Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Antony J. Hodgson

dblp:80/5965 · DBLP profile ↗
← Back
19ranked-venue papers
2as first author
0since 2021 · last 2019
0000-0002-3107-581XORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 14 · 1 first-authorGraphics, computer vision, multimedia, augmented reality and games · 13Artificial intelligence and machine learning · 4Systems, architecture and hardware · 3Human-computer interaction and ubiquitous computing · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer graphics and multimedia
1 paper
Audio and music processing · 100%
Interdisciplinary, comprehensive, and emerging computing
3 papers
Medical and health informatics · 100%
Human-computer interaction and pervasive computing
1 paper
Haptics and multimodal interaction · 87% Health and well-being technologies · 13%
Artificial intelligence
2 papers
Robot manipulation · 80% Motion planning and robot control · 20%

Topics — the 9 heaviest of 11, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › computational pathology
tissue identification
0.112019
Automatic Identification of Hard and Soft Bone Tissues by Analyzing Drilling Sounds · IEEE ACM Trans. Audio Speech Lang. Process. 2019
Robotics › Robot manipulation
robot design
0.112005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Medical and health informatics › surgical robotics
orthopedic surgical robot
0.112005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Medical and health informatics
surgical robotics
0.112005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Haptics and multimodal interaction
haptic rendering
0.012004
Simulating Cheap Hardware: a Platform for Evaluating Cost-performance Trade-offs in Haptic Hardware Design · ICRA 2004
Medical and health informatics › surgical robotics
robot-assisted surgery
0.012001
Accurate Femoral Canal Shaping in Total Hip Arthroplasty using a Mini-Robot · ICRA 2001
Robotics › Motion planning and robot control
robot control
0.012005
Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery · ICRA 2005
Health and well-being technologies › medical simulation
surgical simulation
0.012004
Simulating Cheap Hardware: a Platform for Evaluating Cost-performance Trade-offs in Haptic Hardware Design · ICRA 2004
Robotics › Robot manipulation › medical robotics
surgical robotics
0.012001
Accurate Femoral Canal Shaping in Total Hip Arthroplasty using a Mini-Robot · ICRA 2001

