Ivana Isgum

dblp:62/5757 · DBLP profile ↗
← Back
33ranked-venue papers
3as first author
7since 2021 · last 2025
0000-0003-1869-5034ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 33 · 3 first-author · 7 since 2021Graphics, computer vision, multimedia, augmented reality and games · 5
YearPublicationVenuePosition
2025 World of Forms: Deformable geometric templates for one-shot surface meshing in coronary CT angiography
abstract
Deep learning-based medical image segmentation and surface mesh generation typically involve a sequential pipeline from image to segmentation to meshes, often requiring large training datasets while making limited use of prior geometric knowledge. This may lead to topological inconsistencies and suboptimal performance in low-data regimes. To address these challenges, we propose a data-efficient deep learning method for direct 3D anatomical object surface meshing using geometric priors. Our approach employs a multi-resolution graph neural network that operates on a prior geometric template which is deformed to fit object boundaries of interest. We show how different templates may be used for the different surface meshing targets, and introduce a novel masked autoencoder pretraining strategy for 3D spherical data. The proposed method outperforms nnUNet in a one-shot setting for segmentation of the pericardium, left ventricle (LV) cavity and the LV myocardium. Similarly, the method outperforms other lumen segmentation operating on multi-planar reformatted images. Results further indicate that mesh quality is on par with or improves upon marching cubes post-processing of voxel mask predictions, while remaining flexible in the choice of mesh triangulation prior, thus paving the way for more accurate and topologically consistent 3D medical object surface meshing.
Rudolf L. M. van Herten, Ioannis Lagogiannis, Jelmer M. Wolterink, Steffen Bruns, Eva R. Meulendijks, Damini Dey, Joris R. de Groot, José P. Henriques, Nils Planken, Simone Saitta, Ivana Isgum
Medical Image Anal.11
2025 Real-time placental vessel segmentation in fetoscopic laser surgery for Twin-to-Twin Transfusion Syndrome
abstract
Twin-to-Twin Transfusion Syndrome (TTTS) is a rare condition that affects about 15% of monochorionic pregnancies, in which identical twins share a single placenta. Fetoscopic laser photocoagulation (FLP) is the standard treatment for TTTS, which significantly improves the survival of fetuses. The aim of FLP is to identify abnormal connections between blood vessels and to laser ablate them in order to equalize blood supply to both fetuses. However, performing fetoscopic surgery is challenging due to limited visibility, a narrow field of view, and significant variability among patients and domains. In order to enhance the visualization of placental vessels during surgery, we propose TTTSNet, a network architecture designed for real-time and accurate placental vessel segmentation. Our network architecture incorporates a novel channel attention module and multi-scale feature fusion module to precisely segment tiny placental vessels. To address the challenges posed by FLP-specific fiberscope and amniotic sac-based artifacts, we employed novel data augmentation techniques. These techniques simulate various artifacts, including laser pointer, amniotic sac particles, and structural and optical fiber artifacts. By incorporating these simulated artifacts during training, our network architecture demonstrated robust generalizability. We trained TTTSNet on a publicly available dataset of 2060 video frames from 18 independent fetoscopic procedures and evaluated it on a multi-center external dataset of 24 in-vivo procedures with a total of 2348 video frames. Our method achieved significant performance improvements compared to state-of-the-art methods, with a mean Intersection over Union of 78.26% for all placental vessels and 73.35% for a subset of tiny placental vessels. Moreover, our method achieved 172 and 152 frames per second on an A100 GPU, and Clara AGX, respectively. This potentially opens the door to real-time application during surgical procedures. The code is publicly available at https://github.com/SanoScience/TTTSNet.
Szymon Plotka, Tomasz Szczepanski, Paula Szenejko, Przemyslaw Korzeniowski, Jesús Rodriguez Calvo, Asma Khalil, Alireza Shamshirsaz, Robert Brawura-Biskupski-Samaha, Ivana Isgum, Clara I. Sánchez, Arkadiusz Sitek
Medical Image Anal.9
2024 Robust Deformable Image Registration Using Cycle-Consistent Implicit Representations
abstract
Recent works in medical image registration have proposed the use of Implicit Neural Representations, demonstrating performance that rivals state-of-the-art learning-based methods. However, these implicit representations need to be optimized for each new image pair, which is a stochastic process that may fail to converge to a global minimum. To improve robustness, we propose a deformable registration method using pairs of cycle-consistent Implicit Neural Representations: each implicit representation is linked to a second implicit representation that estimates the opposite transformation, causing each network to act as a regularizer for its paired opposite. During inference, we generate multiple deformation estimates by numerically inverting the paired backward transformation and evaluating the consensus of the optimized pair. This consensus improves registration accuracy over using a single representation and results in a robust uncertainty metric that can be used for automatic quality control. We evaluate our method with a 4D lung CT dataset. The proposed cycle-consistent optimization method reduces the optimization failure rate from 2.4% to 0.0% compared to the current state-of-the-art. The proposed inference method improves landmark accuracy by 4.5% and the proposed uncertainty metric detects all instances where the registration method fails to converge to a correct solution. We verify the generalizability of these results to other data using a centerline propagation task in abdominal 4D MRI, where our method achieves a 46% improvement in propagation consistency compared with single-INR registration and demonstrates a strong correlation between the proposed uncertainty metric and registration accuracy.
