Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Horst K. Hahn

dblp:87/4973 · also Horst Karl Hahn · DBLP profile ↗
← Back
17ranked-venue papers
4as first author
0since 2021 · last 2019
0000-0001-7512-5762ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Graphics, computer vision, multimedia, augmented reality and games · 14 · 3 first-authorApplied, interdisciplinary, general and emerging computing · 7 · 3 first-authorArtificial intelligence and machine learning · 1Human-computer interaction and ubiquitous computing · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer graphics and multimedia
1 paper
Visualization and visual analytics · 50% Rendering · 50%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Visualization and visual analytics
medical visualization
0.112011
GPU-based Real-Time Approximation of the Ablation Zone for Radiofrequency Ablation · IEEE Trans. Vis. Comput. Graph. 2011
Rendering
volume rendering
0.112011
GPU-based Real-Time Approximation of the Ablation Zone for Radiofrequency Ablation · IEEE Trans. Vis. Comput. Graph. 2011
Medical and health informatics › clinical decision-making
treatment planning
0.012011
GPU-based Real-Time Approximation of the Ablation Zone for Radiofrequency Ablation · IEEE Trans. Vis. Comput. Graph. 2011

Methods — techniques the papers use, named apart from their topics

weighted distance fields · 0.2thermal equilibrium modeling · 0.2shader framework · 0.2
YearPublicationVenuePosition
2019 Uncertainty-aware visual analysis of radiofrequency ablation simulations
Gordan Ristovski, Nicole Garbers, Horst K. Hahn, Tobias Preußer, Lars Linsen
Comput. Graph.3
2017 Uncertainty visualization for interactive assessment of stenotic regions in vascular structures
Gordan Ristovski, José Matute, Thomas Wehrum, Andreas Harloff, Horst K. Hahn, Lars Linsen
Comput. Graph.5
2014 Uncertainty estimation and visualization in probabilistic segmentation
Ahmed Al-Taie, Horst K. Hahn, Lars Linsen
Comput. Graph.2
2014 Uncertainty in medical visualization: Towards a taxonomy
Gordan Ristovski, Tobias Preußer, Horst K. Hahn, Lars Linsen
Comput. Graph.3
2014 Segmentation-Based Partial Volume Correction for Volume Estimation of Solid Lesions in CT
abstract
In oncological chemotherapy monitoring, the change of a tumor's size is an important criterion for assessing cancer therapeutics. Measuring the volume of a tumor requires its delineation in 3-D. This is called segmentation, which is an intensively studied problem in medical image processing. However, simply counting the voxels within a binary segmentation result can lead to significant differences in the volume, if the lesion has been segmented slightly differently by various segmentation procedures or in different scans, for example due to the limited spatial resolution of computed tomography (CT) or partial volume effects. This variability limits the sensitivity of size measurements and thus of therapy response assessments and it can even lead to misclassifications. We present a fast, generic algorithm for measuring the volume of solid, compact tumors in CT that considers partial volume effects at the border of a given segmentation result. The algorithm is an extension of the segmentation-based partial volume analysis proposed by Kuhnigk for the volumetry of solid lung lesions , such that it can be applied to inhomogeneous lesions and lesions with inhomogeneous surroundings. Our generalized segmentation-based partial volume correction is based on a spatial subdivision of the segmentation result, from which the fraction of tumor for each voxel is computed. It has been evaluated on phantom data, 1516 lesion segmentation pairs (lung nodules, liver metastases and lymph nodes) as well as 1851 lung nodules from the LIDC-IDRI database. The evaluations of our algorithm show a more accurate estimation of the real volume and its ability to reduce inter- and intra-observer variability significantly for each entity. Overall, the variability (interquartile range) for phantom data is reduced by 49% ( p ≪ 0.001) and the variability between different readers is reduced by 28% ( p ≪ 0.001). The average computation time is 0.2 s.
