Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Stéphane Lavallée

dblp:62/5490 · DBLP profile ↗
← Back
19ranked-venue papers
2as first author
0since 2021 · last 2005
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 12Graphics, computer vision, multimedia, augmented reality and games · 11Artificial intelligence and machine learning · 7 · 2 first-authorSystems, architecture and hardware · 3 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
6 papers
3D vision · 44% Robot manipulation · 34% Motion planning and robot control · 16%
Interdisciplinary, comprehensive, and emerging computing
4 papers
Medical and health informatics · 100%
Computer graphics and multimedia
2 papers
Geometric modeling and processing · 100%

Topics — the 15 heaviest of 17, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation
robot design
0.112005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Medical and health informatics › surgical robotics
orthopedic surgical robot
0.112005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Medical and health informatics
surgical robotics
0.112005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Robotics › Motion planning and robot control
robot control
0.022005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Image guided operating robot: a clinical application in stereotactic neurosurgery · ICRA 1992
Computer vision › 3D vision › geometric estimation › registration
non-rigid registration
0.011996
Matching 3-D anatomical surfaces with non-rigid deformations using octree-splines · Int. J. Comput. Vis. 1996
Computer vision › 3D vision
shape matching
0.011996
Matching 3-D anatomical surfaces with non-rigid deformations using octree-splines · Int. J. Comput. Vis. 1996
Geometric modeling and processing › registration
2d/3d registration
0.011995
Recovering the Position and Orientation of Free-Form Objects from Image Contours Using 3D Distance Maps · IEEE Trans. Pattern Anal. Mach. Intell. 1995
Medical and health informatics
computer-assisted surgery
0.021995
Image guided operating robot: a clinical application in stereotactic neurosurgery · ICRA 1992
Recovering the Position and Orientation of Free-Form Objects from Image Contours Using 3D Distance Maps · IEEE Trans. Pattern Anal. Mach. Intell. 1995
Computer vision › 3D vision
3d reconstruction
0.011992
From accurate range imaging sensor calibration to accurate model-based 3D object localization · CVPR 1992
Computer vision › 3D vision
camera calibration
0.011992
From accurate range imaging sensor calibration to accurate model-based 3D object localization · CVPR 1992
Computer vision › 3D vision
object pose estimation
0.011992
Using Force Fields Derived from 3D Distance Maps for Inferring the Attitude of a 3D Rigid Object · ECCV 1992
Computer vision › 3D vision › 3d reconstruction
range image registration
0.011992
From accurate range imaging sensor calibration to accurate model-based 3D object localization · CVPR 1992
Robotics › Robot navigation and mapping
sensor calibration
0.011992
Accurate calibration of cameras and range imaging sensor: the NPBS method · ICRA 1992
Computer vision › 3D vision › range sensing › depth sensing
range image
0.011992
Accurate calibration of cameras and range imaging sensor: the NPBS method · ICRA 1992
Medical and health informatics
medical imaging
0.011992
Image guided operating robot: a clinical application in stereotactic neurosurgery · ICRA 1992

Methods — techniques the papers use, named apart from their topics

mechanical braking system · 0.1gear transmission · 0.1octree-splines · 0.0levenberg-marquardt · 0.0best-first search · 0.0octree-spline · 0.0linear guide · 0.0force fields · 0.03d distance maps · 0.0octree spline · 0.0six-axis robot · 0.0nonlinear least squares · 0.0n-planes b-spline · 0.0b-spline model · 0.0b-spline approximation · 0.0
YearPublicationVenuePosition
2005 Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery
abstract
The objective of this work was to design a compact, accurate, safe, and ease-to-use surgical robot for total knee arthroplasty. The goal of the bone-mounted robot, named Praxiteles, is to precisely position a surgical bone-cutting guide in the appropriate planes surrounding the knee, so that the surgeon can perform the cuts manually using the guide. The robot architecture is comprised of 2 motorized degrees of freedom (DOF) whose axes of rotation are arranged in parallel, and are precisely aligned to the implant cutting planes with a 2 DOF serial adjustment mechanism. An initial prototype was first developed and tested on saw bones and cadavers, and construction of a new, refined version is now well underway. A backdrivable system, with high-stiffness, high-precision static positioning capabilities and safe low-force dynamic movement is achieved using a quick-release, spring-loaded mechanical braking system integrated in a gear transmission unit at the level of the motor outputs. This paper discusses the technical challenges encountered during the development, design, and construction of the system.
