Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Nicolaos A. Mouravliansky

dblp:60/1841 · DBLP profile ↗
← Back
10ranked-venue papers
1as first author
0since 2021 · last 2006
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 6Systems, architecture and hardware · 3Graphics, computer vision, multimedia, augmented reality and games · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Computer graphics and multimedia
1 paper
Visualization and visual analytics · 50% Virtual and augmented reality · 50%

Topics — the 3 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › clinical decision-making
treatment planning
0.012002
In silico radiation oncology: combining novel simulation algorithms with current visualization techniques · Proc. IEEE 2002
Visualization and visual analytics
scientific visualization
0.012002
In silico radiation oncology: combining novel simulation algorithms with current visualization techniques · Proc. IEEE 2002
Virtual and augmented reality › immersive visualization
virtual reality visualization
0.012002
In silico radiation oncology: combining novel simulation algorithms with current visualization techniques · Proc. IEEE 2002

Methods — techniques the papers use, named apart from their topics

three-dimensional simulation · 0.1mathematical modeling · 0.1
YearPublicationVenuePosition
2006 Image Registration Based on Lifting Process: An Application to Digital Subtraction Radiography
abstract
In this paper, a digital subtraction radiology scheme is presented based on a new method for the automatic registration of dental radiographs acquired with or without rigorous a priori standardization. The scheme is comprised of an automatic registration method and a subtraction process. The proposed registration method can be considered as an object-based registration method without imposing the prerequisite of image segmentation in order to detect the boundary of the objects of interest or the automatic detection of matching landmarks. This is achieved by augmenting the dimensionality of the problem from two-dimensional gray-level matching to three-dimensional surface matching using the process of lifting in combination with a surface-matching technique. The pseudo three-dimensional affine transformation that matches the lifted images incorporates advantageous characteristics including spatial alignment of the surfaces, anisotropic correction of brightness/contrast differences, and stable convergence of the similarity function to its optimal value. The performance of the proposed automatic registration method is assessed against a manual method based on the projective transformation. The qualitative and quantitative assessments of the experiments have shown advantageous performance of the proposed automatic registration method against the manual one. Finally, the proposed registration method has been further improved in terms of execution time by the implementation of a surface decimation process.
George K. Matsopoulos, Nicolaos A. Mouravliansky, Kostas Delibasis, K. Grondahl, H.-G. Grondahl
IEEE Trans. Inf. Technol. Biomed.2
2005 Thoracic non-rigid registration combining self-organizing maps and radial basis functions
George K. Matsopoulos, Nicolaos A. Mouravliansky, Kostas Delibasis, Vassilis Kouloulias
Medical Image Anal.2
2004 Combining a morphological interpolation approach with a surface reconstruction method for the 3-D representation of tomographic data
Nicolaos A. Mouravliansky, George K. Matsopoulos, Kostas Delibasis, Konstantina S. Nikita
J. Vis. Commun. Image Represent.1
2004 Multimodal registration of retinal images using self organizing maps
abstract
In this paper, an automatic method for registering multimodal retinal images is presented. The method consists of three steps: the vessel centerline detection and extraction of bifurcation points only in the reference image, the automatic correspondence of bifurcation points in the two images using a novel implementation of the self organizing maps and the extraction of the parameters of the affine transform using the previously obtained correspondences. The proposed registration algorithm was tested on 24 multimodal retinal pairs and the obtained results show an advantageous performance in terms of accuracy with respect to the manual registration.
George K. Matsopoulos, Nicolaos A. Mouravliansky, Kostas Delibasis
IEEE Trans. Medical Imaging3
2002 In silico radiation oncology: combining novel simulation algorithms with current visualization techniques
abstract
