Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data.

Makoto Negoro

dblp:52/135 · DBLP profile ↗
← Back
26ranked-venue papers
0as first author
1since 2021 · last 2022
0000-0003-3482-3198ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Systems, architecture and hardware · 24 · 1 since 2021Artificial intelligence and machine learning · 23Graphics, computer vision, multimedia, augmented reality and games · 2Applied, interdisciplinary, general and emerging computing · 2

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
9 papers
Medical and health informatics · 97% Bioinformatics and computational biology · 3%
Artificial intelligence
9 papers
Robot manipulation · 70% Motion planning and robot control · 30%
Computer graphics and multimedia
3 papers
Computational fabrication · 100%

Topics — the 15 heaviest of 18, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › medical simulation
surgical simulation
0.332013
In-vitro intravascular simulator with quantitative evaluation for surgical tools used in cerebral aneurysm surgery based on stress analysis · ICRA 2013
Patient-specific Neurovascular Simulator for Evaluating the Performance of Medical Robots and Instruments · ICRA 2006
An In Vitro Soft Membranous Model of Individual Human Cerebral Artery Reproduced with Visco-elastic Behavior · ICRA 2004
Medical and health informatics
surgical robotics
0.352012
Stress analysis during micro-coil deployment in membranous model of saccular aneurysm with bleb · ICRA 2012
Photoelastic stress analysis error quantification in vasculature models for robot feedback control · ICRA 2010
Force Display Method to Improve Safety in Teleoperation System for Intravascular Neurosurgery · ICRA 1999
Robotics › Robot manipulation › medical robotics
surgical robotics
0.122013
In-vitro intravascular simulator with quantitative evaluation for surgical tools used in cerebral aneurysm surgery based on stress analysis · ICRA 2013
New Catheter Driving Method using Linear Stepping Mechanism for Intravascular Neurosurgery · ICRA 2002
Robotics › Motion planning and robot control
robot control
0.131999
Force Display Method to Improve Safety in Teleoperation System for Intravascular Neurosurgery · ICRA 1999
Augmentation of Safety in Teleoperation System for Intravascular Neurosurgery · ICRA 1998
Micro force sensor for intravascular neurosurgery · ICRA 1997
Robotics › Motion planning and robot control
teleoperation
0.021999
Force Display Method to Improve Safety in Teleoperation System for Intravascular Neurosurgery · ICRA 1999
Augmentation of Safety in Teleoperation System for Intravascular Neurosurgery · ICRA 1998
Bioinformatics and computational biology
regenerative medicine
0.012007
Patient-Specific Blood Vessel Scaffold for Regenerative Medicine · ICRA 2007
Robotics › Robot manipulation
force sensing
0.011997
Micro force sensor for intravascular neurosurgery · ICRA 1997
Human-robot interaction
teleoperation
0.011996
Multimedia tele-surgery using high speed optical fiber network and its application to intravascular neurosurgery - system configuration and computer networked robotic implementation · ICRA 1996
Health and well-being technologies › surgical robotics
telesurgery
0.011996
Multimedia tele-surgery using high speed optical fiber network and its application to intravascular neurosurgery - system configuration and computer networked robotic implementation · ICRA 1996
Robotics › Robot manipulation › medical robotics
active catheter
0.011994
Micro Active Catheter System with Multi Degrees of Freedom · ICRA 1994
Robotics › Robot manipulation
medical robotics
0.011994
Micro Active Catheter System with Multi Degrees of Freedom · ICRA 1994
Robotics › Robot manipulation › medical robotics
catheter steering
0.012002
New Catheter Driving Method using Linear Stepping Mechanism for Intravascular Neurosurgery · ICRA 2002
Robotics › Robot manipulation › telemanipulation
master-slave teleoperation
0.012002
New Catheter Driving Method using Linear Stepping Mechanism for Intravascular Neurosurgery · ICRA 2002
Content delivery and video streaming
multimedia transmission
0.011996
Multimedia tele-surgery using high speed optical fiber network and its application to intravascular neurosurgery - system configuration and computer networked robotic implementation · ICRA 1996
Internet architecture and protocols
quality of service
0.011996
Multimedia tele-surgery using high speed optical fiber network and its application to intravascular neurosurgery - system configuration and computer networked robotic implementation · ICRA 1996

