Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Ali H. Shoeb

dblp:94/7124 · DBLP profile ↗
← Back
4ranked-venue papers
2as first author
0since 2021 · last 2012
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 2 · 2 first-authorComputer networks · 1Graphics, computer vision, multimedia, augmented reality and games · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
1 paper
Wearable and physiological sensing · 81% Health and well-being technologies · 19%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 2 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › EEG analysis
seizure detection
0.112010
Application of Machine Learning To Epileptic Seizure Detection · ICML 2010
Wearable and physiological sensing
sensor selection
0.012009
Sensor selection for energy-efficient ambulatory medical monitoring · MobiSys 2009

Methods — techniques the papers use, named apart from their topics

machine learning · 0.1energy-efficient sensing · 0.1
YearPublicationVenuePosition
2012 Enabling system-level platform resilience through embedded data-driven inference capabilities in electronic devices
abstract
Advanced devices for embedded and ambient applications represent one of the most compelling classes of electronic systems, but they also impose more severe constraints on system resources than ever before. Although platform non-idealities have always posed a fundamental limitation, the overheads of conventional margining are now reaching intolerable levels. We describe an alternate approach to hardware resilience that applies to applications where advanced modeling and inference capabilities are required, a rapidly increasing emphasis in many applications. We show how a data-driven modeling framework for analyzing application data can also be used to effectively model and overcome a broad range of hardware non-idealities. Specific examples for biomedical sensors are shown that are able to retain performance with minimal on-line overhead despite the presence of severe digital- and analog-circuit non-idealities.
Naveen Verma, Kyong-Ho Lee, Kuk Jin Jang, Ali H. Shoeb
ICASSP4
2010 Application of Machine Learning To Epileptic Seizure Detection
Ali H. Shoeb, John V. Guttag
ICML1
2009 Sensor selection for energy-efficient ambulatory medical monitoring
abstract
Epilepsy affects over three million Americans of all ages. Despite recent advances, more than 20% of individuals with epilepsy never achieve adequate control of their seizures. The use of a small, portable, non-invasive seizure monitor could benefit these individuals tremendously. However, in order for such a device to be suitable for long-term wear, it must be both comfortable and lightweight.
Eugene Shih, Ali H. Shoeb, John V. Guttag
MobiSys2
2009 Non-Invasive Computerized System for Automatically Initiating Vagus Nerve Stimulation Following Patient-Specific Detection of Seizures or epileptiform discharges
abstract
OBJECTIVE: To demonstrate the feasibility of using a computerized system to detect the onset of a seizure and, in response, initiate Vagus nerve stimulation (VNS) in patients with medically refractory epilepsy. METHODS: We designed and built a non-invasive, computerized system that automatically initiates VNS following the real-time detection of a pre-identified seizure or epileptiform discharge. The system detects these events through patient-specific analysis of the scalp electroencephalogram (EEG) and electrocardiogram (ECG) signals. RESULTS: We evaluated the performance of the system on 5 patients (A-E). For patients A and B the computerized system initiated VNS in response to seizures; for patients C and D the system initiated VNS in response to epileptiform discharges; and for patient E neither seizures nor epileptiform discharges were observed during the evaluation period. During the 81 hour clinical test of the system on patient A, the computerized system detected 5/5 seizures and initiated VNS within 5 seconds of the appearance of ictal discharges in the EEG; VNS did not seem to alter the electrographic or behavioral characteristics of the seizures in this case. During the same testing session the computerized system initiated false stimulations at the rate of 1 false stimulus every 2.5 hours while the subject was at rest and not ambulating. During the 26 hour clinical test of the system on patient B, the computerized system detected 1/1 seizures and initiated VNS within 16 seconds of the appearance of ictal discharges; VNS did not alter the electrographic duration of the seizure but decreased anxiety and increased awareness during the post-seizure recovery phase. During the same testing session the computerized system did not declare any false detections. SIGNIFICANCE: Initiating Vagus nerve stimulation soon after the onset of a seizure may abort or ameliorate seizure symptoms in some patients; unfortunately, a significant number of patients cannot initiate VNS by themselves following the start of a seizure. A system that automatically couples automated detection of seizure onset to initiation of VNS may be helpful for seizure treatment.
Ali H. Shoeb, Trudy Pang, John V. Guttag, Steven Schachter
Int. J. Neural Syst.1