do not exceed a certain threshold. We propose an approach to correct the grid, in case some voltage drops violate the threshold condition, by making minor changes to the original design. Previous work has been done in [1] on the DC model of the grid and this paper deals with the transient model. Rather than directly reducing the steady state voltage drops below the threshold we work on reducing the first time step voltage drops. The method uses current constraints proposed in [2] to find the first time step voltage drop whose distance to the corresponding threshold is the largest. It then tries to estimate it as a function of the metal widths on the grid. A non-linear optimization problem is then formulated and the required metal line width changes that reduce the first time step voltage drops by a sufficient amount are then determined. The reduction of the first time step voltage drop by that amount will make the steady state voltage drops of all the nodes less than the threshold.
Pamela Al Haddad, Farid N. Najm
DAC1