Methods — techniques the papers use, named apart from their topics

photoelastic stress analysis · 1.0virtual reality modeling · 0.5image processing · 0.5epoxy resin modeling · 0.3polariscope · 0.2camera calibration · 0.2salt leaching · 0.1dip coating · 0.1stress evaluation · 0.1CT/MRI reconstruction · 0.1visco-elastic tissue modeling · 0.0medical imaging · 0.0master-slave control · 0.0linear stepping mechanism · 0.0virtual simulator · 0.0asynchronous transfer mode · 0.0
YearPublicationVenuePosition
2022 FPL Demo: A Flexible and Scalable Quantum-Classical Interface based on FPGAs
abstract
This demonstration shows a Quantum-Classical interface (QC-IF) for quantum computing implemented on multiple FPGAs. Quantum computers need a controller to transmit/receive microwave to/from quantum devices. In order to explore various quantum devices, the controller requires flexibility to transmit/receive various wave shapes. In addition to that, scalability is also required for large-scale quantum computers. FPGAs are attractive platforms; however, some challenges exist in implementing QC-IF on FPGAs in terms of required specifications from physics, such as treating data and realizing scalability. This work demonstrates an implementation of QC-IF on FPGA with high bandwidth memory to treat large-volume data in high throughput. Furthermore, the IEEE1588-like clock synchronization mechanism is implemented to make multiple FPGAs synchronized.
Takefumi Miyoshi, Keisuke Koike, Shinichi Morisaka, Hidehisa Shiomi, Kazuhisa Ogawa, Yutaka Tabuchi, Makoto Negoro
FPL7
2013 In-vitro intravascular simulator with quantitative evaluation for surgical tools used in cerebral aneurysm surgery based on stress analysis
abstract
This paper presents a new in-vitro simulator that can simulate the new technology of three-dimensional digital subtraction angiography (DSA) to perform a cerebral aneurysm surgery. Then, propose a new technique for the numerical evaluation of the surgical tools applied within this interventional surgery to aid in the design and selection of surgical instruments. Initially, the in-vitro intravascular simulator was constructed, followed by cerebral aneurysm models that were fabricated with highly sensitive photoelastic materials of epoxy resin. Then reconstruct virtual reality modeling of the blood vessel and catheter to record the position information and realize virtual guidance for training. Meanwhile, conduct image processing of photoelastic effects for numerical evaluations of surgical instruments such as catheter insertion and stent expansion. During the stent expansion experiment, the average stress in the selected region of interest caused by the expansion was calculated and compared with the corresponding value obtained before the expansion. The presented simulator and measurement technique can assist in improving a surgeons skills, quantifying the performance of medical mechanisms, and contribute to 3D analysis of stress distribution. This approach can also provide feedback control for robot assisted endovascular systems.
Chaoyang Shi, Masahiro Kojima, Carlos Tercero, Zoran Najdovski, Hirokatsu Kodama, Masahiro Nakajima, Seiichi Ikeda, Toshio Fukuda, Fumihito Arai, Makoto Negoro
ICRA10
2012 Stress analysis during micro-coil deployment in membranous model of saccular aneurysm with bleb
abstract
For the development of medical micro-robotics and robotic manipulation of catheter it is necessary to ensure tissue integrity. In-vitro evaluation of tissue manipulation can be achieved using photoelastic stress analysis and vasculature modeling with photoelastic materials. In this research we propose epoxy resin as photoelastic material for vasculature modeling as it has a larger photoelastic coefficient than previously studied materials and it has a young modulus similar to human vasculature. A model of a saccular aneurysm with bleb was built with the purpose of measuring stress overshoots that enable to differentiate embolization techniques according to the respect for tissue integrity. During embolization using a coil with smaller size than the aneurysm dome diameter, an average area of 0.72 mm2with stress above 90 kPa was measured. This area increased to 0.77 mm2when the dome was touched with the release mechanism of the coil, and to 0.74 mm2for embolization with larger size coil. The presented modeling material and measurement technique is useful for tissue respect quantification for micro-mechanisms evaluation.