Louis D. van Harten, Jaap Stoker, Ivana Isgum
IEEE Trans. Medical Imaging3
2024 Automatic Coronary Artery Plaque Quantification and CAD-RADS Prediction Using Mesh Priors
abstract
Coronary artery disease (CAD) remains the leading cause of death worldwide. Patients with suspected CAD undergo coronary CT angiography (CCTA) to evaluate the risk of cardiovascular events and determine the treatment. Clinical analysis of coronary arteries in CCTA comprises the identification of atherosclerotic plaque, as well as the grading of any coronary artery stenosis typically obtained through the CAD-Reporting and Data System (CAD-RADS). This requires analysis of the coronary lumen and plaque. While voxel-wise segmentation is a commonly used approach in various segmentation tasks, it does not guarantee topologically plausible shapes. To address this, in this work, we propose to directly infer surface meshes for coronary artery lumen and plaque based on a centerline prior and use it in the downstream task of CAD-RADS scoring. The method is developed and evaluated using a total of 2407 CCTA scans. Our method achieved lesion-wise volume intraclass correlation coefficients of 0.98, 0.79, and 0.85 for calcified, non-calcified, and total plaque volume respectively. Patient-level CAD-RADS categorization was evaluated on a representative hold-out test set of 300 scans, for which the achieved linearly weighted kappa ( κ ) was 0.75. CAD-RADS categorization on the set of 658 scans from another hospital and scanner led to a κ of 0.71. The results demonstrate that direct inference of coronary artery meshes for lumen and plaque is feasible, and allows for the automated prediction of routinely performed CAD-RADS categorization.
Rudolf L. M. van Herten, Nils Hampe, Richard A. P. Takx, Klaas Jan Franssen, Dominika Suchá, José P. Henriques, Tim Leiner, Nils Planken, Ivana Isgum
IEEE Trans. Medical Imaging10
2023 Spatio-temporal physics-informed learning: A novel approach to CT perfusion analysis in acute ischemic stroke
abstract
CT perfusion imaging is important in the imaging workup of acute ischemic stroke for evaluating affected cerebral tissue. CT perfusion analysis software produces cerebral perfusion maps from commonly noisy spatio-temporal CT perfusion data. High levels of noise can influence the results of CT perfusion analysis, necessitating software tuning. This work proposes a novel approach for CT perfusion analysis that uses physics-informed learning, an optimization framework that is robust to noise. In particular, we propose SPPINN: Spatio-temporal Perfusion Physics-Informed Neural Network and research spatio-temporal physics-informed learning. SPPINN learns implicit neural representations of contrast attenuation in CT perfusion scans using the spatio-temporal coordinates of the data and employs these representations to estimate a continuous representation of the cerebral perfusion parameters. We validate the approach on simulated data to quantify perfusion parameter estimation performance. Furthermore, we apply the method to in-house patient data and the public Ischemic Stroke Lesion Segmentation 2018 benchmark data to assess the correspondence between the perfusion maps and reference standard infarct core segmentations. Our method achieves accurate perfusion parameter estimates even with high noise levels and differentiates healthy tissue from infarcted tissue. Moreover, SPPINN perfusion maps accurately correspond with reference standard infarct core segmentations. Hence, we show that using spatio-temporal physics-informed learning for cerebral perfusion estimation is accurate, even in noisy CT perfusion data. The code for this work is available at https://github.com/lucasdevries/SPPINN.
