Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Frank Sauer

dblp:74/4859 · DBLP profile ↗
← Back
14ranked-venue papers
2as first author
0since 2021 · last 2010
0000-0003-2718-6338ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Graphics, computer vision, multimedia, augmented reality and games · 11 · 2 first-authorApplied, interdisciplinary, general and emerging computing · 10 · 2 first-authorHuman-computer interaction and ubiquitous computing · 3Artificial intelligence and machine learning · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer graphics and multimedia
3 papers
Virtual and augmented reality · 84% Rendering · 16%
Computer architecture, parallel and distributed computing, and storage systems
2 papers
Performance modeling and evaluation · 100%
Artificial intelligence
1 paper
3D vision · 100%
Human-computer interaction and pervasive computing
1 paper
Immersive interaction · 100%

Topics — the 8 heaviest of 10, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Virtual and augmented reality › augmented reality
medical augmented reality
0.122006
Reality Augmentation for Medical Procedures: System Architecture, Single Camera Marker Tracking, and System Evaluation · Int. J. Comput. Vis. 2006
A High Performance AR System for Medical Applications · ISMAR 2003
Performance modeling and evaluation
latency measurement
0.112007
Measurement of absolute latency for video see through augmented reality · ISMAR 2007
Virtual and augmented reality
augmented reality
0.112006
Reality Augmentation for Medical Procedures: System Architecture, Single Camera Marker Tracking, and System Evaluation · Int. J. Comput. Vis. 2006
Computer vision › 3D vision
pose estimation
0.012002
Single Camera Tracking of Marker Clusters: Multiparameter Cluster Optimization and Experimental Verification · ISMAR 2002
Virtual and augmented reality › tracking
marker-based tracking
0.012002
Single Camera Tracking of Marker Clusters: Multiparameter Cluster Optimization and Experimental Verification · ISMAR 2002
Immersive interaction
augmented reality interaction
0.012007
Measurement of absolute latency for video see through augmented reality · ISMAR 2007
Virtual and augmented reality › tracking
camera tracking
0.012006
Reality Augmentation for Medical Procedures: System Architecture, Single Camera Marker Tracking, and System Evaluation · Int. J. Comput. Vis. 2006
Computer vision › 3D vision
camera calibration
0.012002
Single Camera Tracking of Marker Clusters: Multiparameter Cluster Optimization and Experimental Verification · ISMAR 2002

