Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Ben Eldridge

dblp:63/3662 · DBLP profile ↗
← Back
3ranked-venue papers
0as first author
0since 2021 · last 2012
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Systems, architecture and hardware · 2Artificial intelligence and machine learning · 1Applied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Motion planning and robot control · 100%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%
Theoretical computer science
1 paper
Mathematical optimization · 100%

Topics — the 6 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Motion planning and robot control
robot control
0.021996
Constrained Cartesian motion control for teleoperated surgical robots · IEEE Trans. Robotics Autom. 1996
Control and Evaluation of a 7-Axis Surgical Robot for Laparoscopy · ICRA 1995
Medical and health informatics
surgical robotics
0.021996
Constrained Cartesian motion control for teleoperated surgical robots · IEEE Trans. Robotics Autom. 1996
Control and Evaluation of a 7-Axis Surgical Robot for Laparoscopy · ICRA 1995
Robotics › Motion planning and robot control › robot control › task-space robot control
cartesian space control
0.011996
Constrained Cartesian motion control for teleoperated surgical robots · IEEE Trans. Robotics Autom. 1996
Medical and health informatics
medical robotics
0.011996
Constrained Cartesian motion control for teleoperated surgical robots · IEEE Trans. Robotics Autom. 1996
Mathematical optimization › constrained optimization
constrained quadratic optimization
0.011996
Constrained Cartesian motion control for teleoperated surgical robots · IEEE Trans. Robotics Autom. 1996
Mathematical optimization › continuous optimization › nonlinear optimization
quadratic programming
0.011996
Constrained Cartesian motion control for teleoperated surgical robots · IEEE Trans. Robotics Autom. 1996

Methods — techniques the papers use, named apart from their topics

task frame formulation · 0.0constrained quadratic optimization · 0.0ergonomic evaluation · 0.0constrained cartesian controller · 0.0
YearPublicationVenuePosition
2012 Direct connection and testing of TSV and microbump devices using NanoPierce™ contactor for 3D-IC integration
abstract
Testing of Through Silicon Via (TSV) and Micro-Bump (MB) devices by physical connection through the TSVs presents unique challenges due to the very high density of the connections, and the potential impact of contact testing on subsequent assembly steps. In addition, the very high signal counts that are the main benefit of TSV connection schemes make conventional wafer probing, particularly for memory devices which demand very high parallelism at production wafer sort, largely impractical. We present a socket solution using FormFactor Nanopierce™ contactor for direct testing of TSV's and micro-bumps arrays which enables creation of known good TSV dies for high yield stacking and known good TSV stacks for shipment to system assemblers to achieve high yield assembly. Combining this socket solution with existing full wafer contact probe solutions enables a complete TSV test flow. In addition, standard TSV interface designs and patterns can enable standard sockets. The FormFactor NanoPierce™ contactor is highly scalable and easy to fabricate at very dense pitches down to 20μm. The contactor relies on many small contact points within one contact pad and good electrical connection can be achieved at low contact forces with minimal surface damage. We present test result on both Au pads and SnAg bumps performed at 40μm × 50μm pitch array wide I/O JEDEC pattern. The resistance per contact is ~3 Ohms with 25μm overtravel, and an estimated inductance of 0.1nH per contact. Test results show no detectable damage on the contactor, and small damage on 20μm SnAg bumps.
Onnik Yaglioglu, Ben Eldridge
VTS2
1996 Constrained Cartesian motion control for teleoperated surgical robots
abstract
This paper addresses the problem of optimal motion control for teleoperated surgical robots, which must maneuver in constrained workspaces, often through a narrow entry portal into the patient's body. The control problem is determining how best to use the available degrees of freedom of a surgical robot to accomplish a particular task, while respecting geometric constraints on the work volume, robot mechanism, and the specific task requirements. We present a method of formulating desired motions as sets of task goals in any number of coordinate frames (task frames) relevant to the task, optionally subject to additional linear constraints in each of the task frames. Mathematically, the kinematic control problem is posed as a constrained quadratic optimization problem and is shown to be computable in real time on a PC. We will present experimental results of the application of this control methodology to both kinematically deficient and kinematically redundant robots. Specifically, we will discuss the control issues within the context of a representative set of tasks in robot-assisted laparoscopy, which includes (but is not limited to) teleoperated navigation of a laparoscopic camera attached to a surgical robot. A system based on this control formalism has been used in preclinical in vivo studies at the Johns Hopkins University Medical Center and the early experience with the system will be summarized.
Janez Funda, Russell H. Taylor, Ben Eldridge, Stephen H. Gomory, Kreg Gruben
IEEE Trans. Robotics Autom.3
1995 Control and Evaluation of a 7-Axis Surgical Robot for Laparoscopy
abstract
This paper describes the control and ergonomic evaluation of a ceiling mounted (or support frame suspended) 7-axis surgical robot (HISAR) for laparoscopic camera navigation. A key feature of the robot is that it incorporates a passive wrist for natural compliance with the port of entry into the patient. The use of a previously reported constrained Cartesian controller is motivated and demonstrated, and the results of successfully applying this control methodology to the manipulator are presented. The significance of the control strategy is the ease with which control of passive axes, the fulcrum constraint, and the motion inversion effect created by the fulcrum are accommodated. We also report on the results of laboratory evaluations of the arm in terms of its work volume, ergonomic factors, ease of control, and overall design within the context of laparoscopic camera control.
Janez Funda, Kreg Gruben, Ben Eldridge, Stephen H. Gomory, Russell H. Taylor
ICRA3