Lucas de Vries, Rudolf L. M. van Herten, Jan W. Hoving, Ivana Isgum, Bart J. Emmer, Charles B. L. M. Majoie, Henk A. Marquering, Efstratios Gavves
Medical Image Anal.4
2022 Untangling and segmenting the small intestine in 3D cine-MRI using deep learning
abstract
Cine-MRI of the abdomen is a non-invasive imaging technique allowing assessment of small intestinal motility. This is valuable for the evaluation of gastrointestinal disorders. While 2D cine-MRI is increasingly used for this purpose in both clinical practice and in research settings, the potential of 3D cine-MRI has been largely underexplored. In the absence of image analysis tools enabling investigation of the intestines as 3D structures, the assessment of motility in 3D cine-images is generally limited to the evaluation of movement in separate 2D slices. Furthermore, while a segmentation map of the small intestine would be required for a number of automatic analysis tasks, deep learning based segmentation of the small intestine generally performs poorly due to the large variety in shapes, sizes and locations in the abdomen among different patients. Using a data set of 3D cine-MRI scans from 14 healthy volunteers, we developed a multi-task method that automatically tracks individual segments of the small intestine in a time-point from 3D cine-MRI scans, using a stochastic tracker built on top of a CNN-based orientation classifier. The method additionally performs segmentation, conditioned on the locations of intestinal centerlines. We demonstrate the benefit of our stochastic tracking strategy and we show that our proposed segmentation method performs significantly better than an identical network without centerline conditioning. Furthermore, we assess the robustness of the method through evaluation on a set of patients with severe bowel disease. In terms of centerline tracking, our method achieves a recall of 0.74±0.07, a precision of 0.80±0.06 and an F1 score of 0.77±0.05 in the set of healthy volunteers. In the set of patients, it achieves a recall of 0.76±0.12, a precision of 0.86±0.11 and an F1 score of 0.80±0.08. Segmentation achieves a Dice coefficient of 0.88±0.03 in the set of healthy volunteers and 0.79±0.09 in the set of patients. By extracting a structural representation of the small intestine, the presented method provides a major first step towards automatic detailed quantitative assessment of small intestinal motility in abdominal 3D cine-MRI.
Louis D. van Harten, Catharina S. de Jonge, Kim J. Beek, Jaap Stoker, Ivana Isgum
Medical Image Anal.5
2022 Autoencoding low-resolution MRI for semantically smooth interpolation of anisotropic MRI
abstract
High-resolution medical images are beneficial for analysis but their acquisition may not always be feasible. Alternatively, high-resolution images can be created from low-resolution acquisitions using conventional upsampling methods, but such methods cannot exploit high-level contextual information contained in the images. Recently, better performing deep-learning based super-resolution methods have been introduced. However, these methods are limited by their supervised character, i.e. they require high-resolution examples for training. Instead, we propose an unsupervised deep learning semantic interpolation approach that synthesizes new intermediate slices from encoded low-resolution examples. To achieve semantically smooth interpolation in through-plane direction, the method exploits the latent space generated by autoencoders. To generate new intermediate slices, latent space encodings of two spatially adjacent slices are combined using their convex combination. Subsequently, the combined encoding is decoded to an intermediate slice. To constrain the model, a notion of semantic similarity is defined for a given dataset. For this, a new loss is introduced that exploits the spatial relationship between slices of the same volume. During training, an existing in-between slice is generated using a convex combination of its neighboring slice encodings. The method was trained and evaluated using publicly available cardiac cine, neonatal brain and adult brain MRI scans. In all evaluations, the new method produces significantly better results in terms of Structural Similarity Index Measure and Peak Signal-to-Noise Ratio (p<0.001 using one-sided Wilcoxon signed-rank test) than a cubic B-spline interpolation approach. Given the unsupervised nature of the method, high-resolution training data is not required and hence, the method can be readily applied in clinical settings.
Jörg Sander 0003, Bob D. de Vos, Ivana Isgum
Medical Image Anal.3
2020 Deep Learning-Based Regression and Classification for Automatic Landmark Localization in Medical Images
abstract
In this study, we propose a fast and accurate method to automatically localize anatomical landmarks in medical images. We employ a global-to-local localization approach using fully convolutional neural networks (FCNNs). First, a global FCNN localizes multiple landmarks through the analysis of image patches, performing regression and classification simultaneously. In regression, displacement vectors pointing from the center of image patches towards landmark locations are determined. In classification, presence of landmarks of interest in the patch is established. Global landmark locations are obtained by averaging the predicted displacement vectors, where the contribution of each displacement vector is weighted by the posterior classification probability of the patch that it is pointing from. Subsequently, for each landmark localized with global localization, local analysis is performed. Specialized FCNNs refine the global landmark locations by analyzing local sub-images in a similar manner, i.e. by performing regression and classification simultaneously and combining the results. Evaluation was performed through localization of 8 anatomical landmarks in CCTA scans, 2 landmarks in olfactory MR scans, and 19 landmarks in cephalometric X-rays. We demonstrate that the method performs similarly to a second observer and is able to localize landmarks in a diverse set of medical images, differing in image modality, image dimensionality, and anatomical coverage.