Carlos Tercero, Masahiro Kojima, Seiichi Ikeda, Katsutoshi Ooe, Toshio Fukuda, Fumihito Arai, Makoto Negoro, Ikuo Takahashi, Guiryong Kwon
ICRA7
2012 Magnetic sugar particles for particulate leaching in fabrication of sheet-like scaffold
abstract
Magnetic field has been used for manipulation of micro-robots; in this research we use it for scaffold fabrication. Magnetic sugar particle (MSP) was used as porogen to control pore size, pore structure and pore density in the scaffold. We studied the influence of the strength of magnetic fields for controlling the coating thickness of unmagnetized MSPs during the fabrication of sheet-like scaffolds. The experimental relationship between magnetic flux density and the thickness of MSP layer was illustrated. Furthermore we investigated the infiltration capacity of poly(L-lactide-co-ε-caprolactone) (PLCL) which was used as scaffold material on the MSP clusters. 5% and 10% PLCL solutions were employed in the experiments. After polymer casting and removal of the sugar template, spherical pores were generated inside scaffold, the thickness evaluation of a single layer scaffold was carried out and the cytocompatibility experiment of NdFeB powder used in fabrication of MSP was confirmed with human umbilical vein endothelial cells.
Chengzhi Hu, Carlos Tercero, Seiichi Ikeda, Toshio Fukuda, Masahiro Nakajima, Fumihito Arai, Makoto Negoro
IROS7
2012 2-D optical encoding of catheter motion and cyber-physical system for technical skills measurement and quantitative evaluation in endovascular surgery
abstract
Quantification of human skills is a challenge for simulator based medical training, particularly for endovascular intervention. For that purpose it is needed to measure different biometric parameters from the user and additionally measure the interaction between endovascular instruments and vasculature models membrane. For that purpose in this research we present an optical sensor for encoding linear and rotational motion of the catheter through the insertion port. Additionally we present two studies for measuring tissue integrity, time to complete a task, reaction time, and wasting motion using two populations of expert and beginner. The optical encoder showed an average error of 0.39mm and 10.78deg. In both studies the presented cyber-physical system is useful to identify the users with qualities closer to the expert among users with low performance.
Hirokatsu Kodama, Carlos Tercero, Katsutoshi Ooe, Chaoyang Shi, Seiichi Ikeda, Toshio Fukuda, Fumihito Arai, Makoto Negoro, Ikuo Takahashi, Guiryong Kwon
IROS8
2012 A cyber-physical system for strain measurements in the cerebral aneurysm models
abstract
For the development of artificial intelligent diagnosis for cerebrovascular intervention, it is desirable to forecast the growth of cerebral aneurysms. In order to achieve such purpose, it is needed to evaluate wall shear stress, strain, pressure, deformation and flow velocity in the aneurysm region. In this research, we focus on in-vitro strain and deformation measurements of cerebral aneurysm models, and propose a cyber-physical system, in which a scaled-up membranous silicone model of cerebral aneurysm was built and integrated with a specialized pump for the pulsatile blood flow simulation, and a vision system was constructed to measure the strain on different regions on the model with pulsatile blood flow circulated inside. Experimental results show that both distance and area strain maxima were larger for the aneurysm neck (0.042 and 0.052), followed by the aneurysm dome (0.023 and 0.04) and then by the main blood vessel section (0.01 and 0.014), which were complemented with computer fluid dynamics simulation for the inclusion of wall shear stress, oscillatory shear index and aneurysm formation index. Medical imaging data of the cerebral aneurysm in 2008 and 2011 was obtained. Diagnosis results have concordance with the aneurysm growth in 2011. The presented measurement method offers an option for measuring strain and deformation to be complementary with computer fluid dynamics and photoelastic stress analysis for advanced diagnostic in the endovascular surgery.
