Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Samuel Matej

dblp:72/105 · DBLP profile ↗
← Back
12ranked-venue papers
5as first author
0since 2021 · last 2012
0000-0003-1651-0032ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 9 · 4 first-authorGraphics, computer vision, multimedia, augmented reality and games · 3 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
2 papers
Bioinformatics and computational biology · 85% Medical and health informatics · 15%
Computer graphics and multimedia
3 papers
Image and video processing · 100%
Theoretical computer science
1 paper
Information theory · 100%

Topics — the 9 heaviest of 9, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Image and video processing
image reconstruction
0.132004
Overview of methods for image reconstruction from projections in emission computed tomography · Proc. IEEE 2003
Relevance of statistically significant differences between reconstruction algorithms · IEEE Trans. Image Process. 1996
3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004
Bioinformatics and computational biology › structural biology › cryo-electron microscopy
3d reconstruction
0.012004
3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004
Bioinformatics and computational biology › structural biology
cryo-electron microscopy
0.012004
3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004
Bioinformatics and computational biology
structural biology
0.012004
3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004
Image and video processing › image reconstruction
reconstruction from projections
0.012003
Overview of methods for image reconstruction from projections in emission computed tomography · Proc. IEEE 2003
Information theory
hypothesis testing
0.011996
Relevance of statistically significant differences between reconstruction algorithms · IEEE Trans. Image Process. 1996
Image and video processing › image reconstruction
iterative reconstruction
0.012004
3-D reconstruction of 2-D crystals in real space · IEEE Trans. Image Process. 2004
Medical and health informatics
medical imaging
0.012003
Overview of methods for image reconstruction from projections in emission computed tomography · Proc. IEEE 2003
Medical and health informatics › medical imaging › nuclear medicine imaging
positron emission tomography
0.012003
Overview of methods for image reconstruction from projections in emission computed tomography · Proc. IEEE 2003

Methods — techniques the papers use, named apart from their topics

real-space iterative reconstruction · 0.1projection constraints · 0.1iterative reconstruction algorithms · 0.1inverse problem methods · 0.1statistical hypothesis testing · 0.0relevance testing · 0.0
YearPublicationVenuePosition
2012 Comparison of List-Mode and DIRECT Approaches for Time-of-Flight PET Reconstruction
abstract
Early clinical results with time-of-flight (TOF) positron emission tomography (PET) systems have demonstrated the advantages of TOF information in PET reconstruction. Reconstruction approaches in TOF-PET systems include list-mode and binned iterative algorithms as well as confidence-weighted analytic methods. List-mode iterative TOF reconstruction retains the resolutions of the data in the spatial and temporal domains without any binning approximations but is computationally intensive. We have developed an approach [DIRECT (direct image reconstruction for TOF)] to speed up TOF-PET reconstruction that takes advantage of the reduced angular sampling requirement of TOF data by grouping list-mode data into a small number of azimuthal views and co-polar tilts and depositing the grouped events into histo-images, arrays with the sampling and geometry of the final image. All physical effects are included in the system model and deposited in the same histo-image structure. Using histo-images allows efficient computation during reconstruction without ray-tracing or interpolation operations. The DIRECT approach was compared with 3-D list-mode TOF ordered subsets expectation maximization (OSEM) reconstruction for phantom and patient data taken on the University of Pennsylvania research LaBr (3) TOF-PET scanner. The total processing and reconstruction time for these studies with DIRECT without attention to code optimization is approximately 25%-30% that of list-mode TOF-OSEM to achieve comparable image quality. Furthermore, the reconstruction time for DIRECT is independent of the number of events and/or sizes of the spatial and TOF kernels, while the time for list-mode TOF-OSEM increases with more events or larger kernels. The DIRECT approach is able to reproduce the image quality of list-mode iterative TOF reconstruction both qualitatively and quantitatively in measured data with a reduced time.