Julia M. H. Noothout, Bob D. de Vos, Jelmer M. Wolterink, Elbrich M. Postma, Paul A. M. Smeets, Richard A. P. Takx, Tim Leiner, Max A. Viergever, Ivana Isgum
IEEE Trans. Medical Imaging9
2020 Deep Learning Analysis of Coronary Arteries in Cardiac CT Angiography for Detection of Patients Requiring Invasive Coronary Angiography
abstract
In patients with obstructive coronary artery disease, the functional significance of a coronary artery stenosis needs to be determined to guide treatment. This is typically established through fractional flow reserve (FFR) measurement, performed during invasive coronary angiography (ICA). We present a method for automatic and non-invasive detection of patients requiring ICA, employing deep unsupervised analysis of complete coronary arteries in cardiac CT angiography (CCTA) images. We retrospectively collected CCTA scans of 187 patients, 137 of them underwent invasive FFR measurement in 192 different coronary arteries. These FFR measurements served as a reference standard for the functional significance of the coronary stenosis. The centerlines of the coronary arteries were extracted and used to reconstruct straightened multi-planar reformatted (MPR) volumes. To automatically identify arteries with functionally significant stenosis that require ICA, each MPR volume was encoded into a fixed number of encodings using two disjoint 3D and 1D convolutional autoencoders performing spatial and sequential encodings, respectively. Thereafter, these encodings were employed to classify arteries using a support vector machine classifier. The detection of coronary arteries requiring invasive evaluation, evaluated using repeated cross-validation experiments, resulted in an area under the receiver operating characteristic curve of 0.81 ± 0.02 on the artery-level, and 0.87 ± 0.02 on the patient-level. The results demonstrate the feasibility of automatic non-invasive detection of patients that require ICA and possibly subsequent coronary artery intervention. This could potentially reduce the number of patients that unnecessarily undergo ICA.
Majd Zreik, Robbert W. van Hamersvelt, Nadieh Khalili, Jelmer M. Wolterink, Michiel Voskuil, Max A. Viergever, Tim Leiner, Ivana Isgum
IEEE Trans. Medical Imaging8
2019 Adversarial Optimization for Joint Registration and Segmentation in Prostate CT Radiotherapy
Mohamed S. Elmahdy, Jelmer M. Wolterink, Hessam Sokooti, Ivana Isgum, Marius Staring
MICCAI (6)4
2019 Generative Adversarial Network for Segmentation of Motion Affected Neonatal Brain MRI
Nadieh Khalili, Elise Turk, Majd Zreik, Max A. Viergever, Manon J. N. L. Benders, Ivana Isgum
MICCAI (3)6
2019 Convolutional Neural Network-Based Regression for Quantification of Brain Characteristics Using MRI
João Fernandes 0004, Victor Alves, Nadieh Khalili, Manon J. N. L. Benders, Ivana Isgum, Josien P. W. Pluim, Pim Moeskops
WorldCIST (2)5
2019 Iterative fully convolutional neural networks for automatic vertebra segmentation and identification
Nikolas Leßmann, Bram van Ginneken, Pim A. de Jong, Ivana Isgum
Medical Image Anal.4
2019 A deep learning framework for unsupervised affine and deformable image registration
Bob D. de Vos, Floris F. Berendsen, Max A. Viergever, Hessam Sokooti, Marius Staring, Ivana Isgum
Medical Image Anal.6
2019 Coronary artery centerline extraction in cardiac CT angiography using a CNN-based orientation classifier
Jelmer M. Wolterink, Robbert W. van Hamersvelt, Max A. Viergever, Tim Leiner, Ivana Isgum
Medical Image Anal.5
2019 Direct Automatic Coronary Calcium Scoring in Cardiac and Chest CT
abstract
Cardiovascular disease (CVD) is the global leading cause of death. A strong risk factor for CVD events is the amount of coronary artery calcium (CAC). To meet the demands of the increasing interest in quantification of CAC, i.e., coronary calcium scoring, especially as an unrequested finding for screening and research, automatic methods have been proposed. The current automatic calcium scoring methods are relatively computationally expensive and only provide scores for one type of CT. To address this, we propose a computationally efficient method that employs two convolutional neural networks: the first performs registration to align the fields of view of input CTs and the second performs direct regression of the calcium score, thereby circumventing time-consuming intermediate CAC segmentation. Optional decision feedback provides insight into the regions that are contributed to the calcium score. Experiments were performed using 903 cardiac CT and 1687 chest CT scans. The method predicted calcium scores in less than 0.3 s. The intra-class correlation coefficient between predicted and manual calcium scores was 0.98 for both cardiac and chest CT. The method showed almost perfect agreement between automatic and manual CVD risk categorization in both the datasets, with a linearly weighted Cohen's kappa of 0.95 in cardiac CT and 0.93 in chest CT. Performance is similar to that of the state-of-the-art methods, but the proposed method is hundreds of times faster. By providing visual feedback, insight is given in the decision process, making it readily implementable in clinical and research settings.
