Demo Data from EDBT 2026 / reviewers in the wild / expert
Aaron D. Ward
dblp:88/5058
· DBLP profile ↗
17ranked-venue papers
2as first author
0since 2021 · last 2017
0009-0006-5064-9926ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 15 · 1 first-authorGraphics, computer vision, multimedia, augmented reality and games · 9 · 1 first-authorArtificial intelligence and machine learning · 2 · 1 first-author
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Computer graphics and multimedia
1 paper |
Geometric modeling and processing · 100% | |
| Artificial intelligence
1 paper |
Segmentation and scene understanding · 100% | |
| Databases, data mining, and information retrieval
1 paper |
Information retrieval · 100% |
Topics — the 5 heaviest of 6, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Computer vision › Segmentation and scene understanding
image segmentation |
0.1 | 1 | 2012 | Segmentation with Non-linear Regional Constraints via Line-Search Cuts · ECCV (1) 2012 |
Geometric modeling and processing › skeletonization
medial axis transform |
0.1 | 1 | 2010 | The Groupwise Medial Axis Transform for Fuzzy Skeletonization and Pruning · IEEE Trans. Pattern Anal. Mach. Intell. 2010 |
Geometric modeling and processing
shape analysis |
0.1 | 1 | 2010 | The Groupwise Medial Axis Transform for Fuzzy Skeletonization and Pruning · IEEE Trans. Pattern Anal. Mach. Intell. 2010 |
Geometric modeling and processing
skeletonization |
0.1 | 1 | 2010 | The Groupwise Medial Axis Transform for Fuzzy Skeletonization and Pruning · IEEE Trans. Pattern Anal. Mach. Intell. 2010 |
Information retrieval › image retrieval
object retrieval |
0.0 | 1 | 2010 | The Groupwise Medial Axis Transform for Fuzzy Skeletonization and Pruning · IEEE Trans. Pattern Anal. Mach. Intell. 2010 |
Methods — techniques the papers use, named apart from their topics
skeleton pruning · 0.2groupwise medial axis transform · 0.2branch significance measure · 0.2non-linear constraints · 0.1line-search cuts · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2017 | Robust 2-D-3-D Registration Optimization for Motion Compensation During 3-D TRUS-Guided Biopsy Using Learned Prostate Motion DataabstractIn magnetic resonance (MR)-targeted, 3-D transrectal ultrasound (TRUS)-guided biopsy, prostate motion during the procedure increases the needle targeting error and limits the ability to accurately sample MR-suspicious tumor volumes. The robustness of the 2-D-3-D registration methods for prostate motion compensation is impacted by local optima in the search space. In this paper, we analyzed the prostate motion characteristics and investigated methods to incorporate such knowledge into the registration optimization framework to improve robustness against local optima. Rigid motion of the prostate was analyzed adopting a mixture-of-Gaussian (MoG) model using 3-D TRUS images acquired at bilateral sextant probe positions with a mechanically assisted biopsy system. The learned motion characteristics were incorporated into Powell's direction set method by devising multiple initial search positions and initial search directions. Experiments were performed on data sets acquired during clinical biopsy procedures, and registration error was evaluated using target registration error (TRE) and converged image similarity metric values after optimization. After incorporating the learned initialization positions and directions in Powell's method, 2-D-3-D registration to compensate for motion during prostate biopsy was performed with rms ± std TRE of 2.33 ± 1.09 mm with ~3 s mean execution time per registration. This was an improvement over 3.12 ± 1.70 mm observed in Powell's standard approach. For the data acquired under clinical protocols, the converged image similarity metric value improved in ≥8% of the registrations whereas it degraded only ≤1% of the registrations. The reported improvements in optimization indicate useful advancements in robustness to ensure smooth clinical integration of a registration solution for motion compensation that facilitates accurate sampling of the smallest clinically significant tumors. Tharindu De Silva, Derek W. Cool, Jing Yuan 0001, Cesare Romagnoli, Jagath Samarabandu, Aaron Fenster, Aaron D. Ward |
IEEE Trans. Medical Imaging | 7 |
| 2016 | Prostate Cancer: Improved Tissue Characterization by Temporal Modeling of Radio-Frequency Ultrasound Echo Data
Layan Nahlawi, Farhad Imani, Mena Gaed, Jose A. Gomez, Madeleine Moussa, Eli Gibson, Aaron Fenster, Aaron D. Ward, Purang Abolmaesumi, Hagit Shatkay, Parvin Mousavi |
MICCAI (1) | 8 |
| 2015 | Using Hidden Markov Models to capture temporal aspects of ultrasound data in prostate cancerabstractRecent studies highlight temporal ultrasound data as highly promising in differentiating between malignant and benign tissues in prostate cancer patients. Since Hidden Markov Models can be used for capturing order and patterns in time varying signals, we employ them to model temporal aspects of ultrasound data that are typically not incorporated in existing models. By comparing order-preserving and order-altering models, we demonstrate that the order encoded in the series is necessary to model the variability in ultrasound data of prostate tissues. In future studies, we will investigate the influence of order on the differentiation between malignant and benign tissues. Layan Nahlawi, Farhad Imani, Mena Gaed, Jose A. Gomez, Madeleine Moussa, Eli Gibson, Aaron Fenster, Aaron D. Ward, Purang Abolmaesumi, Parvin Mousavi, Hagit Shatkay |