The concept of in silica radiation oncology is clarified in this paper. A brief literature review points out the principal domains in which experimental, mathematical, and three-dimensional (3-D) computer simulation models of tumor growth and response to radiation therapy have been developed. Two paradigms of 3-D simulation models developed by our research group are concisely presented. The first one refers to the in vitro development and radiation response of a tumor spheroid whereas the second one refers to the fractionated radiation response of a clinical tumor in vivo based on the patient's imaging data. In each case, a description of the salient points of the corresponding algorithms and the visualization techniques used takes place. Specific applications of the models to experimental and clinical cases are described and the behavior of the models is two- and three-dimensionally visualized by using virtual reality techniques. Good qualitative agreement with experimental and clinical observations strengthens the applicability of the models to real situations. A protocol for further testing and adaptation is outlined. Therefore, an advanced integrated patient specific decision support and spatio-temporal treatment planning system is expected to emerge after the completion of the necessary experimental tests and clinical evaluation.
Georgios S. Stamatakos, Dimitra D. Dionysiou, Evangelia I. Zacharaki, Nicolaos A. Mouravliansky, Konstantina S. Nikita, Nikolaos K. Uzunoglu
Proc. IEEE4
2001 Modeling tumor growth and irradiation response in vitro-a combination of high-performance computing and Web-based technologies including VRML visualization
abstract
A simplified three-dimensional Monte Carlo simulation model of in vitro tumor growth and response to fractionated radiotherapeutic schemes is presented in this paper. The paper aims at both the optimization of radiotherapy and the provision of insight into the biological mechanisms involved in tumor development. The basics of the modeling philosophy of Duechting have been adopted and substantially extended. The main processes taken into account by the model are the transitions between the cell cycle phases, the diffusion of oxygen and glucose, and the cell survival probabilities following irradiation. Specific algorithms satisfactorily describing tumor expansion and shrinkage have been applied, whereas a novel approach to the modeling of the tumor response to irradiation has been proposed and implemented. High-performance computing systems in conjunction with Web technologies have coped with the particularly high computer memory and processing demands. A visualization system based on the MATLAB software package and the virtual-reality modeling language has been employed. Its utilization has led to a spectacular representation of both the external surface and the internal structure of the developing tumor. The simulation model has been applied to the special case of small cell lung carcinoma in vitro irradiated according to both the standard and accelerated fractionation schemes. A good qualitative agreement with laboratory experience has been observed in all cases. Accordingly, the hypothesis that advanced simulation models for the in silico testing of tumor irradiation schemes could substantially enhance the radiotherapy optimization process is further strengthened. Currently, our group is investigating extensions of the presented algorithms so that efficient descriptions of the corresponding clinical (in vivo) cases are achieved.
Georgios S. Stamatakos, Evangelia I. Zacharaki, Mersini Makropoulou, Nicolaos A. Mouravliansky, Andy Marsh, Konstantina S. Nikita, Nikolaos K. Uzunoglu
IEEE Trans. Inf. Technol. Biomed.4
1999 MR functional cardiac imaging: Segmentation, measurement and WWW based visualisation of 4D data
Kostas Delibasis, Nicolaos A. Mouravliansky, George K. Matsopoulos, Konstantina S. Nikita, Andy Marsh
Future Gener. Comput. Syst.2
1999 Automatic retinal image registration scheme using global optimization techniques
abstract
Retinal image registration is commonly required in order to combine the complementary information in different retinal modalities. In this paper, a new automatic scheme to register retinal images is presented and is currently tested in a clinical environment. The scheme considers the suitability and efficiency of different image transformation models and function optimization techniques, following an initial preprocessing stage. Three different transformation models--affine, bilinear and projective--as well as three optimization techniques--downhill simplex method, simulated annealing and genetic algorithms--are investigated and compared in terms of accuracy and efficiency. The registration of 26 pairs of Fluoroscein Angiography and Indocyanine Green Chorioangiography images with the corresponding Red-Free retinal images, showed the superiority of combining genetic algorithms with the affine and bilinear transformation models. A comparative study of the proposed automatic registration scheme against the manual method, commonly used in the clinical practice, is finally presented showing the advantage of the proposed automatic scheme in terms of accuracy and consistency.
George K. Matsopoulos, Nicolaos A. Mouravliansky, Kostas Delibasis, Konstantina S. Nikita
IEEE Trans. Inf. Technol. Biomed.2
1998 From raw data to WWW compatible visualization and manipulation: Imaging human electric potentials
Kostas Delibasis, Christian Michael, Nicolaos A. Mouravliansky, K. Papaodysseas
Future Gener. Comput. Syst.3
1998 A simplified simulation model and virtual reality visualization of tumour growth in vitro
Georgios S. Stamatakos, Nikolaos K. Uzunoglu, Kostas Delibasis, Mersini Makropoulou, Nicolaos A. Mouravliansky, Andy Marsh
Future Gener. Comput. Syst.5