Margaret E. Daube-Witherspoon, Samuel Matej, Matthew E. Werner, Suleman Surti, Joel S. Karp
IEEE Trans. Medical Imaging2
2010 Fisher Information-Based Evaluation of Image Quality for Time-of-Flight PET
abstract
The use of time-of-flight (TOF) information during positron emission tomography (PET) reconstruction has been found to improve the image quality. In this work we quantified this improvement using two existing methods: 1) a very simple analytical expression only valid for a central point in a large uniform disk source and 2) efficient analytical approximations for postfiltered maximum likelihood expectation maximization (MLEM) reconstruction with a fixed target resolution, predicting the image quality in a pixel or in a small region of interest based on the Fisher information matrix. Using this latter method the weighting function for filtered backprojection reconstruction of TOF PET data proposed by C. Watson can be derived. The image quality was investigated at different locations in various software phantoms. Simplified as well as realistic phantoms, measured both with TOF PET systems and with a conventional PET system, were simulated. Since the time resolution of the system is not always accurately known, the effect on the image quality of using an inaccurate kernel during reconstruction was also examined with the Fisher information-based method. First, we confirmed with this method that the variance improvement in the center of a large uniform disk source is proportional to the disk diameter and inversely proportional to the time resolution. Next, image quality improvement was observed in all pixels, but in eccentric and high-count regions the contrast-to-noise ratio (CNR) increased less than in central and low- or medium-count regions. Finally, the CNR was seen to decrease when the time resolution was inaccurately modeled (too narrow or too wide) during reconstruction. Although the maximum CNR is not very sensitive to the time resolution error, using an inaccurate TOF kernel tends to introduce artifacts in the reconstructed image.
Kathleen Vunckx, Samuel Matej, Michel Defrise, Johan Nuyts
IEEE Trans. Medical Imaging3
2009 Efficient 3-D TOF PET Reconstruction Using View-Grouped Histo-Images: DIRECT - Direct Image Reconstruction for TOF
abstract
For modern time-of-flight (TOF) positron emission tomography (PET) systems, in which the number of possible lines of response and TOF bins is much larger than the number of acquired events, the most appropriate reconstruction approaches are considered to be list-mode methods. However, their shortcomings are relatively high computational costs for reconstruction and for sensitivity matrix calculation. Efficient treatment of TOF data within the proposed DIRECT approach is obtained by 1) angular (azimuthal and co-polar) grouping of TOF events to a set of views as given by the angular sampling requirements for the TOF resolution, and 2) deposition (weighted-histogramming) of these grouped events, and correction data, into a set of "histo-images," one histo-image per view. The histo-images have the same geometry (voxel grid, size and orientation) as the reconstructed image. The concept is similar to the approach involving binning of the TOF data into angularly subsampled histo-projections-projections expanded in the TOF directions. However, unlike binning into histo-projections, the deposition of TOF events directly into the image voxels eliminates the need for tracing and/or interpolation operations during the reconstruction. Together with the performance of reconstruction operations directly in image space, this leads to a very efficient implementation of TOF reconstruction algorithms. Furthermore, the resolution properties are not compromised either, since events are placed into the image elements of the desired size from the beginning. Concepts and efficiency of the proposed data partitioning scheme are demonstrated in this work by using the DIRECT approach in conjunction with the row-action maximum-likelihood (RAMLA) algorithm.
Samuel Matej, Suleman Surti, Shridhar Jayanthi, Margaret E. Daube-Witherspoon, Robert M. Lewitt, Joel S. Karp
IEEE Trans. Medical Imaging1
2006 Fourier-Based Reconstruction for Fully 3-D PET: Optimization of Interpolation Parameters
abstract
Fourier-based approaches for three-dimensional (3-D) reconstruction are based on the relationship between the 3-D Fourier transform (FT) of the volume and the two-dimensional (2-D) FT of a parallel-ray projection of the volume. The critical step in the Fourier-based methods is the estimation of the samples of the 3-D transform of the image from the samples of the 2-D transforms of the projections on the planes through the origin of Fourier space, and vice versa for forward-projection (reprojection). The Fourier-based approaches have the potential for very fast reconstruction, but their straightforward implementation might lead to unsatisfactory results if careful attention is not paid to interpolation and weighting functions. In our previous work, we have investigated optimal interpolation parameters for the Fourier-based forward and back-projectors for iterative image reconstruction. The optimized interpolation kernels were shown to provide excellent quality comparable to the ideal sinc interpolator. This work presents an optimization of interpolation parameters of the 3-D direct Fourier method with Fourier reprojection (3D-FRP) for fully 3-D positron emission tomography (PET) data with incomplete oblique projections. The reprojection step is needed for the estimation (from an initial image) of the missing portions of the oblique data. In the 3D-FRP implementation, we use the gridding interpolation strategy, combined with proper weighting approaches in the transform and image domains. We have found that while the 3-D reprojection step requires similar optimal interpolation parameters as found in our previous studies on Fourier-based iterative approaches, the optimal interpolation parameters for the main 3D-FRP reconstruction stage are quite different. Our experimental results confirm that for the optimal interpolation parameters a very good image accuracy can be achieved even without any extra spectral oversampling, which is a common practice to decrease errors caused by interpolation in Fourier reconstruction.