BIBM | 8 |
| 2015 | Computer-Aided Prostate Cancer Detection Using Ultrasound RF Time Series: In Vivo Feasibility StudyabstractUNLABELLED: This paper presents the results of a computer-aided intervention solution to demonstrate the application of RF time series for characterization of prostate cancer, in vivo. METHODS: We pre-process RF time series features extracted from 14 patients using hierarchical clustering to remove possible outliers. Then, we demonstrate that the mean central frequency and wavelet features extracted from a group of patients can be used to build a nonlinear classifier which can be applied successfully to differentiate between cancerous and normal tissue regions of an unseen patient. RESULTS: In a cross-validation strategy, we show an average area under receiver operating characteristic curve (AUC) of 0.93 and classification accuracy of 80%. To validate our results, we present a detailed ultrasound to histology registration framework. CONCLUSION: Ultrasound RF time series results in differentiation of cancerous and normal tissue with high AUC. Farhad Imani, Purang Abolmaesumi, Eli Gibson, Amir Khojaste, Mena Gaed, Madeleine Moussa, Jose A. Gomez, Cesare Romagnoli, Michael Leveridge, Silvia D. Chang, Robert Siemens, Aaron Fenster, Aaron D. Ward, Parvin Mousavi |
IEEE Trans. Medical Imaging | 13 |
| 2015 | Statistical Biomechanical Surface Registration: Application to MR-TRUS Fusion for Prostate InterventionsabstractA common challenge when performing surface-based registration of images is ensuring that the surfaces accurately represent consistent anatomical boundaries. Image segmentation may be difficult in some regions due to either poor contrast, low slice resolution, or tissue ambiguities. To address this, we present a novel non-rigid surface registration method designed to register two partial surfaces, capable of ignoring regions where the anatomical boundary is unclear. Our probabilistic approach incorporates prior geometric information in the form of a statistical shape model (SSM), and physical knowledge in the form of a finite element model (FEM). We validate results in the context of prostate interventions by registering pre-operative magnetic resonance imaging (MRI) to 3D transrectal ultrasound (TRUS). We show that both the geometric and physical priors significantly decrease net target registration error (TRE), leading to TREs of 2.35 ± 0.81 mm and 2.81 ± 0.66 mm when applied to full and partial surfaces, respectively. We investigate robustness in response to errors in segmentation, varying levels of missing data, and adjusting the tunable parameters. Results demonstrate that the proposed surface registration method is an efficient, robust, and effective solution for fusing data from multiple modalities. Siavash Khallaghi, C. Antonio Sánchez, Abtin Rasoulian, Saman Nouranian, Cesare Romagnoli, Hamidreza Abdi, Silvia D. Chang, Peter C. Black, Larry Goldenberg, William J. Morris, Ingrid Spadinger, Aaron Fenster, Aaron D. Ward, Sidney S. Fels, Purang Abolmaesumi |
IEEE Trans. Medical Imaging | 13 |
| 2015 | Biomechanically Constrained Surface Registration: Application to MR-TRUS Fusion for Prostate InterventionsabstractIn surface-based registration for image-guided interventions, the presence of missing data can be a significant issue. This often arises with real-time imaging modalities such as ultrasound, where poor contrast can make tissue boundaries difficult to distinguish from surrounding tissue. Missing data poses two challenges: ambiguity in establishing correspondences; and extrapolation of the deformation field to those missing regions. To address these, we present a novel non-rigid registration method. For establishing correspondences, we use a probabilistic framework based on a Gaussian mixture model (GMM) that treats one surface as a potentially partial observation. To extrapolate and constrain the deformation field, we incorporate biomechanical prior knowledge in the form of a finite element model (FEM). We validate the algorithm, referred to as GMM-FEM, in the context of prostate interventions. Our method leads to a significant reduction in target registration error (TRE) compared to similar state-of-the-art registration algorithms in the case of missing data up to 30%, with a mean TRE of 2.6 mm. The method also performs well when full segmentations are available, leading to TREs that are comparable to or better than other surface-based techniques. We also analyze robustness of our approach, showing that GMM-FEM is a practical and reliable solution for surface-based registration. Siavash Khallaghi, C. Antonio Sánchez, Abtin Rasoulian, Yue Sun 0001, Farhad Imani, Amir Khojaste, Orcun Goksel, Cesare Romagnoli, Hamidreza Abdi, Silvia D. Chang, Parvin Mousavi, Aaron Fenster, Aaron D. Ward, Sidney S. Fels, Purang Abolmaesumi |
IEEE Trans. Medical Imaging | 13 |
| 2013 | Ultrasound-Based Characterization of Prostate Cancer: An in vivo Clinical Feasibility Study