Chaoyang Shi, Masahiro Kojima, Carlos Tercero, Hitomi Anzai, Makoto Ohta, Katsutoshi Ooe, Seiichi Ikeda, Toshio Fukuda, Fumihito Arai, Makoto Negoro, Keiko Irie, Guiryong Kwon
IROS10
2011 Modeling and design of magnetic sugar particles manipulation system for fabrication of vascular scaffold
abstract
This paper reports a magnetic steering method for controlled porogen fabrication of scaffold for blood vessel regeneration. The method described involves generating gradient magnetic field by a combination structure of Helmholtz coils and Maxwell coils to propel particularly prepared magnetic sugar particles (MSPs) moving in fluid environment at desired trajectory and forming a specified 3D shape as templates for particulate leaching. The movement properties of MSP are theoretically analyzed and the corresponding dynamic mechanics model is established. Further the magnetic field distributions inside the combined coils are calculated and optimal control parameters of coils configuration are obtained. Preliminary motion control experiment is also conducted to prove the feasibility of proposed method. The result demonstrates that MSP cluster can be manipulated with average speed of 0.25 mm/s for a cluster of 12 MSPs and 0.116 mm/s for a cluster of 37 MSPs with the proposed coil system and used for improving interconnection of MSP dot patterns.
Chengzhi Hu, Carlos Tercero, Seiichi Ikeda, Toshio Fukuda, Fumihito Arai, Makoto Negoro
IROS6
2010 Photoelastic stress analysis error quantification in vasculature models for robot feedback control
abstract
Real-time and accurate stress calculation in walls of vasculature is desired to provide catheter insertion robots of feedback control without changing the catheter stiffness and lumen. This feedback source has also applications in endovascular surgery simulation for human skills and medical tools evaluation. For that purpose we consider photoelastic effect, as birefringence produced by light retardation relates with the stress inside the photoelastic materials. In this research a polariscope was designed for urethane elastomer vasculature models, the photoelastic coefficient of urethane elastomer was measured, and the camera system was calibrated to quantify and reduce error of the measurement system. An average error of 3.6% was found for the pressure range of 70-189 mmHg inside the model of urethane elastomer, this enables to calculate accurately stress in vasculature models during Human Blood Pressure Simulation (HBPS). That way we will be able to compare in a closed loop stress produced by HBPS and by the catheter motion when manipulated by a robot.
Carlos Tercero, Seiichi Ikeda, Motoki Matsushima, Toshio Fukuda, Makoto Negoro, Ikuo Takahashi
ICRA5
2010 Three-dimensional visualization of photoelastic stress analysis for catheter insertion robot
abstract
It is desirable for endovascular surgery simulation to describe with quantitative data the interaction between the catheter and the blood vessel model wall to make an objective evaluation of the procedure. Photoelastic stress analysis in straight segments of multi-layered models was used for that purpose. In this research we study the error introduced by stress direction on the magnitude measurements, for photoelastic stress analysis. And we propose a scanner for three dimensional visualization of photoelastic stress analysis. As result, we quantified that the maximum contribution of error from stress direction in the first half of the fringe is 2.52% for the stress magnitude measurements. Three-dimensional stress visualization was obtained in segment of straight vasculature with an average error in sample slices of 10.73%, 4.55% and 3.18% for inner pressures of 80, 120 and 160mmHg respectively.
