Demo Data from EDBT 2026 / reviewers in the wild / expert
Brian C. Becker
dblp:62/4602
· DBLP profile ↗
8ranked-venue papers
5as first author
1since 2021 · last 2021
0000-0002-2733-2676ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 7 · 5 first-author · 1 since 2021Systems, architecture and hardware · 5 · 5 first-authorApplied, interdisciplinary, general and emerging computing · 2Human-computer interaction and ubiquitous computing · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
4 papers |
Robot manipulation · 62% Motion planning and robot control · 38% | |
| Interdisciplinary, comprehensive, and emerging computing
4 papers |
Medical and health informatics · 100% | |
| Human-computer interaction and pervasive computing
1 paper |
Health and well-being technologies · 100% | |
| Computer graphics and multimedia
1 paper |
Image and video processing · 100% |
Topics — the 10 heaviest of 12, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation › medical robotics
tremor cancellation |
0.4 | 4 | 2012 | Micron: An Actively Stabilized Handheld Tool for Microsurgery · IEEE Trans. Robotics 2012 Handheld micromanipulation with vision-based virtual fixtures · ICRA 2011 Active guidance of a handheld micromanipulator using visual servoing · ICRA 2009 |
Robotics › Robot manipulation
micromanipulation |
0.3 | 3 | 2012 | Handheld micromanipulation with vision-based virtual fixtures · ICRA 2011 Active guidance of a handheld micromanipulator using visual servoing · ICRA 2009 Vision-based retinal membrane peeling with a handheld robot · ICRA 2012 |
Robotics › Motion planning and robot control › robot control › stabilization control
active stabilization |
0.1 | 1 | 2012 | Micron: An Actively Stabilized Handheld Tool for Microsurgery · IEEE Trans. Robotics 2012 |
Medical and health informatics › ophthalmology
retinal surgery |
0.1 | 1 | 2012 | Vision-based retinal membrane peeling with a handheld robot · ICRA 2012 |
Health and well-being technologies
microsurgery |
0.1 | 1 | 2012 | Micron: An Actively Stabilized Handheld Tool for Microsurgery · IEEE Trans. Robotics 2012 |
Robotics › Motion planning and robot control
virtual fixtures |
0.1 | 1 | 2011 | Handheld micromanipulation with vision-based virtual fixtures · ICRA 2011 |
Robotics › Motion planning and robot control › robot control › sensor-based control
visual servoing |
0.1 | 1 | 2009 | Active guidance of a handheld micromanipulator using visual servoing · ICRA 2009 |
Medical and health informatics
microsurgery |
0.1 | 2 | 2011 | Handheld micromanipulation with vision-based virtual fixtures · ICRA 2011 Active guidance of a handheld micromanipulator using visual servoing · ICRA 2009 |
Image and video processing
image registration |
0.0 | 1 | 2013 | Real-time retinal vessel mapping and localization for intraocular surgery · ICRA 2013 |
Image and video processing › image fusion
temporal fusion |
0.0 | 1 | 2013 | Real-time retinal vessel mapping and localization for intraocular surgery · ICRA 2013 |
Methods — techniques the papers use, named apart from their topics
motion scaling · 0.7vessel detection · 0.3image registration · 0.3velocity limiting · 0.3stereo vision · 0.3piezoelectric actuation · 0.3optical position measurement · 0.3control filter design · 0.3vision-based virtual fixtures · 0.2visual servoing · 0.2
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2021 | MultiXNet: Multiclass Multistage Multimodal Motion PredictionabstractOne of the critical pieces of the self-driving puzzle is understanding the surroundings of a self-driving vehicle (SDV) and predicting how these surroundings will change in the near future. To address this task we propose MultiXNet, an end-to-end approach for detection and motion prediction based directly on lidar sensor data. This approach builds on prior work by handling multiple classes of traffic actors, adding a jointly trained second-stage trajectory refinement step, and producing a multimodal probability distribution over future actor motion that includes both multiple discrete traffic behaviors and calibrated continuous position uncertainties. The method was evaluated on large-scale, real-world data collected by a fleet of SDV s in several cities, with the results indicating that it outperforms existing state-of-the-art approaches. Nemanja Djuric, Henggang Cui, Zhaoen Su, Shangxuan Wu, Huahua Wang, Fang-Chieh Chou, Luisa San Martin, Alyssa Dayan, Sidney Zhang, Brian C. Becker, Gregory P. Meyer, Carlos Vallespi-Gonzalez, Carl Wellington |
IV | 13 |
| 2013 | Real-time retinal vessel mapping and localization for intraocular surgeryabstractComputer-aided intraocular surgery requires precise, real-time knowledge of the vasculature during retinal procedures such as laser photocoagulation or vessel cannulation. Because vitreoretinal surgeons manipulate retinal structures on the back of the eye through ports in the sclera, voluntary and involuntary tool motion rotates the eye in the socket and causes movement to the microscope view of the retina. The dynamic nature of the surgical workspace during intraocular surgery makes mapping, tracking, and localizing vasculature in real time a challenge. We present an approach that both maps and localizes retinal vessels by temporally fusing and registering individual-frame vessel detections. On video of porcine and human retina, we demonstrate real-time performance, rapid convergence, and robustness to variable illumination and tool occlusion. Brian C. Becker, Cameron N. Riviere |
ICRA | 1 |
| 2012 | Inexpensive monocular pico-projector-based augmented reality display for surgical microscopeabstractThis paper describes an inexpensive pico-projector-based augmented reality (AR) display for a surgical microscope. The system is designed for use with Micron, an active handheld surgical tool that cancels hand tremor of surgeons to improve microsurgical accuracy. Using the AR display, virtual cues can be injected into the microscope view to track the movement of the tip of Micron, show the desired position, and indicate the position error. Cues can be used to maintain high performance by helping the surgeon to avoid drifting out of the workspace of the instrument. Also, boundary information such as the view range of the cameras that record surgical procedures can be displayed to tell surgeons the operation area. Furthermore, numerical, textual, or graphical information can be displayed, showing such things as tool tip depth in the work space and on/off status of the canceling function of Micron. Brian C. Becker, Cameron N. Riviere |
