Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Charles F. Babbs

dblp:57/3902 · DBLP profile ↗
← Back
4ranked-venue papers
0as first author
0since 2021 · last 2001
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Graphics, computer vision, multimedia, augmented reality and games · 2Human-computer interaction and ubiquitous computing · 1Applied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer graphics and multimedia
1 paper
Multimedia analysis and retrieval · 50% Image and video processing · 50%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Artificial intelligence
1 paper
Image recognition and object detection · 100%

Topics — the 3 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › medical imaging
medical image analysis
0.012001
Multiresolution detection of spiculated lesions in digital mammograms · IEEE Trans. Image Process. 2001
Multimedia analysis and retrieval › image analysis
multiresolution image analysis
0.012001
Multiresolution detection of spiculated lesions in digital mammograms · IEEE Trans. Image Process. 2001
Image and video processing
wavelet transform
0.012001
Multiresolution detection of spiculated lesions in digital mammograms · IEEE Trans. Image Process. 2001

Methods — techniques the papers use, named apart from their topics

multiresolution analysis · 0.1feature extraction · 0.1binary tree classifier · 0.12-d wavelet transform · 0.1
YearPublicationVenuePosition
2001 Multiresolution detection of spiculated lesions in digital mammograms
abstract
We present a novel multiresolution scheme for the detection of spiculated lesions in digital mammograms. First, a multiresolution representation of the original mammogram is obtained using a linear phase nonseparable two-dimensional (2-D) wavelet transform. A set of features is then extracted at each resolution in the wavelet pyramid for every pixel. This approach addresses the difficulty of predetermining the neighborhood size for feature extraction to characterize objects that may appear in different sizes. Detection is performed from the coarsest resolution to the finest resolution using a binary tree classifier. This top-down approach requires less computation by starting with the least amount of data and propagating detection results to finer resolutions. Experimental results using the MIAS image database have shown that this algorithm is capable of detecting spiculated lesions of very different sizes at low false positive rates.
Charles F. Babbs, Edward J. Delp
IEEE Trans. Image Process.2
1998 Normal Mammogram Analysis and Recognition
abstract
Presents a novel approach to the problem of computer aided analysis of digital mammograms for breast cancer detection: namely, the development of algorithms to recognize unequivocally normal mammograms. First, the authors eliminate amorphous "clouds" or "blobs" in mammograms produced by normal glandular tissue of varying density using local average subtraction. Then the authors identify and remove normal connective tissue markings based on a set of specially designed line detectors. Any abnormality that may exist in the mammogram is therefore enhanced in the residual image, which makes the decision regarding the normality of the mammogram, much easier.
Charles F. Babbs, Edward J. Delp
ICIP (1)2
1996 Issues in the design of studies to test the effectiveness of stereo imaging
abstract
Recently, there has been a great increase in interest in using three dimensional stereoscopic displays to provide viewers with realistic 3D views of objects of interest. Some applications where stereoscopic displays are becoming popular include medical visualization, visualization of meteorological data, and various virtual reality applications. To quantify the effectiveness of stereoscopic systems over conventional monoscopic systems, well-designed experiments and data analysis methods are necessary. This task requires the combined effort of application scientists and experts in experimental design. Lack of interdisciplinary collaboration is a primary weakness of many stereoscopic display studies, resulting in the neglect of many important but subtle experimental issues. In this paper, we discuss specific issues that arise in the design of studies to determine the effectiveness of digital stereo imagery. Issues concerning statistical analysis of the experimental data are also discussed. References to related literature from engineering, computer graphics, and psychophysics are given. The issues developed herein provide a guideline for the design of studies to compare observer performance when using different imaging modalities.
Jean Hsu, Zygmunt Pizlo, David M. Chelberg, Charles F. Babbs, Edward J. Delp
IEEE Trans. Syst. Man Cybern. Part A4
1995 Preclinical ROC studies of digital stereomammography
abstract
Reports the diagnostic performance of observers in detecting abnormalities in computer-generated mammogram-like images. A mathematical model of the human breast is defined in which breast tissues are simulated by spheres of different sizes and densities. Images are generated by casting rays from a specified source, through the model, and onto an image plane. Observer performance when using two viewing modalities (stereo versus mono) is compared. In the stereo viewing mode, images are presented to the observer (wearing liquid-crystal display glasses), such that the left eye sees the left image only and the right eye sees the right image only. In this way, the images can be fused by the observer to obtain a sense of depth. In the mono viewing mode, identical images are presented to the left and right eyes so that no binocular disparities will be produced by the images. Observer response data are evaluated using receiver operating characteristic (ROC) analysis to characterize any difference in detectability of abnormalities (in either the density or the arrangement of simulated tissue densities) using the two viewing modes. The authors' experimental results indicate the clear superiority of stereo viewing for detection of arrangement abnormalities. For detection of density abnormalities, the performance of the two viewing modes is similar. These preliminary results suggest that stereomammography may permit easier detection of certain tissue abnormalities, perhaps providing a route to earlier tumor detection in cases of breast cancer.
Jean Hsu, David M. Chelberg, Charles F. Babbs, Zygmunt Pizlo, Edward J. Delp
IEEE Trans. Medical Imaging3