Demo Data from EDBT 2026 / reviewers in the wild / expert
Jody Alessandro Saglia
dblp:63/7395
· DBLP profile ↗
5ranked-venue papers
2as first author
0since 2021 · last 2013
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 5 · 2 first-authorSystems, architecture and hardware · 5 · 2 first-author
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
4 papers |
Motion planning and robot control · 57% Robot manipulation · 24% Legged, aerial and field robots · 19% | |
| Human-computer interaction and pervasive computing
2 papers |
Human-robot interaction · 40% Accessibility and assistive technology · 34% Health and well-being technologies · 23% |
Topics — the 21 heaviest of 21, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Motion planning and robot control › robot control
impedance control |
0.2 | 1 | 2013 | Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device · ICRA 2013 |
Robotics › Motion planning and robot control
robot control |
0.2 | 1 | 2013 | Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device · ICRA 2013 |
Robotics › Motion planning and robot control › robot control › impedance control
tele-impedance control |
0.2 | 1 | 2013 | Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device · ICRA 2013 |
Accessibility and assistive technology
assistive technology |
0.2 | 1 | 2013 | Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device · ICRA 2013 |
Human-robot interaction › wearable robot
exoskeleton |
0.2 | 1 | 2013 | Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device · ICRA 2013 |
Accessibility and assistive technology › assistive technology
knee exoskeleton |
0.2 | 1 | 2013 | Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device · ICRA 2013 |
Robotics › Legged, aerial and field robots
legged robots |
0.1 | 1 | 2012 | Hopping at the resonance frequency: A trajectory generation technique for bipedal robots with elastic joints · ICRA 2012 |
Robotics › Motion planning and robot control
trajectory optimization |
0.1 | 1 | 2012 | Hopping at the resonance frequency: A trajectory generation technique for bipedal robots with elastic joints · ICRA 2012 |
Robotics › Motion planning and robot control › trajectory planning
zero-moment point trajectory generation |
0.1 | 1 | 2012 | Hopping at the resonance frequency: A trajectory generation technique for bipedal robots with elastic joints · ICRA 2012 |
Robotics › Legged, aerial and field robots
humanoid robot |
0.1 | 1 | 2011 | The design of the lower body of the compliant humanoid robot "cCub" · ICRA 2011 |
Robotics › Robot manipulation › actuator design › compliant actuator
series elastic actuator |
0.1 | 1 | 2011 | The design of the lower body of the compliant humanoid robot "cCub" · ICRA 2011 |
Human-robot interaction › physical human-robot interaction
admittance control |
0.1 | 1 | 2010 | Control strategies for ankle rehabilitation using a high performance ankle exerciser · ICRA 2010 |
Health and well-being technologies › rehabilitation technology › rehabilitation robotics
ankle rehabilitation |
0.1 | 1 | 2010 | Control strategies for ankle rehabilitation using a high performance ankle exerciser · ICRA 2010 |
Health and well-being technologies › rehabilitation technology
rehabilitation robotics |
0.1 | 1 | 2010 | Control strategies for ankle rehabilitation using a high performance ankle exerciser · ICRA 2010 |
Human-robot interaction › assistive robotics
robot-assisted therapy |
0.1 | 1 | 2010 | Control strategies for ankle rehabilitation using a high performance ankle exerciser · ICRA 2010 |
Robotics › Robot manipulation › robot design
manipulator design |
0.1 | 1 | 2009 | A high performance 2-dof over-actuated parallel mechanism for ankle rehabilitation · ICRA 2009 |
Robotics › Robot manipulation
parallel manipulator |
0.1 | 1 | 2009 | A high performance 2-dof over-actuated parallel mechanism for ankle rehabilitation · ICRA 2009 |
Robotics › Motion planning and robot control › robot control
compliant actuation |
0.0 | 1 | 2011 | The design of the lower body of the compliant humanoid robot "cCub" · ICRA 2011 |
Robotics › Robot manipulation › compliant manipulation
passive compliance |
0.0 | 1 | 2011 | The design of the lower body of the compliant humanoid robot "cCub" · ICRA 2011 |
Wearable and physiological sensing
electromyography |
0.0 | 1 | 2010 | Control strategies for ankle rehabilitation using a high performance ankle exerciser · ICRA 2010 |
Medical and health informatics › medical robotics
rehabilitation robotics |
0.0 | 1 | 2009 | A high performance 2-dof over-actuated parallel mechanism for ankle rehabilitation · ICRA 2009 |
Methods — techniques the papers use, named apart from their topics
electromyography · 0.4series elastic actuation · 0.3musculoskeletal model · 0.3optimal design · 0.2cable-driven linear actuator · 0.2actuation redundancy · 0.2resonance frequency system identification · 0.1momentum constraints · 0.1series elastic actuator · 0.1position control · 0.1admittance control · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2013 | Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton deviceabstractIn this paper, a knee exoskeleton device and its Tele-Impedance based assistive control scheme is presented. The exoskeleton device is an inherently compliant actuated system that was implemented based on the series elastic actuation (SEA) to provide improved and intrinsically soft interaction behaviour. Details of the exoskeleton design are presented. A detailed musculoskeletal model was developed and experimentally identified in order to map electromyographic signals to the antagonistic muscle torques, acting on the human knee joint. The estimated muscle torques are used in order to determine the user's intent and joint stiffness trend. These reference signals are exploited by a novel Tele-Impedance controller which is applied to a knee exoskeleton device to provide assistance and stiffness augmentation to the user's knee joint. Experimental trials of a standing-up motion task were carried out for evaluation of the proposed control strategy. The results indicate that the proposed knee exoskeleton device and control scheme can effectively generate assistive actions that are intrinsically and naturally controlled by the user muscle activity. Nikos Karavas, Arash Ajoudani, Nikolaos G. Tsagarakis, Jody Alessandro Saglia, Antonio Bicchi, Darwin G. Caldwell |