CBMS | 2 |
| 2012 | Vision-based retinal membrane peeling with a handheld robotabstractPeeling delicate retinal membranes, which are often less than 5 µm thick, is one of the most challenging retinal surgeries. Preventing rips and tears caused by tremor and excessive force can decrease injury and reduce the need for follow up surgeries. We propose the use of a fully handheld microsurgical robot to suppress tremor while enforcing helpful constraints on the motion of the tool. Using stereo vision and tracking algorithms, the robot activates motion-scaled behavior as the tip reaches the surface, providing finer control during the critical step of engaging the membrane edge. A hard virtual fixture just below the surface limits the total downward force that can be applied. Furthermore, velocity limiting during the peeling helps the surgeon maintain a smooth, constant force while lifting and delaminating the membrane. On a phantom consisting of plastic wrap stretched across a rubber slide, we demonstrate our approach reduces maximum force by 40-70%. Brian C. Becker, Robert A. MacLachlan, Louis A. Lobes Jr., Cameron N. Riviere |
ICRA | 1 |
| 2012 | Micron: An Actively Stabilized Handheld Tool for MicrosurgeryabstractWe describe the design and performance of a hand-held actively stabilized tool to increase accuracy in micro-surgery or other precision manipulation. It removes involuntary motion such as tremor by actuating the tip to counteract the effect of the undesired handle motion. The key components are a three-degree-of-freedom piezoelectric manipulator that has 400 μm range of motion, 1 N force capability, and bandwidth over 100 Hz, and an optical position measurement subsystem that acquires the tool pose with 4 μm resolution at 2000 samples/s. A control system using these components attenuates hand motion by at least 15 dB (a fivefold reduction). By considering the effect of the frequency response of Micron on the human visual feedback loop, we have developed a filter that reduces unintentional motion, yet preserves intuitive eye-hand coordination. We evaluated the effectiveness of Micron by measuring the accuracy of the human/machine system in three simple manipulation tasks. Handheld testing by three eye surgeons and three non-surgeons showed a reduction in position error of between 32% and 52%, depending on the error metric. Robert A. MacLachlan, Brian C. Becker, Jaime Cuevas Tabarés, Gregg Podnar, Louis A. Lobes Jr., Cameron N. Riviere |
IEEE Trans. Robotics | 2 |
| 2011 | Handheld micromanipulation with vision-based virtual fixturesabstractPrecise movement during micromanipulation becomes difficult in submillimeter workspaces, largely due to the destabilizing influence of tremor. Robotic aid combined with filtering techniques that suppress tremor frequency bands increases performance; however, if knowledge of the operator's goals is available, virtual fixtures have been shown to greatly improve micromanipulator precision. In this paper, we derive a control law for position-based virtual fixtures within the framework of an active handheld micromanipulator, where the fixtures are generated in real-time from microscope video. Additionally, we develop motion scaling behavior centered on virtual fixtures as a simple and direct extension to our formulation. We demonstrate that hard and soft (motion-scaled) virtual fixtures outperform state-of-the-art tremor cancellation performance on a set of artificial but medically relevant tasks: holding, move-and-hold, curve tracing, and volume restriction. Brian C. Becker, Robert A. MacLachlan, Gregory D. Hager, Cameron N. Riviere |
ICRA | 1 |
| 2011 | State estimation and feedforward tremor suppression for a handheld micromanipulator with a Kalman filterabstractActive compensation of physiological tremor for handheld micromanipulators depends on fast control and actuation responses. Because of real-world latencies, real-time compensation is usually not completely effective at eliminating unwanted hand motion. By modeling tremor, more effective cancellation is possible by anticipating future hand motion. We propose a feedforward control strategy that utilizes tremor velocity from a state-estimating Kalman filter. We demonstrate that estimating hand motion in a feedforward controller overcomes real-world latencies in micromanipulator actuation. In hold-still tasks with a fully handheld micromanipulator, the proposed feedforward approach improves tremor rejection by over 50%. Brian C. Becker, Robert A. MacLachlan, Cameron N. Riviere |
IROS | 1 |
| 2009 | Active guidance of a handheld micromanipulator using visual servoingabstractIn microsurgery, a surgeon often deals with anatomical structures of sizes that are close to the limit of the human hand accuracy. Robotic assistants can help to push beyond the current state of practice by integrating imaging and robot-assisted tools. This paper demonstrates control of a handheld tremor reduction micromanipulator with visual servo techniques, aiding the operator by providing three behaviors: snap-to, motion-scaling, and standoff-regulation. A stereo camera setup viewing the workspace under high magnification tracks the tip of the micromanipulator and the desired target object being manipulated. Individual behaviors activate in task-specific situations when the micromanipulator tip is in the vicinity of the target. We show that the snap-to behavior can reach and maintain a position at a target with an accuracy of 17.5 ± 0.4μm Root Mean Squared Error (RMSE) distance between the tip and target. Scaling the operator's motions and preventing unwanted contact with non-target objects also provides a larger margin of safety. Brian C. Becker, Sandrine Voros, Robert A. MacLachlan, Gregory D. Hager, Cameron N. Riviere |
ICRA | 1 |