Bob D. de Vos, Jelmer M. Wolterink, Tim Leiner, Pim A. de Jong, Nikolas Leßmann, Ivana Isgum
IEEE Trans. Medical Imaging6
2019 A Recurrent CNN for Automatic Detection and Classification of Coronary Artery Plaque and Stenosis in Coronary CT Angiography
abstract
Various types of atherosclerotic plaque and varying grades of stenosis could lead to different management of patients with a coronary artery disease. Therefore, it is crucial to detect and classify the type of coronary artery plaque, as well as to detect and determine the degree of coronary artery stenosis. This paper includes retrospectively collected clinically obtained coronary CT angiography (CCTA) scans of 163 patients. In these, the centerlines of the coronary arteries were extracted and used to reconstruct multi-planar reformatted (MPR) images for the coronary arteries. To define the reference standard, the presence and the type of plaque in the coronary arteries (no plaque, non-calcified, mixed, calcified), as well as the presence and the anatomical significance of coronary stenosis (no stenosis, non-significant, i.e., <50% luminal narrowing, and significant, i.e., ≥50% luminal narrowing) were manually annotated in the MPR images by identifying the start- and end-points of the segment of the artery affected by the plaque. To perform an automatic analysis, a multi-task recurrent convolutional neural network is applied on coronary artery MPR images. First, a 3D convolutional neural network is utilized to extract features along the coronary artery. Subsequently, the extracted features are aggregated by a recurrent neural network that performs two simultaneous multi-class classification tasks. In the first task, the network detects and characterizes the type of the coronary artery plaque. In the second task, the network detects and determines the anatomical significance of the coronary artery stenosis. The network was trained and tested using the CCTA images of 98 and 65 patients, respectively. For detection and characterization of coronary plaque, the method was achieved an accuracy of 0.77. For detection of stenosis and determination of its anatomical significance, the method was achieved an accuracy of 0.80. The results demonstrate that automatic detection and classification of coronary artery plaque and stenosis are feasible. This may enable automated triage of patients to those without coronary plaque and those with coronary plaque and stenosis in need for further cardiovascular workup.
Majd Zreik, Robbert W. van Hamersvelt, Jelmer M. Wolterink, Tim Leiner, Max A. Viergever, Ivana Isgum
IEEE Trans. Medical Imaging6
2018 Deep learning analysis of the myocardium in coronary CT angiography for identification of patients with functionally significant coronary artery stenosis
Majd Zreik, Nikolas Leßmann, Robbert W. van Hamersvelt, Jelmer M. Wolterink, Michiel Voskuil, Max A. Viergever, Tim Leiner, Ivana Isgum
Medical Image Anal.8
2018 Deep Learning Techniques for Automatic MRI Cardiac Multi-Structures Segmentation and Diagnosis: Is the Problem Solved?
abstract
Delineation of the left ventricular cavity, myocardium, and right ventricle from cardiac magnetic resonance images (multi-slice 2-D cine MRI) is a common clinical task to establish diagnosis. The automation of the corresponding tasks has thus been the subject of intense research over the past decades. In this paper, we introduce the "Automatic Cardiac Diagnosis Challenge" dataset (ACDC), the largest publicly available and fully annotated dataset for the purpose of cardiac MRI (CMR) assessment. The dataset contains data from 150 multi-equipments CMRI recordings with reference measurements and classification from two medical experts. The overarching objective of this paper is to measure how far state-of-the-art deep learning methods can go at assessing CMRI, i.e., segmenting the myocardium and the two ventricles as well as classifying pathologies. In the wake of the 2017 MICCAI-ACDC challenge, we report results from deep learning methods provided by nine research groups for the segmentation task and four groups for the classification task. Results show that the best methods faithfully reproduce the expert analysis, leading to a mean value of 0.97 correlation score for the automatic extraction of clinical indices and an accuracy of 0.96 for automatic diagnosis. These results clearly open the door to highly accurate and fully automatic analysis of cardiac CMRI. We also identify scenarios for which deep learning methods are still failing. Both the dataset and detailed results are publicly available online, while the platform will remain open for new submissions.
