Demo Data from EDBT 2026 / reviewers in the wild / expert
Nathan Bongjoon Cho
dblp:73/8368
· DBLP profile ↗
3ranked-venue papers
0as first author
0since 2021 · last 2011
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 3Systems, architecture and hardware · 3
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
3 papers |
Robot manipulation · 61% 3D vision · 21% Motion planning and robot control · 18% | |
| Interdisciplinary, comprehensive, and emerging computing
3 papers |
Medical and health informatics · 100% |
Topics — the 5 heaviest of 8, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics › image-guided intervention
MRI-guided intervention |
0.1 | 1 | 2011 | A study of needle image artifact localization in confirmation imaging of MRI-guided robotic prostate biopsy · ICRA 2011 |
Robotics › Robot manipulation
medical robotics |
0.1 | 1 | 2010 | Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approaches · ICRA 2010 |
Robotics › Motion planning and robot control › robot control
parallel robot control |
0.1 | 1 | 2010 | Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approaches · ICRA 2010 |
Robotics › Robot manipulation › actuator design
pneumatic actuation |
0.1 | 1 | 2010 | Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approaches · ICRA 2010 |
Medical and health informatics
image-guided intervention |
0.1 | 1 | 2010 | Development and preliminary evaluation of an actuated MRI-compatible robotic device for MRI-guided prostate intervention · ICRA 2010 |
Methods — techniques the papers use, named apart from their topics
quantitative artifact position study · 0.2modular system design · 0.2external damping mechanism · 0.2SNR evaluation · 0.2RF shielding · 0.2
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2011 | A study of needle image artifact localization in confirmation imaging of MRI-guided robotic prostate biopsyabstractRecently several systems for magnetic resonance image (MRI) guided needle placement in the prostate have been reported. In comparison to conventional ultrasound-guided needle placement in the prostate, these MRI-guided systems promise improved targeting accuracy for prostate intervention procedures including biopsy, fiducial marker insertion, injection and focal therapy. In MRI-guided needle interventions, after a needle is inserted, the needle position is often confirmed with a volumetric MRI scan. Commonly used titanium needles are not directly visible in an MR image, but they generate a susceptibility artifact in the immediate neighborhood of the needle. This paper reports the results of a quantitative study of the relation between the true position of titanium biopsy needle and the corresponding needle artifact position in MR images. The titanium needle artifact was found to be displaced 0.38 mm and 0.32 mm shift in scanner's frequency and phase encoding direction, respectively. The artifact at the tip of the titanium needle was observed to bend toward the scanner's B(0) magnetic field direction. Sang-Eun Song, Nathan Bongjoon Cho, Iulian Iordachita, Peter Guion, Gabor Fichtinger, Louis L. Whitcomb |
ICRA | 2 |
| 2010 | Development and preliminary evaluation of an actuated MRI-compatible robotic device for MRI-guided prostate interventionabstractThis paper reports the design, development, and magnetic resonance imaging (MRI) compatibility evaluation of an actuated transrectal prostate robot for MRI-guided intervention. The robot employs an actuated needle guide with the goal of reducing interventional procedure times and increasing needle placement accuracy. The design of the robot, employing piezo-ceramic-motor actuated needle guide positioning and manual needle insertion, is reported. Results of a MRI compatibility study show no reduction of MRI image signal-to-noise-ratio (SNR) with the motors disabled and a 40% to 60% reduction in SNR with the motors enabled. The addition of radio-frequency (RF) shielding is shown to significantly reduce image SNR degradation due to the presence of the robotic device. Axel Krieger, Iulian Iordachita, Sang-Eun Song, Nathan Bongjoon Cho, Peter Guion, Gabor Fichtinger, Louis L. Whitcomb |
ICRA | 4 |
| 2010 | Development of a pneumatic robot for MRI-guided transperineal prostate biopsy and brachytherapy: New approachesabstractMagnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained. Sang-Eun Song, Nathan Bongjoon Cho, Gregory S. Fischer, Nobuhiko Hata, Clare M. Tempany, Gabor Fichtinger, Iulian Iordachita |
ICRA | 2 |