Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Xiang Zhang 0003

dblp:91/4353-3 · DBLP profile ↗
← Back
15ranked-venue papers
0as first author
0since 2021 · last 2013
0000-0003-1102-6313ORCID · conflict

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 15

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
4 papers
Bioinformatics and computational biology · 94% Computational science and engineering · 6%

Topics — the 8 heaviest of 10, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Bioinformatics and computational biology
metabolomics
0.432013
MetPP: a computational platform for comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry-based metabolomics · Bioinform. 2013
A method of finding optimal weight factors for compound identification in gas chromatography-mass spectrometry · Bioinform. 2012
An optimal peak alignment for comprehensive two-dimensional gas chromatography mass spectrometry using mixture similarity measure · Bioinform. 2011
Bioinformatics and computational biology › metabolomics
peak alignment
0.322013
MetPP: a computational platform for comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry-based metabolomics · Bioinform. 2013
An optimal peak alignment for comprehensive two-dimensional gas chromatography mass spectrometry using mixture similarity measure · Bioinform. 2011
Bioinformatics and computational biology
biomarker discovery
0.212013
MetPP: a computational platform for comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry-based metabolomics · Bioinform. 2013
Bioinformatics and computational biology › molecular informatics › cheminformatics
compound identification
0.112012
A method of finding optimal weight factors for compound identification in gas chromatography-mass spectrometry · Bioinform. 2012
Computational science and engineering
hierarchical model
0.112008
A hierarchical statistical model to assess the confidence of peptides and proteins inferred from tandem mass spectrometry · Bioinform. 2008
Bioinformatics and computational biology › proteomics
peptide and protein identification
0.112008
A hierarchical statistical model to assess the confidence of peptides and proteins inferred from tandem mass spectrometry · Bioinform. 2008
Bioinformatics and computational biology
proteomics
0.112008
A hierarchical statistical model to assess the confidence of peptides and proteins inferred from tandem mass spectrometry · Bioinform. 2008
Bioinformatics and computational biology › proteomics
tandem mass spectrometry
0.012008
A hierarchical statistical model to assess the confidence of peptides and proteins inferred from tandem mass spectrometry · Bioinform. 2008

Methods — techniques the papers use, named apart from their topics

statistical significance testing · 0.2retention index matching · 0.2peak filtering · 0.2pattern recognition · 0.2normalization · 0.2skewness-to-kurtosis ratio optimization · 0.1mixture similarity · 0.1canberra distance · 0.1hierarchical bayesian modeling · 0.1
YearPublicationVenuePosition
2013 MetPP: a computational platform for comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry-based metabolomics
abstract
MOTIVATION: Due to the high complexity of metabolome, the comprehensive 2D gas chromatography time-of-flight mass spectrometry (GC×GC-TOF MS) is considered as a powerful analytical platform for metabolomics study. However, the applications of GC×GC-TOF MS in metabolomics are not popular owing to the lack of bioinformatics system for data analysis. RESULTS: We developed a computational platform entitled metabolomics profiling pipeline (MetPP) for analysis of metabolomics data acquired on a GC×GC-TOF MS system. MetPP can process peak filtering and merging, retention index matching, peak list alignment, normalization, statistical significance tests and pattern recognition, using the peak lists deconvoluted from the instrument data as its input. The performance of MetPP software was tested with two sets of experimental data acquired in a spike-in experiment and a biomarker discovery experiment, respectively. MetPP not only correctly aligned the spiked-in metabolite standards from the experimental data, but also correctly recognized their concentration difference between sample groups. For analysis of the biomarker discovery data, 15 metabolites were recognized with significant concentration difference between the sample groups and these results agree with the literature results of histological analysis, demonstrating the effectiveness of applying MetPP software for disease biomarker discovery. AVAILABILITY: The source code of MetPP is available at http://metaopen.sourceforge.net CONTACT: [email protected] SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Xiaoli Wei, Xue Shi, Imhoi Koo, Robin H. Schmidt, Gavin E. Arteel, Walter H. Watson, Craig McClain, Xiang Zhang 0003
Bioinform.9
2013 An efficient post-hoc integration method improving peak alignment of metabolomics data from GCxGC/TOF-MS
abstract
BACKGROUND: Since peak alignment in metabolomics has a huge effect on the subsequent statistical analysis, it is considered a key preprocessing step and many peak alignment methods have been developed. However, existing peak alignment methods do not produce satisfactory results. Indeed, the lack of accuracy results from the fact that peak alignment is done separately from another preprocessing step such as identification. Therefore, a post-hoc approach, which integrates both identification and alignment results, is in urgent need for the purpose of increasing the accuracy of peak alignment. RESULTS: The proposed post-hoc method was validated with three datasets such as a mixture of compound standards, metabolite extract from mouse liver, and metabolite extract from wheat. Compared to the existing methods, the proposed approach improved peak alignment in terms of various performance measures. Also, post-hoc approach was verified to improve peak alignment by manual inspection. CONCLUSIONS: The proposed approach, which combines the information of metabolite identification and alignment, clearly improves the accuracy of peak alignment in terms of several performance measures. R package and examples using a dataset are available at http://mrr.sourceforge.net/download.html.