Olivier Bernard 0001, Alain Lalande, Clément Zotti, Frederic Cervenansky, Xin Yang 0009, Pheng-Ann Heng, Irem Cetin, Karim Lekadir, Oscar Camara 0001, Miguel Ángel González Ballester, Gerard Sanroma, Sandy Napel, Steffen E. Petersen, Georgios Tziritas, Ilias Grinias, Mahendra Khened, Alex Varghese, Ganapathy Krishnamurthi, Marc-Michel Rohé, Xavier Pennec, Maxime Sermesant, Fabian Isensee, Paul F. Jaeger, Klaus H. Maier-Hein, Peter M. Full, Ivo Wolf, Sandy Engelhardt, Christian F. Baumgartner, Lisa M. Koch, Jelmer M. Wolterink, Ivana Isgum, Yeonggul Jang, Yoonmi Hong, Jay Patravali, Shubham Jain 0006, Olivier Humbert, Pierre-Marc Jodoin
IEEE Trans. Medical Imaging31
2018 Automatic Calcium Scoring in Low-Dose Chest CT Using Deep Neural Networks With Dilated Convolutions
abstract
Heavy smokers undergoing screening with low-dose chest CT are affected by cardiovascular disease as much as by lung cancer. Low-dose chest CT scans acquired in screening enable quantification of atherosclerotic calcifications and thus enable identification of subjects at increased cardiovascular risk. This paper presents a method for automatic detection of coronary artery, thoracic aorta, and cardiac valve calcifications in low-dose chest CT using two consecutive convolutional neural networks. The first network identifies and labels potential calcifications according to their anatomical location and the second network identifies true calcifications among the detected candidates. This method was trained and evaluated on a set of 1744 CT scans from the National Lung Screening Trial. To determine whether any reconstruction or only images reconstructed with soft tissue filters can be used for calcification detection, we evaluated the method on soft and medium/sharp filter reconstructions separately. On soft filter reconstructions, the method achieved F1scores of 0.89, 0.89, 0.67, and 0.55 for coronary artery, thoracic aorta, aortic valve, and mitral valve calcifications, respectively. On sharp filter reconstructions, the F1scores were 0.84, 0.81, 0.64, and 0.66, respectively. Linearly weighted kappa coefficients for risk category assignment based on per subject coronary artery calcium were 0.91 and 0.90 for soft and sharp filter reconstructions, respectively. These results demonstrate that the presented method enables reliable automatic cardiovascular risk assessment in all low-dose chest CT scans acquired for lung cancer screening.
Nikolas Leßmann, Bram van Ginneken, Majd Zreik, Pim A. de Jong, Bob D. de Vos, Max A. Viergever, Ivana Isgum
IEEE Trans. Medical Imaging7
2017 Nonrigid Image Registration Using Multi-scale 3D Convolutional Neural Networks
Hessam Sokooti, Bob D. de Vos, Floris F. Berendsen, Boudewijn P. F. Lelieveldt, Ivana Isgum, Marius Staring
MICCAI (1)5
2017 ConvNet-Based Localization of Anatomical Structures in 3-D Medical Images
abstract
Localization of anatomical structures is a prerequisite for many tasks in a medical image analysis. We propose a method for automatic localization of one or more anatomical structures in 3-D medical images through detection of their presence in 2-D image slices using a convolutional neural network (ConvNet). A single ConvNet is trained to detect the presence of the anatomical structure of interest in axial, coronal, and sagittal slices extracted from a 3-D image. To allow the ConvNet to analyze slices of different sizes, spatial pyramid pooling is applied. After detection, 3-D bounding boxes are created by combining the output of the ConvNet in all slices. In the experiments, 200 chest CT, 100 cardiac CT angiography (CTA), and 100 abdomen CT scans were used. The heart, ascending aorta, aortic arch, and descending aorta were localized in chest CT scans, the left cardiac ventricle in cardiac CTA scans, and the liver in abdomen CT scans. Localization was evaluated using the distances between automatically and manually defined reference bounding box centroids and walls. The best results were achieved in the localization of structures with clearly defined boundaries (e.g., aortic arch) and the worst when the structure boundary was not clearly visible (e.g., liver). The method was more robust and accurate in localization multiple structures.