Motoki Matsushima, Carlos Tercero, Seiichi Ikeda, Toshio Fukuda, Makoto Negoro
IROS5
2009 Multi-scale transparent arteriole and capillary vessel models for circulation type blood vessel simulator
abstract
We proposed a fabrication method for multiscale transparent arteriole and capillary vessel models and demonstrated the fabrication of microchannels with circular cross sections ¿10 - 500 ¿m. First, we demonstrated fabrication of ¿10 - 500 ¿m arteriole and capillary vessel block models using photolithography. The circularity of fabricated ¿10, 50, and 500 ¿m microchannels were 84.0%, 61.5%, and 82.3%, respectively. Flow experiments demonstrated that these channels had no leakage. Next, we proposed a fabrication method for ¿100 - 500 ¿m arteriole membrane models, which connect larger membrane models and smaller block models. These models were prepared with grayscale lithography and a wax and PVA (polyvinyl alcohol) mixture material. The proposed approach overcame the brittleness of a previous sacrificial model fabricated by ink jet rapid prototyping. The membrane model had a circular cross section with a channel circularity of 90%. Finally, we succeeded in making transparent membranous and block arteriole model with which we can simulate blood circulation.
Takuma Nakano, Keisuke Yoshida, Seiichi Ikeda, Hiroyuki Oura, Toshio Fukuda, Takehisa Matsuda, Makoto Negoro, Fumihito Arai
IROS7
2008 Fabrication of biodegradable scaffolds by use of self-assembled magnetic sugar particles as a casting template
abstract
Technologies to develop scaffolds with controlled pore layout and porosity have great significance in tissue engineering. As one method of scaffold fabrication, porogen leaching has been commonly used to control pore size, pore structure and porosity in the scaffold. In this paper, we describe a novel approach to fabricate 2D and 3D porous biodegradable scaffolds made of poly(L-lactide-co-ε-caprolactone) by using magnetic sugar particles as porogens. First, ferrite micro/nano particles were encapsulated in sugar microspheres to make them magnetized. After sieving magnetic sugar particles, those diameter-controlled particles were attracted by a magnetic force to form an assembled template for polymer casting. A magnetic field with polka-dot pattern was also utilized to align particles on desired positions. After polymer casting and removal of the sugar template, spherical pores were generated inside scaffold. For future application in vascular tissue engineering, we extended the scaffold fabrication to straight tubular scaffolds by winding 2D porous sheets on sacrificial molds. The biocompatibility of the developed scaffold was confirmed by viable cells after 4-day culture.
Tomoyuki Uchida, Hiroyuki Oura, Seiichi Ikeda, Fumihito Arai, Makoto Negoro, Toshio Fukuda
ICRA5
2007 Patient-Specific Blood Vessel Scaffold for Regenerative Medicine
abstract
In this research, we propose a method to construct an artificial blood vessel scaffold with patient-specific complex 3-dimensional shape and biocompatible porous polymer membrane adapted for cell cultivation, by introducing salt leaching technique into a fabrication technique for patient-specific 3D blood vessel model proposed by authors. In this method, a membranous PVA (polyvinyl alcohol) structure of desired 3-dimensional blood vessel shape was fabricated based on CT data. And the PVA structure was dip coated with polymer solution made by dissolving the Caprolactone (3wt%) and NaCl particle (27wt%) into chloroform (organic solvent), Finally, the NaCl particle and the membranous PVA structure were both eluted from the structure by dissolving these materials under water, and finally a patient-specific blood vessel scaffold with desired 3D vascular shape was constructed. Presented scaffold has the mechanical compliance similar to human blood vessel and provides porous polymer structure appropriate for cell cultivation.