Farhad Imani, Purang Abolmaesumi, Eli Gibson, Amir Khojaste, Mena Gaed, Madeleine Moussa, Jose A. Gomez, Cesare Romagnoli, Robert Siemens, Michael Leveridge, Silvia D. Chang, Aaron Fenster, Aaron D. Ward, Parvin Mousavi |
MICCAI (2) | 13 |
| 2013 | Improving 2D-3D Registration Optimization Using Learned Prostate Motion Data
Tharindu De Silva, Derek W. Cool, Jing Yuan 0001, Cesare Romagnoli, Aaron Fenster, Aaron D. Ward |
MICCAI (2) | 6 |
| 2013 | The impact of registration accuracy on imaging validation study design: A novel statistical power calculation
Eli Gibson, Aaron Fenster, Aaron D. Ward |
Medical Image Anal. | 3 |
| 2013 | Prostate Histopathology: Learning Tissue Component Histograms for Cancer Detection and ClassificationabstractRadical prostatectomy is performed on approximately 40% of men with organ-confined prostate cancer. Pathologic information obtained from the prostatectomy specimen provides important prognostic information and guides recommendations for adjuvant treatment. The current pathology protocol in most centers involves primarily qualitative assessment. In this paper, we describe and evaluate our system for automatic prostate cancer detection and grading on hematoxylin & eosin-stained tissue images. Our approach is intended to address the dual challenges of large data size and the need for high-level tissue information about the locations and grades of tumors. Our system uses two stages of AdaBoost-based classification. The first provides high-level tissue component labeling of a superpixel image partitioning. The second uses the tissue component labeling to provide a classification of cancer versus noncancer, and low-grade versus high-grade cancer. We evaluated our system using 991 sub-images extracted from digital pathology images of 50 whole-mount tissue sections from 15 prostatectomy patients. We measured accuracies of 90% and 85% for the cancer versus noncancer and high-grade versus low-grade classification tasks, respectively. This system represents a first step toward automated cancer quantification on prostate digital histopathology imaging, which could pave the way for more accurately informed postprostatectomy patient care. Lena Gorelick, Olga Veksler, Mena Gaed, Jose A. Gomez, Madeleine Moussa, Glenn Bauman, Aaron Fenster, Aaron D. Ward |
IEEE Trans. Medical Imaging | 8 |
| 2012 | Segmentation with Non-linear Regional Constraints via Line-Search Cuts
Lena Gorelick, Frank R. Schmidt, Yuri Boykov, Andrew Delong, Aaron D. Ward |
ECCV (1) | 5 |
| 2012 | Registration Accuracy: How Good Is Good Enough? A Statistical Power Calculation Incorporating Image Registration Uncertainty
Eli Gibson, Aaron Fenster, Aaron D. Ward |
MICCAI (2) | 3 |
| 2010 | Extraction of the Plane of Minimal Cross-Sectional Area of the Corpus Callosum Using Template-Driven Segmentation
Neda Changizi, Ghassan Hamarneh, Omer Ishaq, Aaron D. Ward, Roger C. Tam |
MICCAI (3) | 4 |
| 2010 | Evaluation of Inter-session 3D-TRUS to 3D-TRUS Image Registration for Repeat Prostate Biopsies
Vaishali V. Karnik, Aaron Fenster, Jeff Bax, Lori Gardi, Igor Gyacskov, Jacques Montreuil, Cesare Romagnoli, Aaron D. Ward |
MICCAI (2) | 8 |
| 2010 | Quantification of Prostate Deformation due to Needle Insertion during TRUS-guided Biopsy
Tharindu De Silva, Aaron Fenster, Jagath Samarabandu, Aaron D. Ward |
MICCAI (3) | 4 |
| 2010 | The Groupwise Medial Axis Transform for Fuzzy Skeletonization and PruningabstractMedial representations of shapes are useful due to their use of an object-centered coordinate system that directly captures intuitive notions of shape such as thickness, bending, and elongation. However, it is well known that an object's medial axis transform (MAT) is unstable with respect to small perturbations of its boundary. This instability results in additional, unwanted branches in the skeletons, which must be pruned in order to recover the portions of the skeletons arising purely from the uncorrupted shape information. Almost all approaches to skeleton pruning compute a significance measure for each branch according to some heuristic criteria, and then prune the least significant branches first. Current approaches to branch significance computation can be classified as either local, solely using information from a neighborhood surrounding each branch, or global, using information about the shape as a whole. In this paper, we propose a third, groupwise approach to branch significance computation. We develop a groupwise skeletonization framework that yields a fuzzy significance measure for each branch, derived from information provided by the group of shapes. We call this framework the Groupwise Medial Axis Transform (G-MAT). We propose and evaluate four groupwise methods for computing branch significance and report superior performance compared to a recent, leading method. We measure the performance of each pruning algorithm using denoising, classification, and within-class skeleton similarity measures. This research has several applications, including object retrieval and shape analysis. Aaron D. Ward, Ghassan Hamarneh |
IEEE Trans. Pattern Anal. Mach. Intell. | 1 |
| 2007 | Statistical Shape Modeling Using MDL Incorporating Shape, Appearance, and Expert Knowledge
Aaron D. Ward, Ghassan Hamarneh |
MICCAI (1) | 1 |