Samuel Matej, Ivan G. Kazantsev
IEEE Trans. Medical Imaging1
2004 3-D reconstruction of 2-D crystals in real space
abstract
A new algorithm for three-dimensional reconstruction of two-dimensional crystals from projections is presented, and its applicability to biological macromolecules imaged using transmission electron microscopy (TEM) is investigated. Its main departures from the traditional approach is that it works in real space, rather than in Fourier space, and it is iterative. This has the advantage of making it convenient to introduce additional constraints (such as the support of the function to be reconstructed, which may be known from alternative measurements) and has the potential of more accurately modeling the TEM image formation process. Phantom experiments indicate the superiority of the new approach even without the introduction of constraints in addition to the projection data.
Roberto Marabini, Carlos Oscar Sánchez Sorzano, Samuel Matej, José-Jesús Fernández, José María Carazo, Gabor T. Herman
IEEE Trans. Image Process.3
2004 Iterative tomographic image reconstruction using Fourier-based forward and back-projectors
abstract
Iterative image reconstruction algorithms play an increasingly important role in modern tomographic systems, especially in emission tomography. With the fast increase of the sizes of the tomographic data, reduction of the computation demands of the reconstruction algorithms is of great importance. Fourier-based forward and back-projection methods have the potential to considerably reduce the computation time in iterative reconstruction. Additional substantial speed-up of those approaches can be obtained utilizing powerful and cheap off-the-shelf fast Fourier transform (FFT) processing hardware. The Fourier reconstruction approaches are based on the relationship between the Fourier transform of the image and Fourier transformation of the parallel-ray projections. The critical two steps are the estimations of the samples of the projection transform, on the central section through the origin of Fourier space, from the samples of the transform of the image, and vice versa for back-projection. Interpolation errors are a limitation of Fourier-based reconstruction methods. We have applied min-max optimized Kaiser-Bessel interpolation within the nonuniform FFT (NUFFT) framework and devised ways of incorporation of resolution models into the Fourier-based iterative approaches. Numerical and computer simulation results show that the min-max NUFFT approach provides substantially lower approximation errors in tomographic forward and back-projection than conventional interpolation methods. Our studies have further confirmed that Fourier-based projectors using the NUFFT approach provide accurate approximations to their space-based counterparts but with about ten times faster computation, and that they are viable candidates for fast iterative image reconstruction.
Samuel Matej, Jeffrey A. Fessler, Ivan G. Kazantsev
IEEE Trans. Medical Imaging1
2003 Overview of methods for image reconstruction from projections in emission computed tomography
abstract
Emission computed tomography (ECT) is a technology for medical imaging whose importance is increasing rapidly. There is a growing appreciation for the value of the functional (as opposed to anatomical) information that is provided by ECT and there are significant advancements taking place, both in the instrumentation for data collection, and in the computer methods for generating images from the measured data. These computer methods are designed to solve the inverse problem known as "image reconstruction from projections". This paper uses the various models of the data collection process as the framework for presenting an overview of the wide variety of methods that have been developed for image reconstruction in the major subfields of ECT, which are positron emission tomography (PET) and single-photon emission computed tomography (SPECT). The overall sequence of the major sections in the paper, and the presentation within each major section, both proceed from the more realistic and general models to those that are idealized and application specific. For most of the topics, the description proceeds from the three-dimensional case to the two-dimensional case. The paper presents a broad overview of algorithms for PET and SPECT, giving references to the literature where these algorithms and their applications are described in more detail.