Methods — techniques the papers use, named apart from their topics

wavelet packet transform · 0.8support vector machine · 0.8random forest · 0.8logistic regression · 0.8hidden markov model · 0.8mechanical braking system · 0.1gear transmission · 0.1registration gauge · 0.1mini-robot · 0.1hardware degradation simulation · 0.0
YearPublicationVenuePosition
2019 Comparative Evaluation of Hand-Engineered and Deep-Learned Features for Neonatal Hip Bone Segmentation in Ultrasound
Houssam El-Hariri, Kishore Mulpuri, Antony J. Hodgson, Rafeef Garbi
MICCAI (2)3
2019 Automatic Identification of Hard and Soft Bone Tissues by Analyzing Drilling Sounds
abstract
Our purpose is to assess if bone drilling sounds could be used to automatically distinguish between hard- and soft-bone tissues. Such a capability could be of value in a variety of surgical procedures involving drilling through bone. We acquired sound signals from six bovine tibial bones that were being drilled with a surgical drill. We investigated various classifiers including logistic regression, support vector machine (SVM), random forest (RF), and hidden Markov model. We explored different time and frequency features, and considered two training/testing scenarios: leave-one bone-out (LOBO) and bone-specific (BSP). Moreover, we conducted a survey of practicing surgeons to provide a baseline measure for assessing whether our proposed algorithm could improve the ability of surgeons to identify hard- and soft-bone tissues based on drilling sounds. The average accuracies for LOBO and BSP were 79.1% and 84.3%, respectively. In both scenarios, the feature that resulted in the highest accuracy of classification was wavelet packet transform coefficients. Moreover, RF and SVM produced the highest accuracies for LOBO and BSP, respectively. In the survey, the surgeons were unsure on 29.2% of questions, and had an average accuracy of 51.4% on their judged answers. In conclusion, the drilling in hard and soft bones could be automatically identified with good accuracy based on the drilling sounds. Several of the algorithms tested were generalizable across specimens and their accuracy significantly exceeded surgeons' performance. The significance is that these algorithms can potentially be used to reduce challenges associated with bone-drilling procedures.
Vahid Zakeri, Antony J. Hodgson
IEEE ACM Trans. Audio Speech Lang. Process.2
2018 Real Time RNN Based 3D Ultrasound Scan Adequacy for Developmental Dysplasia of the Hip
Olivia Paserin, Kishore Mulpuri, Anthony Cooper, Antony J. Hodgson, Rafeef Garbi
MICCAI (1)4
2017 A 3D Femoral Head Coverage Metric for Enhanced Reliability in Diagnosing Hip Dysplasia
Niamul Quader, Antony J. Hodgson, Kishore Mulpuri, Anthony Cooper, Rafeef Abugharbieh
MICCAI (1)2
2016 Towards Reliable Automatic Characterization of Neonatal Hip Dysplasia from 3D Ultrasound Images
Niamul Quader, Antony J. Hodgson, Kishore Mulpuri, Anthony Cooper, Rafeef Abugharbieh
MICCAI (1)2
2014 Robust Bone Detection in Ultrasound Using Combined Strain Imaging and Envelope Signal Power Detection
Mohammad Arafat Hussain, Antony J. Hodgson, Rafeef Abugharbieh
MICCAI (1)2
2012 3D Ultrasound-CT Registration in Orthopaedic Trauma Using GMM Registration with Optimized Particle Simulation-Based Data Reduction
Ilker Hacihaliloglu, Anna Brounstein, Pierre Guy, Antony J. Hodgson, Rafeef Abugharbieh
MICCAI (2)4
2011 Towards Real-Time 3D US to CT Bone Image Registration Using Phase and Curvature Feature Based GMM Matching
Anna Brounstein, Ilker Hacihaliloglu, Pierre Guy, Antony J. Hodgson, Rafeef Abugharbieh
MICCAI (1)4
2008 Bone Segmentation and Fracture Detection in Ultrasound Using 3D Local Phase Features
Ilker Hacihaliloglu, Rafeef Abugharbieh, Antony J. Hodgson, Robert Rohling
MICCAI (1)3
2005 Safety and Accuracy Considerations in Developing a Small Sterilizable Robot for Orthopaedic Surgery
abstract
The objective of this work was to design a compact, accurate, safe, and ease-to-use surgical robot for total knee arthroplasty. The goal of the bone-mounted robot, named Praxiteles, is to precisely position a surgical bone-cutting guide in the appropriate planes surrounding the knee, so that the surgeon can perform the cuts manually using the guide. The robot architecture is comprised of 2 motorized degrees of freedom (DOF) whose axes of rotation are arranged in parallel, and are precisely aligned to the implant cutting planes with a 2 DOF serial adjustment mechanism. An initial prototype was first developed and tested on saw bones and cadavers, and construction of a new, refined version is now well underway. A backdrivable system, with high-stiffness, high-precision static positioning capabilities and safe low-force dynamic movement is achieved using a quick-release, spring-loaded mechanical braking system integrated in a gear transmission unit at the level of the motor outputs. This paper discusses the technical challenges encountered during the development, design, and construction of the system.
Christopher Plaskos, Philippe Cinquin, Antony J. Hodgson, Stéphane Lavallée
ICRA3
2004 Simulating Cheap Hardware: a Platform for Evaluating Cost-performance Trade-offs in Haptic Hardware Design
abstract
This work describes a platform devised to explore the impact on task execution in a virtual environment of the quality, and therefore cost, of the system's haptic hardware. This platform is a complex haptic interface in which hardware quality can be varied in simulation. Software intercepts the position and force signals between the haptic hardware and the virtual environment software, and alters them to supply the effect of increased friction, cogging, backlash, inertia and/or lower force output. All parameters of the introduced effects can be set independently or in combination and on a continuous scale; a primary contribution is the creation of haptically realistic effect models that are stable in combination on complex hardware. This work is part of a larger project in which we test the effect of the simulated degradations on surgeons performance in simulated laparoscopic tasks.
Iman Brouwer, Karon E. MacLean, Antony J. Hodgson
ICRA3
2003 Modelling and Optimization of Bone-Cutting Forces in Orthopaedic Surgery
Christopher Plaskos, Antony J. Hodgson, Philippe Cinquin
MICCAI (1)2
2001 Accurate Femoral Canal Shaping in Total Hip Arthroplasty using a Mini-Robot
abstract
We propose a greatly simplified femoral canal shaping method for robot-assisted total hip replacement surgery that requires neither CT/MRI imaging nor insertion of fiducial markers before surgery. A reamer-shaped registration gauge is inserted into the femoral canal and used to position a base for a robot that is mounted on the top of the femur and used to prepare the femoral canal. In a study using 5 fresh cadavers, the average registration error for selected points near the surface of the femoral cavity was 0.59 mm; this is comparable to the errors reported for the geometry-based registration methods.
Yong-San Yoon, Jung-Ju Lee, Dong-Soo Kwon, J. H. Won, Antony J. Hodgson, Thomas Oxland
ICRA5
2001 Repeatability and Accuracy of Ankle Centre Location Estimates Using a Biaxial Joint Model
Cameron A. Shute, Antony J. Hodgson
MICCAI2
2000 Repeatability and Accuracy of Bone Cutting and Ankle Digitization in Computer-Assisted Total Knee Replacements
Kevin B. Inkpen, Antony J. Hodgson, Christopher Plaskos, Cameron A. Shute, Robert W. McGraw
MICCAI2
2000 A model-independent definition of attractor behavior applicable to interactive tasks
abstract
Both in designing teleoperators or haptic interfaces and in fundamental biological motor control studies, it is important to characterize the motor commands and mechanical impedance responses of the operator (or subject). Although such a characterization is fundamentally impossible for isolated movements when these two aspects of motor behavior have similar time scales (as is the case with humans), it is nonetheless possible, if we are dealing with repeated movements, to measure a trajectory which is analogous to the current source in Norton-equivalent electrical circuits. We define the attractor trajectory to be this equivalent source and show that it rigorously embodies the notion of the attractor point of a time-evolving system. We demonstrate that most previous attempts to test a controversial motor control hypothesis known as the "equilibrium point" or "virtual trajectory" hypothesis are based on inadequate models of the neuromuscular system, and we propose a model-independent means of testing the hypothesis based on a comparison of measurable attractor trajectories at different levels of the motor system. We present and demonstrate means of making such measurements experimentally and of assigning error bounds to the estimated trajectories.
Antony J. Hodgson, Neville Hogan
IEEE Trans. Syst. Man Cybern. Part C1
1999 Accuracy and Repeatability of Joint Centre Location in Computer-Assisted Knee Surgery
Kevin B. Inkpen, Antony J. Hodgson
MICCAI2
1999 The effects of physical constraints in laparoscopic surgery
Antony J. Hodgson, John G. Person, Tim Salcudean, Alex G. Nagy
Medical Image Anal.1
1998 Probe Design to Robustly Locate Anatomical Features
Kevin B. Inkpen, Richard J. Emrich, Antony J. Hodgson
MICCAI3