Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Yong-San Yoon

dblp:53/5134 · DBLP profile ↗
← Back
8ranked-venue papers
1as first author
0since 2021 · last 2009
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 7 · 1 first-authorSystems, architecture and hardware · 7 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
3 papers
Medical and health informatics · 100%
Artificial intelligence
4 papers
Motion planning and robot control · 54% Robot manipulation · 37% 3D vision · 9%
Computer architecture, parallel and distributed computing, and storage systems
1 paper
Parallel and multicore computing · 50% Embedded and real-time systems · 50%

Topics — the 13 heaviest of 13, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
computer-assisted surgery
0.122003
Robot-assisted femoral stem implantation using an intramedulla gauge · IEEE Trans. Robotics Autom. 2003
The Mechanism and the Registration Method of a Surgical Robot for Hip Arthroplasty · ICRA 2002
Robotics › Robot manipulation › industrial robot
machining robot
0.012003
Robot-assisted femoral stem implantation using an intramedulla gauge · IEEE Trans. Robotics Autom. 2003
Medical and health informatics › surgical robotics
orthopedic surgical robot
0.012003
Robot-assisted femoral stem implantation using an intramedulla gauge · IEEE Trans. Robotics Autom. 2003
Medical and health informatics
surgical robotics
0.012002
The Mechanism and the Registration Method of a Surgical Robot for Hip Arthroplasty · ICRA 2002
Medical and health informatics › surgical robotics
robot-assisted surgery
0.012001
Accurate Femoral Canal Shaping in Total Hip Arthroplasty using a Mini-Robot · ICRA 2001
Robotics › Motion planning and robot control › robot dynamics
dynamic simulation
0.011998
Real-Time Dynamic Simulation of Quadruped Using Modified Velocity Transformation · ICRA 1998
Robotics › Motion planning and robot control › robot control
redundant manipulator control
0.011997
Stabilization constraint method for torque optimization of a redundant manipulator · ICRA 1997
Robotics › Motion planning and robot control
robot control
0.011997
Stabilization constraint method for torque optimization of a redundant manipulator · ICRA 1997
Robotics › Motion planning and robot control › robot control › optimization-based control
torque optimization
0.011997
Stabilization constraint method for torque optimization of a redundant manipulator · ICRA 1997
Computer vision › 3D vision › geometric estimation
registration
0.012003
Robot-assisted femoral stem implantation using an intramedulla gauge · IEEE Trans. Robotics Autom. 2003
Robotics › Robot manipulation › medical robotics
surgical robotics
0.012001
Accurate Femoral Canal Shaping in Total Hip Arthroplasty using a Mini-Robot · ICRA 2001
Parallel and multicore computing
parallel computing
0.011998
Real-Time Dynamic Simulation of Quadruped Using Modified Velocity Transformation · ICRA 1998
Embedded and real-time systems
real-time simulation
0.011998
Real-Time Dynamic Simulation of Quadruped Using Modified Velocity Transformation · ICRA 1998

Methods — techniques the papers use, named apart from their topics

registration gauge · 0.1mini-robot · 0.1velocity transformation · 0.0recursive calculation · 0.0parallel computation · 0.0preoperative planning · 0.0gauge-based registration · 0.0linear programming · 0.0infinity-norm minimization · 0.0
YearPublicationVenuePosition
2009 Behavior planning of an unmanned ground vehicle with actively articulated suspension to negotiate geometric obstacles
abstract
The behavior control method was usually adapted for controlling the suspension configuration which determines the traversability of the UGV with actively articulated suspension. In this paper, we proposed a method of configuration planning of the suspension without any detail geometric data of terrain. The terrain was estimated by the traces of each wheel and the behavior plans for the desired upper level behavior were set up against the constraints of the terrain. Also, an optimal suspension configuration was calculated based on the quasi-static stability and power consumption, and plans for the suspension behavior were made. Validity of the proposed method was checked by simulation using some off-the-shelf programs, and showed that the behavior planning without geometric features of terrain and simplification of the behavior planning for obstacle negotiation were possible.