ICRA | 4 |
| 2012 | Hopping at the resonance frequency: A trajectory generation technique for bipedal robots with elastic jointsabstractIt is known that bipedal robots with passive compliant structures have obvious advantages over stiff robots, as they are able to handle the potential energy management. Therefore, this paper is aimed at presenting a jumping pattern generation method that takes advantage of this property via the utilization of the base resonance frequency, which is of special importance. To begin with, the resonance frequency is determined through a system identification procedure on our actual robot. Consequentially, the vertical component of the CoM is generated via a periodic function in which the resonance frequency is employed. The horizontal component of the CoM is obtained using the ZMP criterion to guarantee the dynamic balance. Having obtained the necessary elements of the CoM trajectory within an analytical manner, joint motions are computed with the help of translational and angular momenta constraints. In order to validate the method, two legged jumping experiments are conducted on our actual compliant robot. In conclusion, we observed repetitive, continuous, and dynamically equilibrated jumping cycles with feasible landing phases. Barkan Ugurlu, Jody Alessandro Saglia, Nikolaos G. Tsagarakis, Darwin G. Caldwell |
ICRA | 2 |
| 2011 | The design of the lower body of the compliant humanoid robot "cCub"abstractThe “iCub ”is a robotic platform that was developed by the RobotCub [1] consortium to provide the cognition research community with an open “child-like ”humanoid platform for understanding and development of cognitive systems [1]. In this paper we present the mechanical realization of the lower body developed for the “cCub ”humanoid robot, a derivative of the original “iCub”, which has passive compliance in the major joints of the legs. It is hypothesized that this will give to the robot high versatility to cope with unpredictable disturbance ranging from small uneven terrain variations to unexpected collisions or even accidental falls. As part of the AMARSI European project, the passive compliance of this newly developed robot will be exploited for safer interaction, energy efficient and more aggressive damage-safe learning. The passive compliant actuation module used is a compact unit based on the series elastic actuator principle (SEA). In addition to the passive compliance the “cCub ”design includes other significant updates over the original prototype such as full joint state sensing including joint torque sensing and improved range of motion and torque capabilities. In this paper, the new leg mechanisms of the “cCub ”robot are introduced. Nikolaos G. Tsagarakis, Zhibin Li 0001, Jody Alessandro Saglia, Darwin G. Caldwell |
ICRA | 3 |
| 2010 | Control strategies for ankle rehabilitation using a high performance ankle exerciserabstractThis paper presents the control architecture and preliminary experimental results of a high performance parallel robot used for ankle rehabilitation. The goal of this work was to design suitable control algorithms for diagnostic, training and rehabilitation of the ankle in presence of musculoskeletal injuries. A position control scheme is used for patient-passive exercises while an admittance control technique is used to perform patient-active exercises with and without motion assistance. The design of the control algorithms is based on the analysis of the rehabilitation protocol taking into account the dynamics of the system and the dynamics of the interaction between the human and the robot. Electromyographic (EMG) signals are used to evaluate patient's effort during training/exercising. The results indicate the great potential of the rehabilitation device as a tool to fasten and improve the ankle therapies outcome. Jody Alessandro Saglia, Nikolaos G. Tsagarakis, Jian S. Dai 0001, Darwin G. Caldwell |
ICRA | 1 |
| 2009 | A high performance 2-dof over-actuated parallel mechanism for ankle rehabilitationabstractThis paper presents the mechanical design of an ankle rehabilitation robotic device based on a 2-dof, redundantly actuated parallel mechanism. The parallel mechanism introduced in this paper has the advantage of mechanical and kinematic simplicity when compared to existing platforms while at the same time it is fully capable of carrying out all the exercises required by ankle rehabilitation protocols. The proposed device makes use of actuation redundancy to eliminate singularity and greatly improve the workspace dexterity. In addition, the requirements for high torque capacity and back-drivability are satisfied with the employment of a custom made cable driven linear electric actuator that combines the high force capacity with excellent back-drivability. The analysis undergoes the optimal design towards the maximization of manipulator workspace, dexterity, torque output and compactness of the device. Finally, the performance of the custom linear actuator and the prototype of the rehabilitation device are shown. Jody Alessandro Saglia, Nikolaos G. Tsagarakis, Jian S. Dai 0001, Darwin G. Caldwell |
ICRA | 1 |