Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Randall F. Lind

dblp:73/6514 · DBLP profile ↗
← Back
4ranked-venue papers
1as first author
0since 2021 · last 2009
0000-0001-6447-7201ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 1 first-authorSystems, architecture and hardware · 4 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Robot manipulation · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › robot actuation
hydraulic actuation
0.012004
Modeling and Testing of a Novel Piezoelectric Pump · ICRA 2004
Robotics › Robot manipulation
robot actuation
0.012004
Modeling and Testing of a Novel Piezoelectric Pump · ICRA 2004

Methods — techniques the papers use, named apart from their topics

piezoelectric actuation · 0.0
YearPublicationVenuePosition
2009 Multi-axis foot reaction force/torque sensor for biomedical applications
abstract
To support an Oak Ridge National Laboratory programs exoskeleton project, a unique multi-axis foot force/torque sensor was constructed and tested that has biomedical application such as clinical gait analysis. The challenging aspect of this multi-axis force sensor is that it had to conform to the bending of the human foot, withstand high impact loads, have high force sensitivity, feel comfortable to the human wearer, be integrated into a military style boot, measure the forces on the human foot when either the ball or the heel of the foot is in contact with the ground, respond to both positive and negative loading and have a low overall height and weight. This paper describes the design and testing of this unique sensor.
Randall F. Lind, Lonnie J. Love, John C. Rowe, François G. Pin
IROS1
2009 Mesofluidic actuation for articulated finger and hand prosthetics
abstract
The loss of fingers and hands severely limits career and lifestyle options for the amputee. Unfortunately, while there have been strides made in advancements of upper arm and leg prosthetics, the state of the art in prosthetic hands is lagging far behind. Options are generally limited to claw like devices that provide limited gripping capacity. The overall objective of this paper is to demonstrate a path towards a low-cost prosthetic hand with multiple articulated fingers and a thumb that rivals the human hand in terms of weight, size, dexterity, range of motion, force carrying capacity and speed. We begin with a description of the functional requirements for a human hand. When comparing requirements with actuation technologies, the fluid power approach has the potential to realize a prosthetic hand that rivals a human hand in size, strength and dexterity. We introduce a new actuation technology, mesofluidics, that focuses on miniaturization of fluid power to the meso-scale (mm to cm). As a novel demonstration of the potential for this technology, we describe a proof-of-principle mesofluidic finger that has intrinsic actuation and control (actuators and control valves within the volume of the finger). This finger weighs 63 grams, is sized to the 50thpercentile male finger, has a total of 25 mechanical parts and is capable of providing 10 kg (22 lbs) of pinch force.
Lonnie J. Love, Randall F. Lind, John F. Jansen
IROS2
2009 Development of a remote trauma care assist robot
abstract
In typical teleoperated surgeries, skilled staff are still necessary in the remote surgical room to change manipulator tooling and to manage surgical supply delivery and removal. This paper describes the development of a nurse robot to provide automated support to a teleoperated surgical manipulator system in environments where the presence of skilled surgical support staff may not be practical. The tools must be inserted precisely into a compliant manipulator in a timely manner, and the supplies are diverse in nature. To support experimental investigations and evaluations, a seven degrees-of-freedom commercially available manipulator was selected. The design of novel end-effectors, tool grasping and supply holding features, and tool auto-loading systems for optimum surgical tool changing and supply delivery in minimum time is presented. A novel approach for calibration of the nurse robot among compliant and rigid subsystems and for managing forces during subsystem interaction is described and experimental results using this force management approach are presented. Overall experimental performance data for the nurse robot system during tool changing and supply delivery tasks is also presented to illustrate the feasibility of performing these functions in a remote medical or trauma care-assist cell.
Mark W. Noakes, Randall F. Lind, John F. Jansen, Lonnie J. Love, François G. Pin, Bradley S. Richardson
IROS2
2004 Modeling and Testing of a Novel Piezoelectric Pump
abstract
While there is a wide range of actuation technologies, none currently rivals the overall performance (power density, bandwidth, stress, stroke) of conventional hydraulic actuation [1]. It is well known in the actuation community that the power-to-weight ratios and the power-to-volume ratios of hydraulic actuators are, respectively, around 5 times and 10 to 20 times larger than comparable electric motors. Due to fundamental limitations in the magnetic flux density in the supporting structures and limitations in the heat transfer out of electric actuators, significant changes in these ratios are not likely in the near future [2]. Thermal limitations associated with electric motors do not apply to hydraulic actuators since the hydraulic fluid cools and lubricates the system. However, with all of these virtues, hydraulic actuators have serious practical implementation problems. Typically, servo-based hydraulic actuators are leaky and have generally poor energy efficiencies. This work addresses a new type of electric actuator that combines the best of both the electric and hydraulic mediums.
John F. Jansen, Randall F. Lind, Lonnie J. Love, Joel Chesser
ICRA2