Kyeong Bin Lim, Sukhoon Park, Suengwoo Kim, Jae Muk Jeong, Yong-San Yoon
IROS5
2003 In vitro study using cadavers for evaluation of a bone-mountable surgical robot system
abstract
This paper describes a bone-mountable surgical robot system for hip surgery and its in vitro experiments with cadavers. The system eliminates the need for obtaining CT scan data by adopting gauge-based, bone-mounting registration method and is designed to replace only the broaching procedure, which is known to be the most error-prone procedure in the manual surgery. The performance of this system is evaluated with specimen of six human cadavers. X-ray images and photographed image of femurs are utilized for measuring the difference between the implant and the anatomical axes. As this deviation implies how the gait pattern of the operated patient may be influenced by the surgery, the amount of deviation is used as the indicative of system performance. The nominal differences of anteversion angle, valgus-varus angle, and flexion-extension angle are 0.02/spl plusmn/2.73/spl deg/, 0.98 /spl plusmn/0.39/spl deg/ and 0.51/spl plusmn/0.87/spl deg/, respectively. In case of the change in leg length after the surgery, the nominal error is -0.88/spl plusmn/1.26 mm. Experimental results show that the performance of the developed system is comparable to other surgical robots that use preoperative planning with CT scan data.
Seong-Young Ko, Jong-Ha Chung, Jonathan Kim, Dong-Soo Kwon, Jung-Ju Lee, Yong-San Yoon, Choong-Hee Won
IROS6
2003 Robot-assisted femoral stem implantation using an intramedulla gauge
abstract
This paper presents a gauge-based registration method, a femur-mountable robot for hip arthroplasty named ARTHROBOT, and the surgery procedure using this system. In the gauge-based registration, a reamer-shaped gauge is inserted into the femoral medulla for relative positional information of the femur to the robot. A mounting frame and a minirobot are then mounted on the patient's femur for accurate machining. This gauge-based registration method drastically reduces the processes in preoperative planning by eliminating the need of computer tomography scanning or other image processing methods, compared to other robotic systems that are used for hip surgery. Also, this surgical system reduces damage to the femur because only the metaphyseal region of the femoral canal needs to be machined, while leaving the diaphyseal hard bone untouched. Experiments were performed on 18 composite bones and 12 pig bones. In the composite bone group, orientation (anterversion, varus/valgus and flexion/extension) errors were made at 0.13/spl deg//spl plusmn/0.77/spl deg/, 0.14/spl deg//spl plusmn/0.38/spl deg/, and -0.27/spl deg//spl plusmn/0.33/spl deg/, and the maximum position error was at 1.00 mm. In the pig bone group, orientation errors were made at -0.03/spl deg//spl plusmn/0.65/spl deg/, 0.31/spl plusmn/0.27/spl deg/, and -0.36/spl deg//spl plusmn/0.36/spl deg/, and the maximum position error was at 1.12 mm. Also, 93% of the gaps between the bone and the implant surface were under 0.25 mm. The developed system shows sufficient machining accuracy and precision for clinical application.
Jong-Ha Chung, Seong-Young Ko, Dong-Soo Kwon, Jung-Ju Lee, Yong-San Yoon, Choong-Hee Won
IEEE Trans. Robotics Autom.5
2002 The Mechanism and the Registration Method of a Surgical Robot for Hip Arthroplasty
abstract
This paper presents the mechanism and surgical method for ARTHROBOT, a new surgical robot for hip arthroplasty. The robot is femur-mountable and capable of 4-DOF motion. It uses a new gauge-based registration method that utilizes measuring instrument consisting of a reamer-shaped block gauge and a distance-measuring device. This gauge-based registration method drastically reduces the processes in the preoperative planning by eliminating the need of inserting fiducial markers or CT scanning. From the preliminary performance evaluation, it is shown to have less than 0.3 mm machining error, which seems to be sufficiently accurate for clinical application. Since the system has low operating cost and is compatible to the conventional manual surgery, it is expected to be easily adaptable to surgical needs and practices in the operating room.
