Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data.

Thomas J. Withrow

dblp:49/2877 · DBLP profile ↗
← Back
7ranked-venue papers
1as first author
0since 2021 · last 2019
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 1 first-authorSystems, architecture and hardware · 4 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 2Human-computer interaction and ubiquitous computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
3 papers
Wearable and physiological sensing · 65% Accessibility and assistive technology · 20% Health and well-being technologies · 14%
Artificial intelligence
4 papers
Robot manipulation · 85% Motion planning and robot control · 15%

Topics — the 12 heaviest of 14, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Wearable and physiological sensing
gait analysis
0.212015
Design and implementation of an instrumented cane for gait recognition · ICRA 2015
Wearable and physiological sensing › gait analysis
gait recognition
0.212015
Design and implementation of an instrumented cane for gait recognition · ICRA 2015
Robotics › Robot manipulation › actuator design
pneumatic actuation
0.122008
A forearm actuation unit for an upper extremity prosthesis · ICRA 2008
A Gas-Actuated Anthropomorphic Transhumeral Prosthesis · ICRA 2007
Health and well-being technologies › rehabilitation technology
rehabilitation robotics
0.112009
Design and simulation of a joint-coupled orthosis for regulating FES-aided gait · ICRA 2009
Robotics › Robot manipulation
grasping
0.112008
A forearm actuation unit for an upper extremity prosthesis · ICRA 2008
Robotics › Robot manipulation › wearable robotics › prosthetic device
prosthetic hand
0.112008
A forearm actuation unit for an upper extremity prosthesis · ICRA 2008
Robotics › Robot manipulation
robotic hand
0.112007
A Gas-Actuated Anthropomorphic Transhumeral Prosthesis · ICRA 2007
Accessibility and assistive technology › assistive technology
assistive device
0.112015
Design and implementation of an instrumented cane for gait recognition · ICRA 2015
Robotics › Motion planning and robot control › robot control
feedback control
0.012009
Design and simulation of a joint-coupled orthosis for regulating FES-aided gait · ICRA 2009
Robotics › Motion planning and robot control › robot control › force control
force tracking control
0.012008
A forearm actuation unit for an upper extremity prosthesis · ICRA 2008
Robotics › Motion planning and robot control
robot control
0.012008
A Gas-Actuated Anthropomorphic Prosthesis for Transhumeral Amputees · IEEE Trans. Robotics 2008
Robotics › Robot manipulation
robot design
0.012007
A Gas-Actuated Anthropomorphic Transhumeral Prosthesis · ICRA 2007