Bob D. de Vos, Jelmer M. Wolterink, Pim A. de Jong, Tim Leiner, Max A. Viergever, Ivana Isgum
IEEE Trans. Medical Imaging6
2017 Generative Adversarial Networks for Noise Reduction in Low-Dose CT
abstract
Noise is inherent to low-dose CT acquisition. We propose to train a convolutional neural network (CNN) jointly with an adversarial CNN to estimate routine-dose CT images from low-dose CT images and hence reduce noise. A generator CNN was trained to transform low-dose CT images into routine-dose CT images using voxelwise loss minimization. An adversarial discriminator CNN was simultaneously trained to distinguish the output of the generator from routine-dose CT images. The performance of this discriminator was used as an adversarial loss for the generator. Experiments were performed using CT images of an anthropomorphic phantom containing calcium inserts, as well as patient non-contrast-enhanced cardiac CT images. The phantom and patients were scanned at 20% and 100% routine clinical dose. Three training strategies were compared: the first used only voxelwise loss, the second combined voxelwise loss and adversarial loss, and the third used only adversarial loss. The results showed that training with only voxelwise loss resulted in the highest peak signal-to-noise ratio with respect to reference routine-dose images. However, CNNs trained with adversarial loss captured image statistics of routine-dose images better. Noise reduction improved quantification of low-density calcified inserts in phantom CT images and allowed coronary calcium scoring in low-dose patient CT images with high noise levels. Testing took less than 10 s per CT volume. CNN-based low-dose CT noise reduction in the image domain is feasible. Training with an adversarial network improves the CNNs ability to generate images with an appearance similar to that of reference routine-dose CT images.
Jelmer M. Wolterink, Tim Leiner, Max A. Viergever, Ivana Isgum
IEEE Trans. Medical Imaging4
2016 Deep Learning for Multi-task Medical Image Segmentation in Multiple Modalities
Pim Moeskops, Jelmer M. Wolterink, Bas H. M. van der Velden, Kenneth G. A. Gilhuijs, Tim Leiner, Max A. Viergever, Ivana Isgum
MICCAI (2)7
2016 Automatic coronary artery calcium scoring in cardiac CT angiography using paired convolutional neural networks
Jelmer M. Wolterink, Tim Leiner, Bob D. de Vos, Robbert W. van Hamersvelt, Max A. Viergever, Ivana Isgum
Medical Image Anal.6
2016 Automatic Segmentation of MR Brain Images With a Convolutional Neural Network
abstract
Automatic segmentation in MR brain images is important for quantitative analysis in large-scale studies with images acquired at all ages. This paper presents a method for the automatic segmentation of MR brain images into a number of tissue classes using a convolutional neural network. To ensure that the method obtains accurate segmentation details as well as spatial consistency, the network uses multiple patch sizes and multiple convolution kernel sizes to acquire multi-scale information about each voxel. The method is not dependent on explicit features, but learns to recognise the information that is important for the classification based on training data. The method requires a single anatomical MR image only. The segmentation method is applied to five different data sets: coronal T2-weighted images of preterm infants acquired at 30 weeks postmenstrual age (PMA) and 40 weeks PMA, axial T2-weighted images of preterm infants acquired at 40 weeks PMA, axial T1-weighted images of ageing adults acquired at an average age of 70 years, and T1-weighted images of young adults acquired at an average age of 23 years. The method obtained the following average Dice coefficients over all segmented tissue classes for each data set, respectively: 0.87, 0.82, 0.84, 0.86, and 0.91. The results demonstrate that the method obtains accurate segmentations in all five sets, and hence demonstrates its robustness to differences in age and acquisition protocol.
Pim Moeskops, Max A. Viergever, Adriënne Mendrik, Linda S. de Vries, Manon J. N. L. Benders, Ivana Isgum
IEEE Trans. Medical Imaging6
2015 Automatic Coronary Calcium Scoring in Cardiac CT Angiography Using Convolutional Neural Networks
Jelmer M. Wolterink, Tim Leiner, Max A. Viergever, Ivana Isgum
MICCAI (1)4
2015 Evaluation of automatic neonatal brain segmentation algorithms: The NeoBrainS12 challenge
Ivana Isgum, Manon J. N. L. Benders, Brian B. Avants, Manuel Jorge Cardoso, Serena J. Counsell, Elda Fischi Gomez, Laura Gui, Petra S. Huppi, Karina J. Kersbergen, Antonios Makropoulos, Andrew Melbourne, Pim Moeskops, Christian P. Mol, Maria Deprez, Daniel Rueckert, Julia A. Schnabel, Vedran Srhoj-Egekher, Jue Wu, Siying Wang 0004, Linda S. de Vries, Max A. Viergever
Medical Image Anal.1
2015 Automatic Coronary Calcium Scoring in Non-Contrast-Enhanced ECG-Triggered Cardiac CT With Ambiguity Detection
abstract
The amount of coronary artery calcification (CAC) is a strong and independent predictor of cardiovascular events. We present a system that automatically quantifies total patient and per coronary artery CAC in non-contrast-enhanced, ECG-triggered cardiac CT. The system identifies candidate calcifications that cannot be automatically labeled with high certainty and optionally presents these to an expert for review. Candidates were extracted by intensity-based thresholding and described by location features derived from estimated coronary artery positions, as well as size, shape and intensity features. Next, a two-class classifier distinguished between coronary calcifications and negatives or a multiclass classifier labeled CAC per coronary artery. Candidates that could not be labeled with high certainty were identified by entropy-based ambiguity detection and presented to an expert for review and possible relabeling. The system was evaluated with 530 test images. Using the two-class classifier, the intra-class correlation coefficient (ICC) between reference and automatically determined total patient CAC volume was 0.95. Using the multiclass classifier, the ICC between reference and automatically determined per artery CAC volume was 0.98 (LAD), 0.69 (LCX), and 0.95 (RCA). In 49% of CTs, no ambiguous candidates were identified, while review of the remaining CTs increased the ICC for total patient CAC volume to 1.00, and per artery CAC volume to 1.00 (LAD), 0.95 (LCX), and 0.99 (RCA). In conclusion, CAC can be automatically identified in non-contrast-enhanced ECG-triggered cardiac CT. Ambiguity detection with expert review may enable the application of automatic CAC scoring in the clinic with a performance comparable to that of a human expert.
