EDBT 2026 Demo / reviewers in the wild / expert
Nicolas Lauzier
dblp:70/7793
· DBLP profile ↗
4ranked-venue papers
3as first author
0since 2021 · last 2011
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 4 · 3 first-authorSystems, architecture and hardware · 4 · 3 first-author
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
3 papers |
Robot manipulation · 61% Motion planning and robot control · 39% | |
| Human-computer interaction and pervasive computing
4 papers |
Human-robot interaction · 82% Haptics and multimodal interaction · 18% |
Topics — the 5 heaviest of 6, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Human-robot interaction
physical human-robot interaction |
0.4 | 4 | 2011 | Series Clutch Actuators for safe physical human-robot interaction · ICRA 2011 3-DOF Cartesian Force Limiting Device Based on the Delta architecture for safe physical human-robot interaction · ICRA 2010 2 DOF cartesian force limiting device for safe physical human-robot interaction · ICRA 2009 |
Robotics › Motion planning and robot control
robot control |
0.1 | 1 | 2011 | Series Clutch Actuators for safe physical human-robot interaction · ICRA 2011 |
Robotics › Motion planning and robot control › robot control › optimization-based control
torque optimization |
0.1 | 1 | 2011 | Series Clutch Actuators for safe physical human-robot interaction · ICRA 2011 |
Haptics and multimodal interaction › tactile sensing
contact sensing |
0.1 | 1 | 2009 | A flexible robot skin for safe physical human robot interaction · ICRA 2009 |
Robotics › Robot manipulation
parallel manipulator |
0.1 | 2 | 2010 | 3-DOF Cartesian Force Limiting Device Based on the Delta architecture for safe physical human-robot interaction · ICRA 2010 2 DOF cartesian force limiting device for safe physical human-robot interaction · ICRA 2009 |
Methods — techniques the papers use, named apart from their topics
torque limiter · 0.7isotropy optimization · 0.2gravity compensation · 0.2limit switch · 0.2shape deposition manufacturing · 0.1pressure sensitive rubber · 0.1conductive ink sensors · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2011 | Series Clutch Actuators for safe physical human-robot interactionabstractThis paper presents the design, implementation and control of a device intented to mechanically improve the safety of serial robots interacting with humans. The device consists of an electronically adjustable torque limiter placed in series with each actuator, referred to as a Series Clutch Actuator (SCA). By appropriately adjusting the limit torques according to the robot's configuration, the maximum static force that the robot can apply to its environment at the Tool Centre Point (TCP) can be limited to a prescribed safe level. If a limit torque is exceeded, the SCA slips and an emergency stop is triggered while the inertia located upstream from the SCA in the kinematic chain is mechanically disconnected. A method is presented to determine the optimal limit torques that maximize the isotropically achievable force (which can be applied in all directions without triggering any SCA) while satisfying the safe force limit. An approach to optimize the pose of a redundant robot in order to maximize the isotropically achievable force while preserving a safe maximum force threshold is also proposed. The design and fabrication of a torque limiter using a large number of friction discs is presented. Finally, the mechanisms are implemented into a 4-DOF redundant serial arm and preliminary experimental results are presented. Nicolas Lauzier, Clément Gosselin |
ICRA | 1 |
| 2010 | 3-DOF Cartesian Force Limiting Device Based on the Delta architecture for safe physical human-robot interactionabstractThis paper presents a device that significantly improves the safety of ceiling-mounted robots whose end effector orientation remains constant with respect to the vertical direction (e.g. Scara-type robots). The device consists of a three-degree-of-freedom (DOF) parallel mechanism with the Delta architecture on which the revolute actuators have been replaced with torque limiters. The resulting Cartesian force limiting device (CFLD) is implemented as a mechanical connection between the robot and the effector. It is rigid unless excessive forces are applied on the end effector, for example during a collision. The magnitude of force that activates the mechanism is set by properly adjusting the threshold of the torque limiters. Furthermore, a collision can be rapidly detected with a limit switch placed on one of the links of the mechanism and a signal can be sent directly to brakes that will stop the robot, without passing through a controller and thus improving the reliability and reaction-time of the safety system. By mechanically disconnecting the robot from its end effector, the device ensures that the person involved in the collision is only subjected to the inertia of the end effector and thus potential injuries are greatly reduced. This work is the extension of a previous 2-DOF CFLD that was sensitive only to horizontal forces. The new architecture reacts to collisions occuring in any direction and is geometrically optimized for the proposed application. Also, means to achieve gravitity compensation are proposed. Nicolas Lauzier, Clément Gosselin |
ICRA | 1 |
| 2009 | A flexible robot skin for safe physical human robot interactionabstractProviding contact sensing on the whole body of a robot is a key feature to increase the safety level of physical human-robot interaction. In this paper, a new robot skin capable of sensing multiple contact locations is presented. The motivation behind the proposed design is to produce a relatively inexpensive skin having the capability to provide the spatial location of collisions and also to add compliance to the robot's external cover. The resulting device is a thin flexible sensor sheet made of polyimide films with electrically conductive ink and a pressure sensitive conductive rubber sheet. The problem of internal wire routing is circumvented by the use of conductive ink and a circuit is proposed to minimize the number of output wires. To provide collision absorption and mechanical robustness, the sensor is embedded in different layers of polyurethane using shape deposition manufacturing (SDM). The paper presents the design and the fabrication process of the skin but also some experimental results on the determination of the mechanical properties of the resulting sensor as well as its potential for increasing human safety during human robot interaction. Vincent Duchaine, Nicolas Lauzier, Mathieu Baril, Marc-Antoine Lacasse, Clément Gosselin |
ICRA | 2 |
| 2009 | 2 DOF cartesian force limiting device for safe physical human-robot interactionabstractThis paper presents a device that significantly increases the safety level of suspended robots whose end-effector orientation remains constant with respect to the vertical direction (e.g. Scara-type suspended robots). The device is a two-degree-of-freedom (DOF) parallel mechanism with a parallepipedic architecture on which two revolute joints have been replaced with commercially available torque limiters. The device is implemented as a mechanical connection between the robot and the effector. It is rigid unless excessive horizontal forces are applied on the end-effector, for example during a collision. The level of force that activates the mechanism is set by properly adjusting the threshold of the torque limiters. Furthermore, a collision can be rapidly detected with a limit switch placed on one of the links of the mechanism and a signal can be sent directly to brakes that will stop the robot, without passing through a controller and thus improving the reliability and reaction-time of the safety system. By mechanically disconnecting the robot from its end-effector, the device ensures that the person involved in the collision is only subjected to the inertia of the end-effector and thus potential injuries are greatly reduced. A prototype of the proposed device has been built to validate the concept and to study its behaviour for collisions with different velocities and orientations. Nicolas Lauzier, Martin Grenier, Clément Gosselin |
ICRA | 1 |