Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Eli Paster

dblp:74/8370 · DBLP profile ↗
← Back
1ranked-venue papers
1as first author
0since 2021 · last 2010
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1 · 1 first-authorSystems, architecture and hardware · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Motion planning and robot control · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Motion planning and robot control › robot control
actuator control
0.012010
Closed loop performance of polypyrrole linear contractile actuators · ICRA 2010
Robotics › Motion planning and robot control › robot control › feedback control
closed-loop positioning
0.012010
Closed loop performance of polypyrrole linear contractile actuators · ICRA 2010

Methods — techniques the papers use, named apart from their topics

potentiostat control · 0.1PI control · 0.1
YearPublicationVenuePosition
2010 Closed loop performance of polypyrrole linear contractile actuators
abstract
Conducting polymer actuators such as polypyrrole can generate stresses over 10 times larger than skeletal muscle and have typical repeatable strains between 1% and 12%, making them potential candidates for lightweight, low-cost, robotic applications. Polypyrrole linear actuators under closed loop control have not been previously reported. Here we report the open and closed loop performance of polypyrrole linear contractile actuators evaluated at pre-loaded stresses of 1 MPa to 3 MPa. A standard PI control scheme driving a potentiostat was implemented in conjunction with positioning feedback from a DC/DC linear variable differential transformer (LVDT). A dynamic positioning range of 3400 is reported, with a positioning resolution of 125 nm (0.001% strain) and a maximum repeatable displacement of 427 microns (3.6% strain). The open loop frequency response of actuator strain shows characteristics of a first-order low pass filter with a log gain versus log frequency slope near -1 for frequencies tested between 0.05 Hz to 2 Hz. The closed loop frequency response of actuator strain when tracking a sinusoidal set-point signal of 0.5% strain shows characteristics of a first order system with one zero, with a corner frequency near 0.08 Hz and an operating bandwidth up to 1 Hz. Step responses at various controller output maximum voltages show a reduction in contractile response times by a factor of four, where higher voltages yield faster contractile responses.
Eli Paster, Bryan P. Ruddy, Priam V. Pillai, Ian W. Hunter
ICRA1