Jelmer M. Wolterink, Tim Leiner, Richard A. P. Takx, Max A. Viergever, Ivana Isgum
IEEE Trans. Medical Imaging5
2012 Contextual computer-aided detection: Improving bright lesion detection in retinal images and coronary calcification identification in CT scans
Clara I. Sánchez, Meindert Niemeijer, Ivana Isgum, Alina V. Dumitrescu, Maria S. A. Suttorp-Schulten, Michael D. Abràmoff, Bram van Ginneken
Medical Image Anal.3
2012 Automatic Coronary Calcium Scoring in Low-Dose Chest Computed Tomography
abstract
The calcium burden as estimated from non-ECG-synchronized computed tomography (CT) exams acquired in screening of heavy smokers has been shown to be a strong predictor of cardiovascular events. We present a method for automatic coronary calcium scoring with low-dose, non-contrast-enhanced, non-ECG-synchronized chest CT. First, a probabilistic coronary calcium map was created using multi-atlas segmentation. This map assigned an a priori probability for the presence of coronary calcifications at every location in a scan. Subsequently, a statistical pattern recognition system was designed to identify coronary calcifications by texture, size, and spatial features; the spatial features were computed using the coronary calcium map. The detected calcifications were quantified in terms of volume and Agatston score. The best results were obtained by merging the results of three different supervised classification systems, namely direct classification with a nearest neighbor classifier, and two-stage classification with nearest neighbor and support vector machine classifiers.We used a total of 231 test scans containing 45,674 mm³ of coronary calcifications. The presented method detected on average 157/198 mm³ (sensitivity 79.2%) of coronary calcium volume with on average 4 mm false positive volume. Calcium scoring can be performed automatically in low-dose, non-contrast enhanced, non-ECG-synchronized chest CT in screening of heavy smokers to identify subjects who might benefit from preventive treatment.
Ivana Isgum, Mathias Prokop, Meindert Niemeijer, Max A. Viergever, Bram van Ginneken
IEEE Trans. Medical Imaging1
2010 Adaptive local multi-atlas segmentation: Application to the heart and the caudate nucleus
Eva M. van Rikxoort, Ivana Isgum, Yulia Arzhaeva, Marius Staring, Stefan Klein 0001, Max A. Viergever, Josien P. W. Pluim, Bram van Ginneken
Medical Image Anal.2
2009 Multi-Atlas-Based Segmentation With Local Decision Fusion - Application to Cardiac and Aortic Segmentation in CT Scans
abstract
A novel atlas-based segmentation approach based on the combination of multiple registrations is presented. Multiple atlases are registered to a target image. To obtain a segmentation of the target, labels of the atlas images are propagated to it. The propagated labels are combined by spatially varying decision fusion weights. These weights are derived from local assessment of the registration success. Furthermore, an atlas selection procedure is proposed that is equivalent to sequential forward selection from statistical pattern recognition theory. The proposed method is compared to three existing atlas-based segmentation approaches, namely 1) single atlas-based segmentation, 2) average-shape atlas-based segmentation, and 3) multi-atlas-based segmentation with averaging as decision fusion. These methods were tested on the segmentation of the heart and the aorta in computed tomography scans of the thorax. The results show that the proposed method outperforms other methods and yields results very close to those of an independent human observer. Moreover, the additional atlas selection step led to a faster segmentation at a comparable performance.
Ivana Isgum, Marius Staring, Annemarieke Rutten, Mathias Prokop, Max A. Viergever, Bram van Ginneken
IEEE Trans. Medical Imaging1