Demo Data from EDBT 2026 / reviewers in the wild / expert
Mitchell J. H. Lum
dblp:72/3642
· DBLP profile ↗
2ranked-venue papers
2as first author
0since 2021 · last 2009
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2 · 2 first-authorSystems, architecture and hardware · 2 · 2 first-author
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
1 paper |
Human-robot interaction · 87% Usability and user experience research · 13% | |
| Artificial intelligence
1 paper |
Robot manipulation · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 7 heaviest of 8, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Human-robot interaction
latency effects |
0.1 | 1 | 2009 | Effect of time delay on telesurgical performance · ICRA 2009 |
Human-robot interaction › teleoperation
surgical robot teleoperation |
0.1 | 1 | 2009 | Effect of time delay on telesurgical performance · ICRA 2009 |
Robotics › Robot manipulation
grasping |
0.0 | 1 | 2004 | Kinematic Optimization of a Spherical Mechanism for a Minimally Invasive Surgical Robot · ICRA 2004 |
Robotics › Robot manipulation
kinematic optimization |
0.0 | 1 | 2004 | Kinematic Optimization of a Spherical Mechanism for a Minimally Invasive Surgical Robot · ICRA 2004 |
Robotics › Robot manipulation › medical robotics
surgical robot arm design |
0.0 | 1 | 2004 | Kinematic Optimization of a Spherical Mechanism for a Minimally Invasive Surgical Robot · ICRA 2004 |
Medical and health informatics › surgical robotics
minimally invasive surgery |
0.0 | 1 | 2004 | Kinematic Optimization of a Spherical Mechanism for a Minimally Invasive Surgical Robot · ICRA 2004 |
Medical and health informatics
surgical robotics |
0.0 | 1 | 2004 | Kinematic Optimization of a Spherical Mechanism for a Minimally Invasive Surgical Robot · ICRA 2004 |
Methods — techniques the papers use, named apart from their topics
statistical significance testing · 0.1jacobian matrix · 0.1isotropy optimization · 0.1forward and inverse kinematics · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2009 | Effect of time delay on telesurgical performanceabstractIn the area of surgical robotics no standard means of performance evaluation has been established. Thousands of surgeons have gone through the SAGES FLS Program, and the psychomotor skill portion of the program is considered the gold standard in laparoscopic skills evaluation. This research describes the use of the FLS block transfer task to evaluate the performance of both surgeons and non-surgeons teleoperating under different time delay conditions on the University of Washington RAVEN Surgical Robot. Time delays of 0 ms, 250 ms, and 500 ms were used and a statistically significant difference in mean block transfer time as well as mean tool tip path length were shown. For this task no significant difference was shown between the surgeon and non-surgeon groups. Clearly surgeon input and feedback is key to surgical robotic system development, but this result implies that non-surgeon subjects can be tested for simple usability evaluations. Mitchell J. H. Lum, Jacob Rosen 0001, Thomas S. Lendvay, Mika N. Sinanan, Blake Hannaford |
ICRA | 1 |
| 2004 | Kinematic Optimization of a Spherical Mechanism for a Minimally Invasive Surgical RobotabstractAdvances in surgical technology allow physicians to more effectively provide care to their patients. Minimally invasive surgery (MIS) has revolutionized the way a significant number of procedures are performed. Advances in technology have led to the fusion of MIS techniques and robotic devices; however, such systems are currently large and cumbersome. By optimizing a spherical mechanism based on in-vivo data collected during MIS procedures, this paper focuses on a bottom-up approach in developing a new class of surgical robot arms. The spherical mechanism is a rotational manipulator with all axes intersecting at the center of the sphere. Locating the rotational center of the mechanism at the MIS port makes this class of mechanism a suitable candidate for the first two links of a surgical robot for both minimally invasive and open surgery. For optimizing the mechanism structure, the forward and inverse kinematics, as well as the Jacobian matrix, were derived. Using the Jacobian, mechanism isotropy was considered as the performance metric. The dexterous workspace (DWS) is defined as a high dexterity region defined by a right circular cone with a vertex angel of 60/spl deg/ in which 95% of the tool motions are contained based on in-vivo measurements. The extended dexterous workspace (EDWS) is defined as the workspace required to reach the entire abdominal cavity with MIS instruments and defined by a cone with an elliptical cross section created by two orthogonal vertex angels of 60/spl deg/ and 90/spl deg/. Optimization across both the DWS and a superset of the EDWS led to a mechanism configuration with link length angles of 74/spl deg/ and 60/spl deg/ that maximizes kinematic performance and compactness. The workspace of this design covers the entire EDWS and is the optimal design for the next generation of surgical manipulator. By directly applying in-vivo experimental data from MIS in order to optimize the spherical manipulator a design that maximizes performance and minimizes size has been developed. A pair of prototype manipulators is developed based on these results. Mitchell J. H. Lum, Jacob Rosen 0001, Mika N. Sinanan, Blake Hannaford |
ICRA | 1 |