Dong-Soo Kwon, Jung-Ju Lee, Yong-San Yoon, Seong-Young Ko, Jonathan Kim, Jong-Ha Chung, Chung-Hee Won, Jong-Hwa Kim
ICRA3
2001 Accurate Femoral Canal Shaping in Total Hip Arthroplasty using a Mini-Robot
abstract
We propose a greatly simplified femoral canal shaping method for robot-assisted total hip replacement surgery that requires neither CT/MRI imaging nor insertion of fiducial markers before surgery. A reamer-shaped registration gauge is inserted into the femoral canal and used to position a base for a robot that is mounted on the top of the femur and used to prepare the femoral canal. In a study using 5 fresh cadavers, the average registration error for selected points near the surface of the femoral cavity was 0.59 mm; this is comparable to the errors reported for the geometry-based registration methods.
Yong-San Yoon, Jung-Ju Lee, Dong-Soo Kwon, J. H. Won, Antony J. Hodgson, Thomas Oxland
ICRA1
2001 ARTHROBOT : a new surgical robot system for total hip arthroplasty
abstract
This paper presents mechanisms and control methods of a new surgery robot for total hip arthroplasty (THA). To minimize the disadvantages of the conventional registration method, a new gauge-based registration method has been proposed, and a 3-DOF robot has been developed that can be mounted on a femur The proposed surgical robot can operate along a pre-programmed path autonomously, in addition to allowing a surgeon to directly control the motion of the surgical robot with their experience and judgment during an operation. For this purpose, a master is attached to the surgical robot and admittance display is used in control. ARTHROBOT this new arthroplastic surgical robot system, is expected to be adaptable to surgical needs and practice in the operating room.
Dong-Soo Kwon, Yong-San Yoon, Jung-Ju Lee, Seong-Young Ko, Kwan-Hoe Huh, Jong-Ha Chung, Young-Bae Park, Chung-Hee Won
IROS2
1998 Real-Time Dynamic Simulation of Quadruped Using Modified Velocity Transformation
abstract
The dynamic formulation using the velocity transformation modified to make it more efficient with the recursive calculations and removal of trivial calculations is applied to the real-time simulation of the quadruped. The proposed method turned out to be an O(N) algorithm for parallel structures and an O(N/sup 3/) algorithm for serial structures from the fact that the computation for the simulation of the quadruped is proportional to the number of legs and the cube of the DOF of a leg. Thus it may be most profitable for the quadruped model with decoupled tree structure because it has been demonstrated that the best O(N/sup 3/) algorithms are faster than the best O(N) algorithms for N<10. The results also show that the real-time simulation can be achieved on a personal workstation with the application of parallel computation.
Kwang-Pyo Lee, Tae-Wan Koo, Yong-San Yoon
ICRA3
1997 Stabilization constraint method for torque optimization of a redundant manipulator
abstract
The minimization of the joint torques based on the /spl infin/-norm is proposed for the dynamic control of a kinematically redundant manipulator. The /spl infin/-norm is preferred to the 2-norm in the minimization of the joint torques since the torques of the actuators are limited by their maximum values in magnitudes. To obtain the minimum /spl infin/-norm torque solution, we devised a new method that uses the acceleration polyhedron representing the end-effector's acceleration capability. Usually the torque minimization has the instability problem for the long trajectories of the end-effector. To suppress this instability problem, an inequality constraint, named the stabilization constraint, is developed from geometrical relations between the desired end-effector acceleration and the acceleration polyhedron. The minimization of the /spl infin/-norm of the joint torques subject to the stabilization constraint is shown to improve the performances through the simulations of a 3-link planar redundant manipulator.
Ick-Chan Shim, Yong-San Yoon
ICRA2