Seiichi Ikeda, Fumihito Arai, Toshio Fukuda, Hiroyuki Oura, Makoto Negoro
ICRA5
2006 Patient-specific Neurovascular Simulator for Evaluating the Performance of Medical Robots and Instruments
abstract
An in vitro patient-specific vascular model, for simulating endovascular intervention is presented. Proposed vascular model reproduces the 3-dimensional vessel lumen structure using CT/MRI information with 13 mum resolution, and it also reproduce the physical characteristics of arterial tissue (elastic modulus and friction coefficient). Furthermore, in this paper, we propose a novel method to evaluate the stress on vasculature which is applied by surgical operations. This method allows quantitatively evaluating 3-dimensional stress conditions in real-time during surgical simulation. Finally, we constructed a comprehensive surgical simulation system, which reproduces whole human aorta structure (with more than Imm inside diameter), reproduce patient-specific pulsatile blood streaming, allowed to evaluate the stress applied to the aorta structure by surgical operations with almost same manner and environment as the practical endovascular intervention. Consequently proposed model, evaluation method and resultant system provides a very valuable platform for evaluating the performance of surgical robots and instruments developed by developers and researchers, and surgical procedures
Shinsuke Ikeda, Fumihito Arai, Toshio Fukuda, Makoto Negoro, Keiko Irie, Ikuo Takahashi
ICRA4
2005 In vitro patient-tailored anatomical model of cerebral artery for evaluating medical robots and systems for intravascular neurosurgery
abstract
In this paper, we propose an in vitro patient-tailored biological model of human cerebral artery, an innovative platform for simulating intravascular neurosurgery to evaluate medical robots and devices. This anatomically accurate model reproduces 3-dimensional configuration of individual arteries with an artery-like thin membranous structure made of silicone elastomer. Its modeling resolution is 13 /spl mu/m. Presented modeling methodology also allows constructing any hollow structure, which is suitable for robot evaluations, making use of CAD. Presented model also reproduces the physical properties of arterial tissue with errors less than 5% (that include elastic modulus, poisson's ratio and frictional coefficient). Thus the cerebral arterial model reproduces not only the behavior of arteries caused by surgical operations, but also the dynamic behavior of surgical robots and devices (e.g. elastic deformation and slip/stick motion). Furthermore, we also propose a novel method that allows developers to evaluate 3-dimensional stress condition on arterial wall, which is caused by surgical operations, by making use of the photoelastic effect. As there are almost no realistic hardware platform enough to fairly evaluate medical robots and devices, it should provide an advanced testing environment for developing robots and other various medical equipments, especially for intravascular neurosurgery.
Seiichi Ikeda, Fumihito Arai, Toshio Fukuda, E. H. Kim, Makoto Negoro, Keiko Irie, Ikuo Takahashi
IROS5
2005 An In Vitro Patient-Tailored Model of Human Cerebral Artery for Simulating Endovascular Intervention
Seiichi Ikeda, Fumihito Arai, Toshio Fukuda, Makoto Negoro, Keiko Irie, Ikuo Takahashi
MICCAI4
2004 An In Vitro Soft Membranous Model of Individual Human Cerebral Artery Reproduced with Visco-elastic Behavior
abstract
An in vitro soft membranous model of individual human cerebral artery reproduced with visco-elastic behavior, for intravascular neurosurgical simulation, preclinical testing, and testing of medical devices, is presented. The presented arterial model is reproduced with soft visco-elastic tissues, existing around the cerebral artery, in addition to the elastic membranous structure of artery, and constructed based on individual information obtained with medical imaging modality. Its human-like constitution realizes surgical simulation accompanied with realistic feel and visco-elastic structural deformation under actual surgical environment. In this report, we present a production methodology for this anatomically accurate cerebral arterial model. With this methodology, arteries with complicated or high aspect structures are precisely reproducible. We also present a technique to improve its visibility against refraction and reflection that take place on surfaces around arterial model. As the presented arterial model is compatible with current major imaging modalities such as computed tomography (CT), magnetic resonance (MR) and transcranial Doppler (TCD), it should be useful for a wide range of applications, such as hemodynamic study and radiological investigations, as well as surgical simulations.
