Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Ulrich Seibold

dblp:60/6288 · DBLP profile ↗
← Back
4ranked-venue papers
1as first author
0since 2021 · last 2013
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 1 first-authorSystems, architecture and hardware · 4 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Robot manipulation · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 8 heaviest of 8, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › medical robotics › surgical robotics
minimally invasive surgery
0.112009
The DLR MiroSurge - A robotic system for surgery · ICRA 2009
Robotics › Robot manipulation › medical robotics
surgical robotics
0.112009
The DLR MiroSurge - A robotic system for surgery · ICRA 2009
Robotics › Robot manipulation
force sensing
0.112005
Prototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability · ICRA 2005
Robotics › Robot manipulation › force sensing
six-axis force sensor
0.112005
Prototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability · ICRA 2005
Medical and health informatics › surgical robotics
minimally invasive robotic surgery
0.112005
Prototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability · ICRA 2005
Medical and health informatics
surgical robotics
0.112005
Prototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability · ICRA 2005
Robotics › Robot manipulation
soft robotics
0.012009
The DLR MiroSurge - A robotic system for surgery · ICRA 2009
Robotics › Robot manipulation › medical robotics
surgical instrument design
0.012005
Prototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability · ICRA 2005

Methods — techniques the papers use, named apart from their topics

sensor integration · 0.1teleoperation · 0.1soft robotics · 0.1
YearPublicationVenuePosition
2013 A fiberoptic force-torque-sensor for minimally invasive robotic surgery
abstract
This document presents the design of a 6-degree of freedom fiberoptic force-torque-sensor for integration in instruments for minimally invasive robotic surgery. The measuring system based on fiber Bragg gratings as well as the calibration procedure are explained. Measurement properties of the sensor are verified in a test setup.
Robert Haslinger, Patrick Leyendecker, Ulrich Seibold
ICRA3
2010 MICA - A new generation of versatile instruments in robotic surgery
abstract
Robotic surgery systems are highly complex and expensive pieces of equipment. Demands for lower cost of care can be met if these systems are employable in a flexible manner for a large variety of procedures. To protect the initial investment the capabilities of a robotic system need to be expandable as new tasks arise. To oblige the needs of future robotic support in hospitals, the German Aerospace Center (DLR) has developed the versatile robotic system MiroSurge for medical applications. This paper presents a 3 DoF instrument for Minimally Invasive Robotic Surgery which is mounted to the hollow wrist of the DLR MIRO robot arm. The MICA instrument consists of a versatile drive train and a detachable task specific tool with its tool interface, shaft, 2 DoF wrist, 7 DoF force/torque sensor and the actuated functional end. With the current cable-driven tool, gripping and manipulation forces of above 10 N are feasible and dynamics is high enough for surgery at the beating heart.
Sophie Thielmann, Ulrich Seibold, Robert Haslinger, Georg Passig, Thomas Bahls, Stefan Jörg, Mathias Nickl, Alexander Nothhelfer, Ulrich Hagn, Gerd Hirzinger
IROS2
2009 The DLR MiroSurge - A robotic system for surgery
abstract
This video presents the in-house developed DLR MiroSurge robotic system for surgery. As shown, the system is suitable for both minimally invasive and open surgery. Essential part of the system is the MIRO robot: The soft robotics feature enables intuitive interaction with the robot.
Rainer Konietschke, Ulrich Hagn, Mathias Nickl, Stefan Jörg, Andreas Tobergte, Georg Passig, Ulrich Seibold, Luc Le Tien, Bernhard Kübler, Martin Gröger, Florian A. Fröhlich, Christian Rink, Alin Albu-Schäffer, Markus Grebenstein, Tobias Ortmaier, Gerd Hirzinger
ICRA7
2005 Prototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability
abstract
Minimally invasive surgery (MIS) challenges the surgeon’s skills due to his separation from the operation area which can only be reached with long instruments. To overcome these drawbacks, minimally invasive robotic surgery (MIRS) plays an important role. This paper describes the development of actuated and sensorized instruments for minimally invasive robotic surgery which help to increase the surgeon’s immersion and dexterity.
Ulrich Seibold, Bernhard Kübler, Gerd Hirzinger
ICRA1