Christopher Plaskos, Philippe Cinquin, Antony J. Hodgson, Stéphane Lavallée
ICRA4
2002 Integrated Approach for Matching Statistical Shape Models with Intra-operative 2D and 3D Data
Markus Fleute, Stéphane Lavallée, Laurent Desbat
MICCAI (2)2
2001 TER: A System for Robotic Tele-echography
Adriana Vilchis Gonzales, Philippe Cinquin, Jocelyne Troccaz, Agnès Guerraz, Bernard Hennion, Franck Pellissier, Pierre Thorel, Fabien Courreges, Alain Gourdon, Gérard Poisson, Pierre Vieyres, Pierre Caron, Olivier Mérigeaux, Loïc Urbain, Cédric Daimo, Stéphane Lavallée, Philippe Arbeille, Marc Althuser, Jean-Marc Ayoubi, Bertrand Tondu, Serge Ippolito
MICCAI16
1999 The Mesh-matching Algorithm: A New Automatic 3D Mesh Generator for Finite Element Analysis
Béatrice Couteau, Yohan Payan, Stéphane Lavallée, Marie Christine Ho Ba Tho
MICCAI3
1999 Nonrigid 3-D/2-D Registration of Images Using Statistical Models
Markus Fleute, Stéphane Lavallée
MICCAI2
1999 Automated Registration of Ultrasound with CT Images: Application to Computer Assisted Prostate Radiotherapy and Orthopedics
Gelu Ionescu, Stéphane Lavallée, Jacques Demongeot
MICCAI2
1999 Incorporating a statistically based shape model into a system for computer-assisted anterior cruciate ligament surgery
Markus Fleute, Stéphane Lavallée, Rémi Julliard
Medical Image Anal.2
1999 Medical image analysis : Foreword
Russel Taylor, Stéphane Lavallée
Medical Image Anal.2
1999 CRIGOS: a compact robot for image-guided orthopedic surgery
abstract
The CRIGOS (compact robot for image-guided orthopedic surgery) project was set up for the development of a compact surgical robot system for image-guided orthopedic surgery based on user requirements. The modular system comprises a compact parallel robot and a software system for planning of the surgical interventions and for supervision of the robotic device. Because it is not sufficient to consider only technical aspects in order to improve in clinical routine the therapeutic outcome of conventional interventions, a user-centered and task-oriented design process has been developed which also takes human factors into account. The design process for the CRIGOS system was started from requirement analysis of various orthopedic interventions using information gathered from literature, questionnaires, and workshops with domain experts. This resulted in identification of conventional interventions for which the robotic system would improve the medical and procedural quality. A system design concept has been elaborated which includes definitions of components, functionalities, and interfaces. Approaches to the acquisition of calibrated X-rays will be presented in the paper together with design and evaluation of a first human-computer interface. Finally, the first labtype parallel robot based on low-cost standard components is presented together with the first evaluation results concerning positioning accuracy.