Methods — techniques the papers use, named apart from their topics

projective transformation · 0.1cross ratio encoding · 0.1component-based software platform · 0.1XML configuration · 0.1monte carlo simulation · 0.1cluster optimization · 0.1marker tracking · 0.1
YearPublicationVenuePosition
2010 Image-Based Respiratory Motion Compensation for Fluoroscopic Coronary Roadmapping
Yanghai Tsin, Hari Sundar, Frank Sauer
MICCAI (3)4
2007 Measurement of absolute latency for video see through augmented reality
abstract
Latency is a key property of video see through AR systems since users' performance is strongly related to it. However, there is no standard way of latency measurement of an AR system in the literature. We have created a stable and comparable way of estimating the latency in a video see through AR system. The latency is estimated by encoding the time in the image and decoding the time after camera feedback. We have encoded the time as a translation of a circle in the image. The cross ratio has been used as an image feature that is preserved in a projective transformation. The encoding allows for a simple but accurate way of decoding. We show that this way of encoding has an adequate accuracy for latency measurements. As the method allows for a series of automatic measurements we propose to visualize the measurements in a histogram. This histogram reveals meaningful information about the system other than the mean value and standard deviation of the latency. The method has been tested on four different AR systems that use different camera technology, resolution and frame rates.
Tobias Sielhorst, Wu Sa, Ali Kamen, Frank Sauer, Nassir Navab
ISMAR4
2007 Image Guidance of Intracardiac Ultrasound with Fusion of Pre-operative Images
Yiyong Sun, Samuel Kadoury, Yong Li 0010, Matthias John 0001, Jeff Resnick, Gerry Plambeck, Rui Liao, Frank Sauer, Chenyang Xu 0001
MICCAI (1)8
2006 Reality Augmentation for Medical Procedures: System Architecture, Single Camera Marker Tracking, and System Evaluation
Sebastian Vogt 0001, Ali Kamen, Frank Sauer
Int. J. Comput. Vis.3
2006 Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy
Ali Kamen, Peter Bloch, Wolfgang Wein, Michelle Svatos, Frank Sauer
Medical Image Anal.5
2005 Learning Based Non-rigid Multi-modal Image Registration Using Kullback-Leibler Divergence
Christoph Gütter, Chenyang Xu 0001, Frank Sauer, Joachim Hornegger
MICCAI (2)3
2005 A Novel Phantom-Less Spatial and Temporal Ultrasound Calibration Method
Ali Kamen, Frank Sauer
MICCAI (2)2
2004 Characterization of Internal Organ Motion Using Skin Marker Positions
Ali Kamen, Jan Karl Warzelhan, Sebastian Vogt 0001, Daniel Elgort, Christophe Chefd'Hotel, Jeffrey L. Duerk, Jonathan S. Lewin, Frank K. Wacker, Frank Sauer
MICCAI (2)9
2003 A High Performance AR System for Medical Applications
abstract
We report on a new single PC based stereoscopic video-see-through AR system which we developed for medical applications. Recent advances in graphics hardware, memory bandwidth, and computing power of standard PCs made it possible that this system outperforms an earlier version which included 3 networked SGI workstations. We designed and implemented a new AR software platform. It is component based and - in conjunction with XML configuration files - provides efficiency, modularity, and extensibility for fast and robust prototyping of AR applications. The system has a compelling real-time performance with 30 frames/second, displaying stereoscopic augmented video views with XGA resolution.
Sebastian Vogt 0001, Ali Kamen, Frank Sauer, Andreas Keil, Heinrich Niemann
ISMAR3
2003 Local 3D Reconstruction and Augmented Reality Visualization of Free-Hand Ultrasound for Needle Biopsy Procedures
Ali Kamen, Sebastian Vogt 0001, Fred S. Azar, Tobias Sielhorst, Frank Sauer, Heinrich Niemann
MICCAI (2)5
2002 Single Camera Tracking of Marker Clusters: Multiparameter Cluster Optimization and Experimental Verification
abstract
We have built a system for augmented reality visualization based on a single head mounted tracking camera. The camera includes an infrared illuminator and works in conjunction with a set of retro-reflective markers that are placed around the workspace. This marker frame configuration delivers excellent pose information, which translates to stable, jitter-free augmentation. In this article, we describe using the same single camera system for tracking relatively small marker clusters, which can be used for tool or instrument tracking. Tracking of such a marker cluster is more susceptible to noise compared to tracking of a marker frame, mainly due to its small image coverage. The sensitivity to noise is studied using Monte Carlo simulations and verified in an experimental setup. We achieved jitter-free augmentation with an optimized cluster design.
Sebastian Vogt 0001, Ali Kamen, Frank Sauer, Heinrich Niemann
ISMAR3
2002 An Augmented Reality Navigation System with a Single-Camera Tracker: System Design and Needle Biopsy Phantom Trial
Frank Sauer, Ali Kamen, Sebastian Vogt 0001
MICCAI (2)1
2001 A Head-Mounted Display System for Augmented Reality Image Guidance: Towards Clinical Evaluation for iMRI-guided Neurosurgery
Frank Sauer, Ali Kamen, Benedicte Bascle, Gregory J. Rubino
MICCAI1
2000 Exact spiral scan region-of-interest cone beam reconstruction via backprojection
abstract
We present a (spiral + circles) scan cone beam reconstruction algorithm in which image reconstruction proceeds via backprojection in the object space. In principle, the algorithm can reconstruct sectional region-of-interest (ROI) in a long object. The approach is a generalization of the cone beam backprojection technique developed by Kudo and Saito in two aspects: the resource-demanding normalization step in the Kudo and Saito's algorithm is eliminated through the technique of data combination that we published earlier, and the elimination of the restriction that the detector be big enough to capture the entire cone beam projection of the ROI. Restricting the projection data to the appropriate angular range required by data combination can be accomplished by a masking process. Because of the simplification resulting from the elimination of the normalization step, the most time-consuming operations of the algorithm can be approximated by the efficient step of line-by-line ramp filtering the cone beam image in the direction of the scan path, plus a correction image. The correction image, which can be computed exactly, is needed because data combination is not properly matched at the mask boundary when ramp filtering is involved. Empirical two-dimensional (2-D) point spread function (PSF) is developed to improve matching with the correction image which is computed with finite samplings. The use of transition region to further improve matching is introduced. The results of testing the algorithm on simulated phantoms are presented.
Kwok C. Tam, Günter Lauritsch, Katia Sourbelle, Frank Sauer, Bruce Ladendorf
IEEE Trans. Medical Imaging4