Jaesik Jeong, Xiang Zhang 0003, Xue Shi, Changyu Shen
BMC Bioinform.2
2012 Reconstruction of Metabolic Association Networks Using High-throughput Mass Spectrometry Data
Imhoi Koo, Xiang Zhang 0003
ICIC (1)2
2012 A Novel Two-Stage Alignment Method for Liquid Chromatography Mass Spectrometry-Based Metabolomics
Xiaoli Wei, Xue Shi, Craig McClain, Xiang Zhang 0003
ICIC (1)5
2012 A method of finding optimal weight factors for compound identification in gas chromatography-mass spectrometry
abstract
MOTIVATION: The compound identification in gas chromatography-mass spectrometry (GC-MS) is achieved by matching the experimental mass spectrum to the mass spectra in a spectral library. It is known that the intensities with higher m/z value in the GC-MS mass spectrum are the most diagnostic. Therefore, to increase the relative significance of peak intensities of higher m/z value, the intensities and m/z values are usually transformed with a set of weight factors. A poor quality of weight factors can significantly decrease the accuracy of compound identification. With the significant enrichment of the mass spectral database and the broad application of GC-MS, it is important to re-visit the methods of discovering the optimal weight factors for high confident compound identification. RESULTS: We developed a novel approach to finding the optimal weight factors only through a reference library for high accuracy compound identification. The developed approach first calculates the ratio of skewness to kurtosis of the mass spectral similarity scores among spectra (compounds) in a reference library and then considers a weight factor with the maximum ratio as the optimal weight factor. We examined our approach by comparing the accuracy of compound identification using the mass spectral library maintained by the National Institute of Standards and Technology. The results demonstrate that the optimal weight factors for fragment ion peak intensity and m/z value found by the developed approach outperform the current weight factors for compound identification. AVAILABILITY: The results and R package are available at http://stage.louisville.edu/faculty/x0zhan17/software/ software-development.
Imhoi Koo, Xiaoli Wei, Xiang Zhang 0003
Bioinform.4
2012 Model-based peak alignment of metabolomic profiling from comprehensive two-dimensional gas chromatography mass spectrometry
abstract
BACKGROUND: Comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC/TOF-MS) has been used for metabolite profiling in metabolomics. However, there is still much experimental variation to be controlled including both within-experiment and between-experiment variation. For efficient analysis, an ideal peak alignment method to deal with such variations is in great need. RESULTS: Using experimental data of a mixture of metabolite standards, we demonstrated that our method has better performance than other existing method which is not model-based. We then applied our method to the data generated from the plasma of a rat, which also demonstrates good performance of our model. CONCLUSIONS: We developed a model-based peak alignment method to process both homogeneous and heterogeneous experimental data. The unique feature of our method is the only model-based peak alignment method coupled with metabolite identification in an unified framework. Through the comparison with other existing method, we demonstrated that our method has better performance. Data are available at http://stage.louisville.edu/faculty/x0zhan17/software/software-development/mspa. The R source codes are available at http://www.biostat.iupui.edu/~ChangyuShen/CodesPeakAlignment.zip. TRIAL REGISTRATION: 2136949528613691.