G. Brandt, Andreas Zimolong, Lionel Carrat, Philippe Merloz, H.-W. Staudte, Stéphane Lavallée, Klaus Radermacher 0001, Günther Rau
IEEE Trans. Inf. Technol. Biomed.6
1998 Treatment of Pelvic Ring Fractures: Percutaneous Computer Assisted Iliosacral Screwing
Lionel Carrat, Jérôme Tonetti, Stéphane Lavallée, Philippe Merloz, Laurence Pittet, Jean-Paul Chirossel
MICCAI3
1998 Experimental Protocol for Accuracy Evaluation of 6-d Localizers for Computer-Integrated Surgery: Application to Four Optical Localizers
Fabrice Chassat, Stéphane Lavallée
MICCAI2
1998 Building a Complete Surface Model from Sparse Data Using Statistical Shape Models: Application to Computer Assisted Knee Surgery System
Markus Fleute, Stéphane Lavallée
MICCAI2
1998 Computer Assisted Orthognathic Surgery
Benoit Mollard, Stéphane Lavallée, Georges Bettega
MICCAI2
1996 Matching 3-D anatomical surfaces with non-rigid deformations using octree-splines
Richard Szeliski, Stéphane Lavallée
Int. J. Comput. Vis.2
1995 Recovering the Position and Orientation of Free-Form Objects from Image Contours Using 3D Distance Maps
abstract
The accurate matching of 3D anatomical surfaces with sensory data such as 2D X-ray projections is a basic problem in computer and robot assisted surgery, In model-based vision, this problem can be formulated as the estimation of the spatial pose (position and orientation) of a 3D smooth object from 2D video images. The authors present a new method for determining the rigid body transformation that describes this match. The authors' method performs a least squares minimization of the energy necessary to bring the set of the camera-contour projection lines tangent to the surface. To correctly deal with projection lines that penetrate the surface, the authors consider the minimum signed distance to the surface along each line (i.e., distances inside the object are negative). To quickly and accurately compute distances to the surface, the authors introduce a precomputed distance map represented using an octree spline whose resolution increases near the surface. This octree structure allows the authors to quickly find the minimum distance along each line using best-first search. Experimental results for 3D surface to 2D projection matching are presented for both simulated and real data. The combination of the authors' problem formulation in 3D, their computation of line to surface distances with the octree-spline distance map, and their simple minimization technique based on the Levenberg-Marquardt algorithm results in a method that solves the 3D/2D matching problem for arbitrary smooth shapes accurately and quickly.>
Stéphane Lavallée, Richard Szeliski
IEEE Trans. Pattern Anal. Mach. Intell.1
1992 From accurate range imaging sensor calibration to accurate model-based 3D object localization
abstract
The registration of multiple 3D data sets obtained with a laser range finder is examined. A sensor calibration technique based on the conjunction of a mathematical camera model, the N-planes B-spline (NPBS), with an accurate mechanical calibration setup, is proposed. An algorithm for recovering the rigid transformation (rotation and translation) between the two sets of 3D coordinates obtained by the calibrated imaging range sensor is developed. Its input is sets of points lying on the surface of the object. This input is converted into an octree-spline that allows point-to-surface distances to be computed quickly. A robust nonlinear least-squares minimization technique then finds the optimal pose by minimizing the sum of square distances between the two sets of 3D coordinates. The algorithm has been applied to matching human faces with highly accurate results.>
Guillaume Champleboux, Stéphane Lavallée, Richard Szeliski, Lionel Brunie
CVPR2
1992 Using Force Fields Derived from 3D Distance Maps for Inferring the Attitude of a 3D Rigid Object
Lionel Brunie, Stéphane Lavallée, Richard Szeliski
ECCV2
1992 Accurate calibration of cameras and range imaging sensor: the NPBS method
abstract
A method is presented for modeling and calibration of sensors, to reach an accuracy similar in magnitude to the resolution of the sensors. The authors focus on camera and range image calibration. They show the limitations of existing methods, and present an approach and camera calibration using mathematical B-Spline functions. This method is abbreviated as NPBS (N-Planes B-Spline). It is an extension of the two-planes method, but relies on pure mathematical modeling based on spline approximation theory. The mathematical modeling is combined with a calibration device that enables accurate data acquisition to calibrate a camera and a light plane independently. Experimental results are presented showing accuracy on the determination of a scattered plane.>
Guillaume Champleboux, Stéphane Lavallée, Pascal Sautot, Philippe Cinquin
ICRA2
1992 Image guided operating robot: a clinical application in stereotactic neurosurgery
abstract
Describes a system based on the combined use of medical imaging and robot positioning used in stereotactic neurosurgery. The types of interventions performed with the help of this system require a high precision (less than 1 millimeter) of positioning with respect to the patients brain with no direct visibility of the target; they are executed through a hole in the skull of 2.3 millimeters. A typical example is the placement of a stimulating electrode in a particular nucleus of the thalamus for patients suffering from Parkinson's disease. These interventions rely on the intensive use of medical imaging to define the operative strategy. The target is defined with respect to the images. A six-axis robot whose end-effector is a linear guide automatically reaches a configuration generated such that if the surgical instrument (needle, electrode, etc.) is introduced in the guide, the surgeon reaches the target using a linear displacement of the instrument. This system is operational and is in routine clinical use.>
Stéphane Lavallée, Jocelyne Troccaz, L. Gaborit, Philippe Cinquin, Alim-Louis Benabid, Dominque Hoffmann
ICRA1