Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Tibor Horvath

dblp:68/6924 · DBLP profile ↗
← Back
3ranked-venue papers
3as first author
0since 2021 · last 2008
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Systems, architecture and hardware · 3 · 3 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer architecture, parallel and distributed computing, and storage systems
1 paper
Energy-efficient computing · 77% High-performance computing · 12% Distributed systems · 12%

Topics — the 3 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Energy-efficient computing › voltage scaling
dynamic voltage scaling
0.112007
Dynamic Voltage Scaling in Multitier Web Servers with End-to-End Delay Control · IEEE Trans. Computers 2007
Energy-efficient computing
power management
0.112007
Dynamic Voltage Scaling in Multitier Web Servers with End-to-End Delay Control · IEEE Trans. Computers 2007
High-performance computing › cluster computing
server cluster
0.012007
Dynamic Voltage Scaling in Multitier Web Servers with End-to-End Delay Control · IEEE Trans. Computers 2007

Methods — techniques the papers use, named apart from their topics

optimization · 0.1end-to-end delay control · 0.1
YearPublicationVenuePosition
2008 Multi-mode energy management for multi-tier server clusters
abstract
This paper presents an energy management policy for reconfigurable clusters running a multi-tier application, exploiting DVS together with multiple sleep states. We develop a theoretical analysis of the corresponding power optimization problem and design an algorithm around the solution. Moreover, we rigorously investigate selection of the optimal number of spare servers for each power state, a problem that has only been approached in an ad-hoc manner in current policies.
Tibor Horvath, Kevin Skadron
PACT1
2007 Enhancing Energy Efficiency in Multi-tier Web Server Clusters via Prioritization
abstract
This paper investigates the design issues and energy savings benefits of service prioritization in multi-tier Web server clusters. In many services, classes of clients can be naturally assigned different priorities based on their performance requirements. We show that if the whole multi-tier system is effectively prioritized, additional power and energy savings are realizable while keeping an existing cluster-wide energy management technique, through exploiting the different performance requirements of separate service classes. We find a simple prioritization scheme to be highly effective without requiring intrusive modifications to the system. In order to quantify its benefits, we perform extensive experimental evaluation on a real testbed. It is shown that the scheme significantly improves both total system power savings and energy efficiency, at the same time as improving throughput and enabling the system to meet per-class performance requirements.
Tibor Horvath, Kevin Skadron, Tarek F. Abdelzaher
IPDPS1
2007 Dynamic Voltage Scaling in Multitier Web Servers with End-to-End Delay Control
abstract
The energy and cooling costs of Web server farms are among their main financial expenditures. This paper explores the benefits of dynamic voltage scaling (DVS) for power management in server farms. Unlike previous work, which addressed DVS on individual servers and on load-balanced server replicas, this paper addresses DVS in multistage service pipelines. Contemporary Web server installations typically adopt a three-tier architecture in which the first tier presents a Web interface, the second executes scripts that implement business logic, and the third serves database accesses. From a user's perspective, only the end-to-end response across the entire pipeline is relevant. This paper presents a rigorous optimization methodology and an algorithm for minimizing the total energy expenditure of the multistage pipeline subject to soft end-to-end response-time constraints. A distributed power management service is designed and evaluated on a real three-tier server prototype for coordinating DVS settings in a way that minimizes global energy consumption while meeting end-to-end delay constraints. The service is shown to consume as much as 30 percent less energy compared to the default (Linux) energy saving policy
Tibor Horvath, Tarek F. Abdelzaher, Kevin Skadron, Xue (Steve) Liu
IEEE Trans. Computers1