Robert M. Lewitt, Samuel Matej
Proc. IEEE2
2000 2.5 D Simultaneous Multislice Reconstruction by Iterative Algorithms from Fourier-Rebinned PET data
abstract
True three-dimensional (3-D) volume reconstruction from fully 3-D data in positron emission tomography (PET) has only a limited clinical use because of its large computational burden. Fourier rebinning (FORE) of the fully 3-D data into a set of 2-D sinogram data decomposes the 3-D reconstruction process into multiple 2-D reconstructions of decoupled 2-D image slices, thus substantially decreasing the computational burden even in the case when the 2-D reconstructions are performed by an iterative reconstruction algorithm. On the other hand, the approximations involved in the rebinning combined with the decoupling of the image slices cause a certain reduction of image quality, especially when the signal-to-noise ratio of the data is low. We propose a 2.5-D Simultaneous Multislice Reconstruction approach, based on the series expansion principle, where the volume is represented by the superposition of 3-D spherically symmetric bell-shaped basis functions. It takes advantage of the time reduction due to the use of the FORE (2-D) data, instead of the original fully 3-D data, but at the same time uses a 3-D iterative reconstruction approach with 3-D basis functions. The same general approach can be applied to any reconstruction algorithm belonging to the class of series expansion methods (iterative or noniterative) using 3-D basis functions that span multiple slices, and can be used for any multislice sinogram or list mode data whether obtained by a special rebinning scheme or acquired directly by a PET scanner in the 2-D mode using septa. Our studies confirm that the proposed 2.5-D approach provides a considerable improvement in reconstruction quality, as compared to the standard 2-D reconstruction approach, while the reconstruction time is of the same order as that of the 2-D approach and is clinically practical even on a general-purpose computer.
T. Obi, Samuel Matej, Robert M. Lewitt, Gabor T. Herman
IEEE Trans. Medical Imaging2
1996 Relevance of statistically significant differences between reconstruction algorithms
abstract
When comparing reconstruction algorithms, differences in figures of performance merit that are too small to be of any practical relevance may still be statistically significant. We formalize the notion of "relevance" and propose an evaluation methodology in which statistical significance is retained for relevant improvements, but not for irrelevant ones.
Samuel Matej, Sérgio Shiguemi Furuie, Gabor T. Herman
IEEE Trans. Image Process.1
1996 Practical considerations for 3-D image reconstruction using spherically symmetric volume elements
abstract
Spherically symmetric volume elements with smooth tapering of the values near their boundaries are alternatives to the more conventional voxels for the construction of volume images in the computer. Their use, instead of voxels, introduces additional parameters which enable the user to control the shape of the volume element (blob) and consequently to control the characteristics of the images produced by iterative methods for reconstruction from projection data. For images composed of blobs, efficient algorithms have been designed for the projection and discrete back-projection operations, which are the crucial parts of iterative reconstruction methods. The authors have investigated the relationship between the values of the blob parameters and the properties of images represented by the blobs. Experiments show that using blobs in iterative reconstruction methods leads to substantial improvement in the reconstruction performance, based on visual quality and on quantitative measures, in comparison with the voxel case. The images reconstructed using appropriately chosen blobs are characterized by less image noise for both noiseless data and noisy data, without loss of image resolution.
Samuel Matej, Robert M. Lewitt
IEEE Trans. Medical Imaging1
1995 Projection estimation in 3D PET reconstruction: a statistical evaluation
abstract
The purpose of this work is to evaluate the estimation of projection data in fully 3D PET reconstruction. The estimation is carried out to reduce the effect of the noise prior to the application of a reconstruction algorithm and it is based on a non-linear operator that takes into account the Poisson nature of the noise. The evaluation is statistical, based on a set of 3D phantoms and on numerical observers for some typical medical tasks such as total uptake in regions of interest and detectability of hot and cold spots. Our work demonstrates that, for the studied tasks, the projection data estimation is an efficacious approach to fully 3D PET reconstruction.
Sérgio Shiguemi Furuie, Gabor T. Herman, Nelson D. A. Mascarenhas, Samuel Matej
ICIP4
1993 On the possibility of direct Fourier reconstruction from divergent-beam projections
abstract
A great number of tomographic systems, especially those equipped with fast data acquisition techniques, scan the objects investigated by divergent (fan) X-ray beams. Fan-beam projection data require special reconstruction techniques to be implemented. Among reconstruction techniques from parallel projection data, the direct Fourier method (DFM) proved to be one of the most promising ones, especially for high-speed image reconstruction in the high-end 3-D and dynamic tomographic systems. The goal of this work is to answer the topical question: how would direct use of the DFM influence the quality of image reconstruction from the fan-beam data? The formula describing the error caused by such an approximation is derived. The conclusions deduced from the formula are confirmed by computer simulations. The boundary values of data acquisition geometry parameters have been estimated for the case of using the DFM without recalculating the fan-beam data.
Stefano Alliney, Samuel Matej, Ivan Bajla
IEEE Trans. Medical Imaging2