Jaesik Jeong, Xue Shi, Xiang Zhang 0003, Changyu Shen
BMC Bioinform.3
2011 DISCO2: A Comprehensive Peak Alignment Algorithm for Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry
Bing Wang 0004, Aiqin Fang, Xue Shi, Xiang Zhang 0003
ICIC (3)5
2011 An optimal peak alignment for comprehensive two-dimensional gas chromatography mass spectrometry using mixture similarity measure
abstract
MOTIVATION: Comprehensive two-dimensional gas chromatography mass spectrometry (GC × GC-MS) brings much increased separation capacity, chemical selectivity and sensitivity for metabolomics and provides more accurate information about metabolite retention times and mass spectra. However, there is always a shift of retention times in the two columns that makes it difficult to compare metabolic profiles obtained from multiple samples exposed to different experimental conditions. RESULTS: The existing peak alignment algorithms for GC × GC-MS data use the peak distance and the spectra similarity sequentially and require predefined either distance-based window and/or spectral similarity-based window. To overcome the limitations of the current alignment methods, we developed an optimal peak alignment using a novel mixture similarity by employing the peak distance and the spectral similarity measures simultaneously without any variation windows. In addition, we examined the effect of the four different distance measures such as Euclidean, Maximum, Manhattan and Canberra distances on the peak alignment. The performance of our proposed peak alignment algorithm was compared with the existing alignment methods on the two sets of GC × GC-MS data. Our analysis showed that Canberra distance performed better than other distances and the proposed mixture similarity peak alignment algorithm prevailed against all literature reported methods. AVAILABILITY: The data and software mSPA are available at http://stage.louisville.edu/faculty/x0zhan17/software/software-development.
Aiqin Fang, Bing Wang 0004, Jaesik Jeong, Xiang Zhang 0003
Bioinform.5
2011 An empirical Bayes model using a competition score for metabolite identification in gas chromatography mass spectrometry
abstract
BACKGROUND: Mass spectrometry (MS) based metabolite profiling has been increasingly popular for scientific and biomedical studies, primarily due to recent technological development such as comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC/TOF-MS). Nevertheless, the identifications of metabolites from complex samples are subject to errors. Statistical/computational approaches to improve the accuracy of the identifications and false positive estimate are in great need. We propose an empirical Bayes model which accounts for a competing score in addition to the similarity score to tackle this problem. The competition score characterizes the propensity of a candidate metabolite of being matched to some spectrum based on the metabolite's similarity score with other spectra in the library searched against. The competition score allows the model to properly assess the evidence on the presence/absence status of a metabolite based on whether or not the metabolite is matched to some sample spectrum. RESULTS: With a mixture of metabolite standards, we demonstrated that our method has better identification accuracy than other four existing methods. Moreover, our method has reliable false discovery rate estimate. We also applied our method to the data collected from the plasma of a rat and identified some metabolites from the plasma under the control of false discovery rate. CONCLUSIONS: We developed an empirical Bayes model for metabolite identification and validated the method through a mixture of metabolite standards and rat plasma. The results show that our hierarchical model improves identification accuracy as compared with methods that do not structurally model the involved variables. The improvement in identification accuracy is likely to facilitate downstream analysis such as peak alignment and biomarker identification. Raw data and result matrices can be found at http://www.biostat.iupui.edu/~ChangyuShen/index.htm. TRIAL REGISTRATION: 2123938128573429.
Jaesik Jeong, Xue Shi, Xiang Zhang 0003, Changyu Shen
BMC Bioinform.3
2011 Smith-Waterman Peak Alignment for Comprehensive Two-dimensional Gas Chromatography Mass Spectrometry
abstract
BACKGROUND: Comprehensive two-dimensional gas chromatography coupled with mass spectrometry (GC × GC-MS) is a powerful technique which has gained increasing attention over the last two decades. The GC × GC-MS provides much increased separation capacity, chemical selectivity and sensitivity for complex sample analysis and brings more accurate information about compound retention times and mass spectra. Despite these advantages, the retention times of the resolved peaks on the two-dimensional gas chromatographic columns are always shifted due to experimental variations, introducing difficulty in the data processing for metabolomics analysis. Therefore, the retention time variation must be adjusted in order to compare multiple metabolic profiles obtained from different conditions. RESULTS: We developed novel peak alignment algorithms for both homogeneous (acquired under the identical experimental conditions) and heterogeneous (acquired under the different experimental conditions) GC × GC-MS data using modified Smith-Waterman local alignment algorithms along with mass spectral similarity. Compared with literature reported algorithms, the proposed algorithms eliminated the detection of landmark peaks and the usage of retention time transformation. Furthermore, an automated peak alignment software package was established by implementing a likelihood function for optimal peak alignment. CONCLUSIONS: The proposed Smith-Waterman local alignment-based algorithms are capable of aligning both the homogeneous and heterogeneous data of multiple GC × GC-MS experiments without the transformation of retention times and the selection of landmark peaks. An optimal version of the SW-based algorithms was also established based on the associated likelihood function for the automatic peak alignment. The proposed alignment algorithms outperform the literature reported alignment method by analyzing the experiment data of a mixture of compound standards and a metabolite extract of mouse plasma with spiked-in compound standards.