Seiichi Ikeda, Fumihito Arai, Toshio Fukuda, Makoto Negoro
ICRA4
2002 New Catheter Driving Method using Linear Stepping Mechanism for Intravascular Neurosurgery
abstract
Minimum invasive surgery that supports doctors and reduces patient's physical pain has attracted attention. We consider a new intravascular neurosurgery system. There are two problems in intravascular neurosurgery: one is doctor's exposure to x-ray, and another is the lack of skilled doctors. We developed a remote control system by using a master-slave system to solve these problems. In this paper, we describe the development of a new slave device in the master-slave system and construct the new remote control system of catheter operation with safety. To overcome some of the problems encountered on the previous slave device (2000), we develop a new slave device with a disposable structure employing the mechanism of a mechanical pencil for safe operation.
Fumihito Arai, Ryo Fujimura, Toshio Fukuda, Makoto Negoro
ICRA4
2000 Telesurgery System for Intravascular Neurosurgery
Mitsutaka Tanimoto, Fumihito Arai, Toshio Fukuda, Kouichi Itoigawa, Masashi Hashimoto, Ikuo Takahashi, Makoto Negoro
MICCAI7
1999 Force Display Method to Improve Safety in Teleoperation System for Intravascular Neurosurgery
abstract
We have proposed a force display method to improve safety and operativity in a teleoperation system for intravascular neurosurgery. This method consists of two parts. One is improvement of operator's feeling of force feedback by displaying two force sensors' information. The another one is variable impedance characterization, which changes the impedance parameters of the master arm dynamically by reflecting the situation of the slave side. We present some experimental results of this force display method and show the effectiveness of this method.
Mitsutaka Tanimoto, Fumihito Arai, Toshio Fukuda, Makoto Negoro
ICRA4
1998 Augmentation of Safety in Teleoperation System for Intravascular Neurosurgery
abstract
A catheter is one of the medical tools for intravascular neurosurgeries. However, to control a catheter in narrow and complex blood vessels is a very difficult task, so there are not many surgeons who can operate a catheter appropriately. Moreover, these surgeons are exposed to X-ray radiation when they perform the operation. A solution to these problems is a telesurgery system. There are, however, some problems in telesurgery system. In this paper, we focus on the problem of operativity involved in a teleoperation system, and propose a new control strategy to display forces which are measured between a slave arm and the environment based on the variable impedance characterization of the master arm.
Mitsutaka Tanimoto, Fumihito Arai, Toshio Fukuda, Makoto Negoro
ICRA4
1997 Micro force sensor for intravascular neurosurgery
abstract
Minimum invasive surgery using intravascular surgical tools is getting greater attention in the medical field. This technique allows us to reduce physical pain for patients. For example, a catheter is one of the medical tools for endovascular surgeries. The catheter is frequently used for neurosurgical operations. We propose a new type of force sensor for intravascular neurosurgery. This micro force sensor can be installed on the tip of the catheter. We developed a prototype micro force sensor whose diameter is 1.6 mm and length is 12 mm. Using this micro force sensor, we can measure the contact force between the catheter and blood vessels. It is possible to push the blood vessel wall hard when operators use the catheter. So, to express the contact force between catheter and blood vessels is very important for safe operation. In this paper, we show the structure of the micro force sensor and its characteristics.
Mitsutaka Tanimoto, Fumihito Arai, Toshio Fukuda, Hitoshi Iwata, Kouichi Itoigawa, Yasuhiro Gotoh, Masashi Hashimoto, Makoto Negoro
ICRA8
1996 Multimedia tele-surgery using high speed optical fiber network and its application to intravascular neurosurgery - system configuration and computer networked robotic implementation
abstract
We propose a multimedia tele-surgery system for training, diagnosis, and assistance in surgery. To realize this system, a high speed optical fiber network with asynchronous transfer mode (ATM) is used to provide high quality moving pictures. We designed a new teleoperation system based on ATM, which is different from the conventional one that is based on Ethernet. We built a prototype of the virtual simulator system for the intravascular neurosurgery that consists of a 3D-computer graphics simulator and two types of joysticks. The joysticks are used for the controller and force display of catheter head direction, position, and orientation. A visual assistance method is proposed to assist the operator. We performed teleoperation experiments between Nagoya and Tokyo, about 350 km apart from each other, using high speed optical fiber network, and evaluated the effectiveness of the proposed system.
