Demo Data from EDBT 2026 / reviewers in the wild / expert
Youhei Omasa
dblp:90/8368
· DBLP profile ↗
1ranked-venue papers
0as first author
0since 2021 · last 2010
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
1 paper |
Haptics and multimodal interaction · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 3 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Haptics and multimodal interaction › haptic interface
force display |
0.1 | 1 | 2010 | Force visualization mechanism using a Moiré fringe applied to endoscopic surgical instruments · ICRA 2010 |
Medical and health informatics › surgical robotics
endoscopic surgery |
0.0 | 1 | 2010 | Force visualization mechanism using a Moiré fringe applied to endoscopic surgical instruments · ICRA 2010 |
Medical and health informatics
surgical robotics |
0.0 | 1 | 2010 | Force visualization mechanism using a Moiré fringe applied to endoscopic surgical instruments · ICRA 2010 |
Methods — techniques the papers use, named apart from their topics
passive force visualization · 0.2moiré fringe · 0.2
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2010 | Force visualization mechanism using a Moiré fringe applied to endoscopic surgical instrumentsabstractThis paper presents a force visualization mechanism for endoscopic surgical instruments using a Moirée fringe. This mechanism can display fringes or characters that correspond to the magnitude of a force between the surgical instruments and internal organs without the use of electronic elements, such as amplifiers and strain gauges. As this mechanism is simply attached to the surgical instruments, there is no need for additional devices in the operating room or wires to connect these devices. The structure is simple, and its fabrication is inexpensive. An example is shown with the mechanism mounted on a 10-mm forceps. We experimentally verified in vivo, using a pig, that it can display characters corresponding to the magnitude of the force, thus visually displaying the force even in endoscopic image. Takeshi Takaki, Youhei Omasa, Idaku Ishii, Tomohiro Kawahara, Masazumi Okajima |
ICRA | 2 |