Imhoi Koo, Aiqin Fang, Xiang Zhang 0003
BMC Bioinform.4
2010 Optimal Selection of Support Vector Regression Parameters and Molecular Descriptors for Retention Indices Prediction
Jun Zhang 0011, Bing Wang 0004, Xiang Zhang 0003
ICIC (2)3
2010 Statistical analysis of multiple significance test methods for differential proteomics
abstract
In current proteomics research, a big challenge is to differentiate the correlative proteins for a given biological function from all existing proteins, and if it does, how strong is the relationship between the proteins and function. Statistical significance testing can be used to address this question. However, every traditional statistical test method may suffer from the inability to identify important differentially expressed proteins if the biological samples do not completely meet the assumptions of each test method [ 1 ]. To detect the regulated proteins for differential proteomics, we analyze multiple significance test methods and discover some significance proteins. We use the four statistical methods, i.e., Kolmogorov-Smirnov test (KS-test), Baumgartner-Weib-Schindler test (BWS-test), T-test, Brunner-Munzel test (BM-test) to measure the difference of the expression level of individual protein under two experimental conditions, respectively. The results had been successfully used for the discovery of protein biomarkers in breast cancer.
Bing Wang 0004, Fahim Mohammad, Jun Zhang 0011, Xinmin Yin, Eric C. Rouchka, Xiang Zhang 0003
BMC Bioinform.6
2010 Artificial neural networks for the prediction of peptide drift time in ion mobility mass spectrometry
abstract
BACKGROUND: There is an increasing usage of ion mobility-mass spectrometry (IMMS) in proteomics. IMMS combines the features of ion mobility spectrometry (IMS) and mass spectrometry (MS). It separates and detects peptide ions on a millisecond time-scale. IMS separates peptide ions based on drift time that is determined by the collision cross-section of each peptide ion in a given experiment condition. A peptide ion's collision cross-section is related to the ion size and shape resulted from the peptide amino acid sequence and their modifications. This inherent relation between the drift time of peptide ion and peptide sequence indicates that the drift time of peptide ions can be used to infer peptide sequence and therefore, for peptide identification. RESULTS: This paper describes an artificial neural networks (ANNs) regression model for the prediction of peptide ion drift time in IMMS. Each peptide in this work was represented using three descriptors (i.e., molecular weight, sequence length and a two-dimensional sequence index). An ANN predictor consisting of four input nodes, three hidden nodes and one output node was constructed for peptide ion drift time prediction. For the model training and testing, a 10-fold cross-validation strategy was employed for three datasets each containing different charge states. Dataset one contains 212 singly-charged peptide ions, dataset two has 306 doubly-charged peptide ions, and dataset three has 77 triply-charged peptide ions. Our proposed method achieved 94.4%, 93.6% and 74.2% prediction accuracy for singly-, doubly- and triply-charged peptide ions, respectively. CONCLUSIONS: An ANN-based method has been developed for predicting the drift time of peptide ions in IMMS. The results achieved here demonstrate the effectiveness and efficiency of the prediction model. This work can enhance the confidence of protein identification by combining with current database search approaches for protein identification.
Bing Wang 0004, Steve Valentine, Manolo Plasencia, Sriram Raghuraman, Xiang Zhang 0003
BMC Bioinform.5
2009 Prediction of peptide drift time in ion mobility-mass spectrometry
Bing Wang 0004, Steve Valentine, Sriram Raghuraman, Manolo Plasencia, Xiang Zhang 0003
BMC Bioinform.5
2008 A hierarchical statistical model to assess the confidence of peptides and proteins inferred from tandem mass spectrometry
abstract
MOTIVATION: Statistical evaluation of the confidence of peptide and protein identifications made by tandem mass spectrometry is a critical component for appropriately interpreting the experimental data and conducting downstream analysis. Although many approaches have been developed to assign confidence measure from different perspectives, a unified statistical framework that integrates the uncertainty of peptides and proteins is still missing. RESULTS: We developed a hierarchical statistical model (HSM) that jointly models the uncertainty of the identified peptides and proteins and can be applied to any scoring system. With data sets of a standard mixture and the yeast proteome, we demonstrate that the HSM offers a reliable or at least conservative false discovery rate (FDR) estimate for peptide and protein identifications. The probability measure of HSM also offers a powerful discriminating score for peptide identification. AVAILABILITY: The algorithm is available upon request from the authors.
Changyu Shen, Ganesh Shankar, Xiang Zhang 0003, Lang Li 0001
Bioinform.4