Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Pieter M. J. van der Zwet

dblp:71/2808 · DBLP profile ↗
← Back
2ranked-venue papers
1as first author
0since 2021 · last 2000
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Graphics, computer vision, multimedia, augmented reality and games · 1Applied, interdisciplinary, general and emerging computing · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer graphics and multimedia
1 paper
Image and video processing · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Image and video processing › image segmentation › clustering-based segmentation
fuzzy clustering segmentation
0.012000
A multiresolution image segmentation technique based on pyramidal segmentation and fuzzy clustering · IEEE Trans. Image Process. 2000
Image and video processing
image segmentation
0.012000
A multiresolution image segmentation technique based on pyramidal segmentation and fuzzy clustering · IEEE Trans. Image Process. 2000
Image and video processing › image segmentation › hierarchical segmentation
multiresolution segmentation
0.012000
A multiresolution image segmentation technique based on pyramidal segmentation and fuzzy clustering · IEEE Trans. Image Process. 2000
Medical and health informatics
cardiac image analysis
0.012000
A multiresolution image segmentation technique based on pyramidal segmentation and fuzzy clustering · IEEE Trans. Image Process. 2000

Methods — techniques the papers use, named apart from their topics

pyramidal segmentation · 0.1fuzzy c-means clustering · 0.1cluster validity functional · 0.1
YearPublicationVenuePosition
2000 A multiresolution image segmentation technique based on pyramidal segmentation and fuzzy clustering
abstract
In this paper, an unsupervised image segmentation technique is presented, which combines pyramidal image segmentation with the fuzzy c-means clustering algorithm. Each layer of the pyramid is split into a number of regions by a root labeling technique, and then fuzzy c-means is used to merge the regions of the layer with the highest image resolution. A cluster validity functional is used to find the optimal number of objects automatically. Segmentation of a number of synthetic as well as clinical images is illustrated and two fully automatic segmentation approaches are evaluated, which determine the left ventricular volume (LV) in 140 cardiovascular magnetic resonance (MR) images. First fuzzy c-means is applied without pyramids. In the second approach the regions generated by pyramidal segmentation are merged by fuzzy c-means. The correlation coefficients of manually and automatically defined LV lumen of all 140 and 20 end-diastolic images were equal to 0.86 and 0.79, respectively, when images were segmented with fuzzy c-means alone. These coefficients increased to 0.90 and 0.93 when the pyramidal segmentation was combined with fuzzy c-means. This method can be applied to any dimensional representation and at any resolution level of an image series. The evaluation study shows good performance in detecting LV lumen in MR images.
M. Ramze Rezaee, Pieter M. J. van der Zwet, Boudewijn P. F. Lelieveldt, Rob J. van der Geest, Johan H. C. Reiber
IEEE Trans. Image Process.2
1998 Derivation of optimal filters for the detection of coronary arteries
abstract
In this paper optimal filters for the detection of coronary arteries with a diameter range of 0.5-6.0 mm in digital X-ray images are derived using a computational approach. This approach is based on the two requirements for optimal detection. First, the filter should maximize the number of detected true edges and minimize the number of detected false edges. Second, if an edge has been detected, its position should be as close as possible to the true edge position in the image. Since the grey value profile in a digital X-ray image associated with an arterial vessel is asymmetric, the theory on edge detection derived by Canny has been expanded with two additional boundary constraints to make it suitable for the derivation of filters for asymmetric edges. It is demonstrated that it is possible to derive optimal filters for coronary segments. The localization error, defined by the square root of the sum of the squared systematic and random errors in the assessment of the arterial diameter, depends on the size of the coronary artery and the amount of noise in the image. In this paper, an evaluation study is described to assess the relationship between localization error and the amount of noise upon the vessel profile. For that purpose, an analytical description of the vessel profile in an angiographic image was derived. For the larger arteries the relation between noise and localization error was found to be linear and no systematic over- or underestimations were observed, even if the noise level was very high. However, it can be shown that the smallest diameter that can be measured depends on the amount of noise present in the data. Even for images that contain only a low amount of noise, arterial diameters below 0.7 mm cannot be measured accurately. If the noise in the image increases, the lowest measurable arterial diameter value also increases. Also the random error increases rapidly for vessel diameters below 1.2 mm, but with a limited amount of noise and a diameter value above 0.7 mm the random error is still acceptable [0.15 mm (21%) for 0.7-mm vessels, 0.06 mm (6%) for 1-mm vessels].
Pieter M. J. van der Zwet, M. Nettesheim, Jan J. Gerbrands, Johan H. C. Reiber
IEEE Trans. Medical Imaging1