Frank Heckel, Hans Meine, Jan Hendrik Moltz, Jan-Martin Kuhnigk, Johannes T. Heverhagen, Andreas Kießling 0002, Boris Buerke, Horst K. Hahn
IEEE Trans. Medical Imaging8
2013 Sketch-Based Editing Tools for Tumour Segmentation in 3D Medical Images
abstract
Abstract In the past years sophisticated automatic segmentation algorithms for various medical image segmentation problems have been developed. However, there are always cases where automatic algorithms fail to provide an acceptable segmentation. In these cases the user needs efficient segmentation editing tools, a problem which has not received much attention in research. We give a comprehensive overview on segmentation editing for three‐dimensional (3D) medical images. For segmentation editing in two‐dimensional (2D) images, we discuss a sketch‐based approach where the user modifies the segmentation in the contour domain. Based on this 2D interface, we present an image‐based as well as an image‐independent method for intuitive and efficient segmentation editing in 3D in the context of tumour segmentation in computed tomography (CT). Our editing tools have been evaluated on a database containing 1226 representative liver metastases, lung nodules and lymph nodes of different shape, size and image quality. In addition, we have performed a qualitative evaluation with radiologists and technical experts, proving the efficiency of our tools.
Frank Heckel, Jan Hendrik Moltz, Christian Tietjen, Horst K. Hahn
Comput. Graph. Forum4
2011 Interactive 3D medical image segmentation with energy-minimizing implicit functions
Frank Heckel, Olaf Konrad, Horst K. Hahn, Heinz-Otto Peitgen
Comput. Graph.3
2011 A Shader Framework for Rapid Prototyping of GPU-Based Volume Rendering
abstract
Abstract In this paper, we present a rapid prototyping framework for GPU‐based volume rendering. Therefore, we propose a dynamic shader pipeline based on the SuperShader concept and illustrate the design decisions. Also, important requirements for the development of our system are presented. In our approach, we break down the rendering shader into areas containing code for different computations, which are defined as freely combinable, modularized shader blocks. Hence, high‐level changes of the rendering configuration result in the implicit modification of the underlying shader pipeline. Furthermore, the prototyping system allows inserting custom shader code between shader blocks of the pipeline at run‐time. A suitable user interface is available within the prototyping environment to allow intuitive modification of the shader pipeline. Thus, appropriate solutions for visualization problems can be interactively developed. We demonstrate the usage and the usefulness of our framework with implementations of dynamic rendering effects for medical applications.
Christian Rieder, Stephan Palmer, Florian Link, Horst K. Hahn
Comput. Graph. Forum4
2011 GPU-based Real-Time Approximation of the Ablation Zone for Radiofrequency Ablation
abstract
Percutaneous radiofrequency ablation (RFA) is becoming a standard minimally invasive clinical procedure for the treatment of liver tumors. However, planning the applicator placement such that the malignant tissue is completely destroyed, is a demanding task that requires considerable experience. In this work, we present a fast GPU-based real-time approximation of the ablation zone incorporating the cooling effect of liver vessels. Weighted distance fields of varying RF applicator types are derived from complex numerical simulations to allow a fast estimation of the ablation zone. Furthermore, the heat-sink effect of the cooling blood flow close to the applicator's electrode is estimated by means of a preprocessed thermal equilibrium representation of the liver parenchyma and blood vessels. Utilizing the graphics card, the weighted distance field incorporating the cooling blood flow is calculated using a modular shader framework, which facilitates the real-time visualization of the ablation zone in projected slice views and in volume rendering. The proposed methods are integrated in our software assistant prototype for planning RFA therapy. The software allows the physician to interactively place virtual RF applicator models. The real-time visualization of the corresponding approximated ablation zone facilitates interactive evaluation of the tumor coverage in order to optimize the applicator's placement such that all cancer cells are destroyed by the ablation.
Christian Rieder, Tim Kröger, Christian Schumann, Horst K. Hahn
IEEE Trans. Vis. Comput. Graph.4
2010 A Fast and Robust Graph-Based Approach for Boundary Estimation of Fiber Bundles Relying on Fractional Anisotropy Maps
abstract
In this paper, a fast and robust graph-based approach for boundary estimation of fiber bundles derived from Diffusion Tensor Imaging (DTI) is presented. DTI is a non-invasive imaging technique that allows the estimation of the location of white matter tracts based on measurements of water diffusion properties. Depending on DTI data, the fiber bundle boundary can be determined to gain information about eloquent structures, which is of major interest for neurosurgery. DTI in combination with tracking algorithms allows the estimation of position and course of fiber tracts in the human brain. The presented method uses these tracking results as the starting point for a graph-based approach. The overall method starts by computing the fiber bundle centerline between two user-defined regions of interests (ROIs). This centerline determines the planes that are used for creating a directed graph. Then, the mincut of the graph is calculated, creating an optimal boundary of the fiber bundle.