Fumihito Arai, Mitsutaka Tanimoto, Toshio Fukuda, Koji Shimojima, Hideo Matsuura, Makoto Negoro
ICRA6
1996 Micro active guide wire catheter system-Characteristic evaluation, electrical model and operability evaluation of micro active catheter
abstract
We have proposed a new prototype model of micro catheter with active guide wire that has two bending degrees of freedom using ICPF (ionic conducting polymer film) actuator on its front end as the servo actuator. In this paper, the bending characteristics of the micro active catheter (MAC) have been measured by application of electricity in physiological saline solution. By using simulators (whose conditions are similar to those of a body cavity), we also carried out simulation experiments "in vitro" and the contrast experiments of operability between the proposed catheter and conventional guide wire catheter. The experimental results indicate that the proposed MAC is applicable to intracavity operations.
Shuxiang Guo, Toshio Fukuda, Tatsuya Nakamura, Fumihito Arai, Keisuke Oguro, Makoto Negoro
ICRA6
1995 Micro Catheter System with Active with Active Guide Wire
abstract
In this paper, we propose a new prototype model of micro-catheter with active guide wire that has two bending degrees of freedom. The design and fabrication methods of this micro active catheters (MAC) are described. Prototype models are 3Fr, 4Fr, 6Fr (1Fr=1/3 mm) in diameter and consist of catheter tube and active guide wire with ionic conducting polymer film actuator on its front end as the servo actuator. The bending characteristics of the MAC have been measured by application of electricity in physiological saline solution. We also modeled this MAC for characteristic evaluation. Experimental results show that the model of the active catheter is reasonable for practical applications. By using simulators (whose conditions are similar to those of a body cavity), we also carried out simulation experiments "in vitro". The experimental results indicate that the proposed MAC is applicable to intracavity operations.
Shuxiang Guo, Toshio Fukuda, Kazuhiro Kosuge, Fumihito Arai, Keisuke Oguro, Makoto Negoro
ICRA6
1995 Micro active guide wire catheter system
abstract
We propose a new prototype model of micro-active guide wire catheter that has two bending degrees of freedom. The fabrication methods of this micro-active catheters (MAC) are described. Prototype models are 3Fr, 4Fr, 6Fr (1Fr=1 mm) in diameter and consist of catheter tube and active guide wire with ionic conducting polymer film on its front end as the servo actuator. The bending characteristics of the MAC have been measured by application of electricity in physiological saline solution. By using simulators (whose conditions are similar to those of a body cavity), we carried out simulation experiments "in vitro" and the contrast experiments of operability between the proposed catheter and a conventional guide wire catheter. The experimental results indicate that the proposed MAC is applicable to intracavity operations.
Shuxiang Guo, Toshio Fukuda, Fumihito Arai, Keisuke Oguro, Makoto Negoro, Tatsuya Nakamura
IROS (2)5
1994 Micro Active Catheter System with Multi Degrees of Freedom
abstract
In this paper, we propose a new prototype model of serial-parallel type of active micro catheter (MAC) with two bending degrees of freedom. It is 4 Fr, 5 Fr and 6 Fr (1 Fr=1/3 mm) in diameter and consist of 3 active units incorporating SMA wires in lumina as the servo actuator. The bending motion, bending direction and bending angle of the MAC have been measured by application of electricity in air and in physiological saline solution. We also modeled this MAC. Experimental results show that the model of the MAC is reasonable for practical applications. By using simulators (conditions similar to a body cavity), we carried out the simulation experiments of "in vitro" and "in vivo". The experimental results indicate that the proposed MAC is applicable to intracavity operations.>
Toshio Fukuda, Shuxiang Guo, Kazuhiro Kosuge, Fumihito Arai, Makoto Negoro, K. Nakabayashi
ICRA5