Methods — techniques the papers use, named apart from their topics

servovalve design · 0.2gait pattern classification · 0.2embedded sensing · 0.2functional electrical stimulation · 0.2dynamic simulation · 0.2monopropellant gas generator · 0.1pneumatic actuators · 0.1pneumatic actuation · 0.1monopropellant hydrogen peroxide · 0.1closed-loop force control · 0.1
YearPublicationVenuePosition
2019 Feasibility of Automated Mobility Assessment of Older Adults via an Instrumented Cane
abstract
This study explored the feasibility of automated characterization of functional mobility via an Instrumented Cane System (ICS) within an older adult sample of cane users. An off-the-shelf offset cane was instrumented with inertial, force, and ultrasound sensors for noninvasive data collection. Eighteen patients from a neurological out-patient rehabilitation clinic and nine independently mobile controls participated in standard clinical evaluations of mobility using the ICS while under the care of an attending physical therapist. Feasibility of the ICS was gauged through two studies. The first demonstrated the capability of the ICS to reliably collect meaningful usage metrics, and the second provided preliminary support for the discriminability of high and low falls risk from system-reported metrics. Specifically, the cane significantly differentiated patients and controls (p < 0.05), and a measure of the variation in rotational velocity was associated with total scores on the Functional Gait Assessment (partial r = 0.61, p < 0.01). These findings may ultimately serve to complement and even extend current clinical assessment practices.
Joshua W. Wade, Robert Boyles, Patricia Flemming, Arpan Sarkar, Michael de Riesthal, Thomas J. Withrow, Nilanjan Sarkar
IEEE J. Biomed. Health Informatics6
2015 Design and implementation of an instrumented cane for gait recognition
abstract
Independent mobility is an important aspect of an individual's life and must sometimes be augmented by use of an assistive device such as a wheeled walker or cane following a fall, injury, or functional decline. Physical therapists perform functional gait assessments to gauge the probability of an individual experiencing a fall and often recommend use of a walker, cane, or walking stick to decrease fall risk. Our team has developed a clinical assessment tool centered on a standard walking cane embedded system that can enhance a therapist's observation-based gait assessment with use of additional objective and quantitative data. This system can be utilized to detect timing and speed of cane placement, angular acceleration of the cane, and amounts of weight borne on the cane. This system is designed to assist physical therapists at the basic level in collection of objective data during gait analysis, to facilitate appropriate assistive gait device prescription, to provide patients and therapists feedback during gait training, and to reduce wrist and shoulder injuries with cane usage. However, more importantly, using the plethora of objective data that can be obtained from this cane, automated gait analysis and gait pattern classification can be performed to understand a patient's walking performance.
Joshua W. Wade, Marco Beccani, Alec Myszka, Esube Bekele, Pietro Valdastri, Patricia Flemming, Michael de Riesthal, Thomas J. Withrow, Nilanjan Sarkar
ICRA8
2011 Toward haptic/aural touchscreen display of graphical mathematics for the education of blind students
abstract
We propose the use of a haptic touchscreen to convey graphical and mathematical concepts through aural and/or vibratory tactile feedback. We hypothesize that an important application of such a display will be in teaching visually impaired students concepts that are traditionally learned almost entirely visually. This paper describes initial feasibility studies using a commercially available haptic touchscreen to display grids, points, lines, and shapes - some of the first visual graphical entities students encounter in K-12 mathematics education, and from which more complex lessons can be constructed. We conducted user studies designed to evaluate perception of these objects through haptic feedback alone, auditory feedback alone, and combinations of the two. Our results indicate that both sensory channels can be valuable in user perception.
Jenna L. Toennies, Jessica Burgner-Kahrs, Thomas J. Withrow, Robert J. Webster III
World Haptics3
2009 Design and simulation of a joint-coupled orthosis for regulating FES-aided gait
abstract
A hybrid functional electrical stimulation (FES)/orthosis system is being developed which combines two channels of (surface-electrode-based) electrical stimulation with a computer-controlled orthosis for the purpose of restoring gait to spinal cord injured (SCI) individuals (albeit with a stability aid, such as a walker). The orthosis is an energetically passive, controllable device which 1) unidirectionally couples hip to knee flexion; 2) aids hip and knee flexion with a spring assist; and 3) incorporates sensors and modulated friction brakes, which are used in conjunction with electrical stimulation for the feedback control of joint (and therefore limb) trajectories. This paper describes the hybrid FES approach and the design of the joint coupled orthosis. A dynamic simulation of an SCI individual using the hybrid approach is described, and results from the simulation are presented that indicate the promise of the JCO approach.
Ryan J. Farris, Hugo A. Quintero, Thomas J. Withrow, Michael Goldfarb
ICRA3
2008 A forearm actuation unit for an upper extremity prosthesis
abstract
This paper presents the design of a 14 degree-of-motion forearm actuation unit for an upper extremity prosthesis. The forearm utilizes pneumatic type actuators which use the reaction products of a monopropellant gas generator as a working fluid. The use of pneumatic type actuators provides a near-human power density, such that the fourteen actuator forearm unit can deliver approximately one half of the force and power capability of a human arm, with a total package size that fits within the volumetric constraints of a 50thpercentile female forearm (excluding the cartridge of liquid propellant). This paper describes the design of the forearm. The design has been fabricated, and experimental results are presented that demonstrate the closed-loop force tracking capability. An accompanying video further demonstrates the forearm performance.
Thomas J. Withrow, Xiangrong Shen, Jason E. Mitchell, Michael Goldfarb
ICRA1
2008 A Gas-Actuated Anthropomorphic Prosthesis for Transhumeral Amputees
abstract
This paper presents the design of a gas-actuated anthropomorphic arm prosthesis with 21 degrees of freedom and nine independent actuators. The prosthesis utilizes the monopropellant hydrogen peroxide as a gas generator to power nine pneumatic type actuators. Of the nine independent actuators, one provides direct- drive actuation of the elbow, three provide direct-drive actuation for the wrist, and the remaining five actuate an underactuated 17 degree of freedom hand. This paper describes the design of the prosthesis, including the design of small-scale high-performance servovalves, which enable the implementation of the monopropellant concept in a transhumeral prosthesis. Experimental results are given characterizing both the servovalve performance and the force and/or motion control of various joints under closed-loop control.
Kevin B. Fite, Thomas J. Withrow, Xiangrong Shen, Keith W. Wait, Jason E. Mitchell, Michael Goldfarb
IEEE Trans. Robotics2
2007 A Gas-Actuated Anthropomorphic Transhumeral Prosthesis
abstract
This paper presents the design of an anthropomorphic 21 degree-of-freedom, 9 degree-of-actuation arm prosthesis for use by transhumeral amputees. The design leverages the power density of pneumatic actuation with the energy density of liquid propellants to obtain a self-powered dexterous prosthesis in which all of the requisite power, actuation, and sensing is packaged within the volumetric envelope of a normal human arm. Specifically, the arm utilizes a monopropellant as a gas generator to power nine pneumatic-type actuators that drive an elbow, three wrist degrees-of-freedom, and a 17 degree-of-freedom compliant hand. The design considerations discussed in this work include the design of compact, low-power servovalves; the choice of actuators based on energetic requirements of a normal arm; the design of compact elbow and wrist joints with integrated position and force sensing; and the components of the compliant hand design. The liquid-fueled prosthesis is expected to approach the dexterity of an anatomical arm and is projected to deliver half of the force and power output of an average human arm.
Kevin B. Fite, Thomas J. Withrow, Keith W. Wait, Michael Goldfarb
ICRA2