Miriam H. A. Bopp, Jan Egger, Tom O'Donnell, Sebastiano Barbieri, Jan Klein 0001, Bernd Freisleben, Horst K. Hahn, Christopher Nimsky
ICPR7
2010 A fast and robust hepatocyte quantification algorithm including vein processing
abstract
BACKGROUND: Quantification of different types of cells is often needed for analysis of histological images. In our project, we compute the relative number of proliferating hepatocytes for the evaluation of the regeneration process after partial hepatectomy in normal rat livers. RESULTS: Our presented automatic approach for hepatocyte (HC) quantification is suitable for the analysis of an entire digitized histological section given in form of a series of images. It is the main part of an automatic hepatocyte quantification tool that allows for the computation of the ratio between the number of proliferating HC-nuclei and the total number of all HC-nuclei for a series of images in one processing run. The processing pipeline allows us to obtain desired and valuable results for a wide range of images with different properties without additional parameter adjustment. Comparing the obtained segmentation results with a manually retrieved segmentation mask which is considered to be the ground truth, we achieve results with sensitivity above 90% and false positive fraction below 15%. CONCLUSIONS: The proposed automatic procedure gives results with high sensitivity and low false positive fraction and can be applied to process entire stained sections.
Tetyana Ivanovska, Andrea Schenk, André Homeyer, Meihong Deng, Uta Dahmen, Olaf Dirsch, Horst K. Hahn, Lars Linsen
BMC Bioinform.7
2004 How Accurate Is Brain Volumetry? A Methodological Evaluation
Horst K. Hahn, Benoît Jolly, Miriam Lee, Daniel Krastel, Jan Rexilius, Johann Drexl, Mathias Schlüter, Burckhard Terwey, Heinz-Otto Peitgen
MICCAI (1)1
2004 A Framework for the Generation of Realistic Brain Tumor Phantoms and Applications
Jan Rexilius, Horst K. Hahn, Mathias Schlüter, Sven Kohle, Holger Bourquain, Joachim Böttcher, Heinz-Otto Peitgen
MICCAI (2)2
2003 Ground Truth in MS Lesion Volumetry - A Phantom Study
Jan Rexilius, Horst K. Hahn, Holger Bourquain, Heinz-Otto Peitgen
MICCAI (2)2
2001 Clinical MRI Based Volumetry: The Cerebral Ventricles
Horst K. Hahn, Markus G. Lentschig, Burckhard Terwey, Heinz-Otto Peitgen
MICCAI1
2001 Visualization and Interaction Techniques for the Exploration of Vascular Structures
abstract
We describe a pipeline of image processing steps for deriving symbolic models of vascular structures from radiological data which reflect the branching pattern and diameter of vessels. For the visualization of these symbolic models, concatenated truncated cones are smoothly blended at branching points. We put emphasis on the quality of the visualizations which is achieved by anti-aliasing operations in different stages of the visualization. The methods presented are referred to as HQVV (high quality vessel visualization). Scalable techniques are provided to explore vascular structures of different orders of magnitude. The hierarchy as well as the diameter of the branches of vascular systems are used to restrict visualizations to relevant subtrees and to emphasize parts of vascular systems. Our research is inspired by clear visualizations in textbooks and is targeted toward medical education and therapy planning. We describe the application of vessel visualization techniques for liver surgery planning. For this application it is crucial to recognize the morphology and branching pattern of vascular systems as well as the basic spatial relations between vessels and other anatomic structures.
Horst K. Hahn, Bernhard Preim, Dirk Selle, Heinz-Otto Peitgen
IEEE Visualization1
2000 The Skull Stripping Problem in MRI Solved by a Single 3D Watershed Transform
Horst K. Hahn, Heinz-Otto Peitgen
MICCAI1