EDBT 2026 Demo / reviewers in the wild / expert
Steven A. Niederer
dblp:95/3103
· DBLP profile ↗
36ranked-venue papers
1as first author
23since 2021 · last 2026
0000-0002-4612-6982ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 34 · 1 first-author · 22 since 2021Graphics, computer vision, multimedia, augmented reality and games · 5 · 4 since 2021Artificial intelligence and machine learning · 2 · 1 since 2021Databases, data management, data science and information retrieval · 1 · 1 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2026 | SegRap2025: A benchmark of gross tumor volume and lymph node clinical target volume Segmentation for Radiotherapy Planning of nasopharyngeal carcinoma
Litingyu Wang, Chenyuan Bian, Zijun Gao, Chunbin Gu, Xin Weng, Jianghao Wu 0001, Yicheng Wu 0001, Jin Ye 0002, Linhao Li, Yiwen Ye, Yong Xia 0001, Elias Tappeiner, Abdul Qayyum 0002, Moona Mazher, Steven A. Niederer, Junqiang Chen, Chuanyi Huang, Lisheng Wang, Zhaohu Xing, Hongqiu Wang, Lei Zhu 0003, Shichuan Zhang, Shaoting Zhang 0001, Wenjun Liao, Guotai Wang |
Medical Image Anal. | 20 |
| 2026 | Multi-class segmentation of aortic branches and zones in computed tomography angiography: The AortaSeg24 challenge
Muhammad Imran 0013, Jonathan R. Krebs, Vishal Balaji Sivaraman, Amarjeet Kumar, Walker R. Ueland, Michael J. Fassler, Lisheng Wang, Maximilian Rokuss, Michael Baumgartner 0001, Yannick Kirchhof, Klaus H. Maier-Hein, Fabian Isensee, Shuolin Liu, Bong Thanh Nguyen, Dong-jin Shin, Park Ji-Woo, Matthew Choi, Kwang-Hyun Uhm, Sung-Jea Ko, Chanwoong Lee, Jaehee Chun, Yun Gu, Zhaohong Pan, Xiaokun Liang, Markus Tiefenthaler, Enrique Almar-Munoz, Matthias Schwab, Mikhail Kotyushev, Rostislav Epifanov, Marek Wodzinski, Henning Müller, Abdul Qayyum 0002, Moona Mazher, Steven A. Niederer, Zhiwei Wang 0002, Kaixiang Yang 0004, Jintao Ren, Stine Sofia Korreman, Yuchong Gao, Hongye Zeng, Jinghua Yue, Fugen Zhou, Alexander Cosman, Muxuan Liang, Gilbert R. Upchurch Jr., Yuyin Zhou, Michol A. Cooper, Wei Shao 0008 |
Medical Image Anal. | 45 |
| 2026 | Extreme cardiac MRI analysis under respiratory motion: Results of the CMRxMotion challenge
Kang Wang 0017, Chen Qin, Zhang Shi, Haoran Wang 0009, Chen Chen 0042, Cheng Ouyang, Chengliang Dai, Yuanhan Mo, Chenchen Dai, Xutong Kuang, Ruizhe Li 0005, Xin Chen 0003, Xiuzheng Yue, Song Tian, Alejandro Mora-Rubio, Kumaradevan Punithakumar, Shizhan Gong, Qi Dou 0001, Sina Amirrajab, Yasmina Alkhalil, Cian M. Scannell, Lexiaozi Fan, Huili Yang, Xiaowu Sun, Rob J. van der Geest, Tewodros Weldebirhan Arega, Fabrice Mériaudeau, Caner Ozer, Amin Ranem, John Kalkhof, Ilkay Öksüz, Anirban Mukhopadhyay 0003, Abdul Qayyum 0002, Moona Mazher, Steven A. Niederer, Carles García-Cabrera, Eric Arazo Sanchez, Michal K. Grzeszczyk, Szymon Plotka, Wanqin Ma, Xiaomeng Li 0001, Rongjun Ge, Yongqing Kou, Xinrong Chen, He Wang 0016, Chengyan Wang, Wenjia Bai, Shuo Wang 0011 |
Medical Image Anal. | 36 |
| 2026 | Advances in automated fetal brain MRI segmentation and biometry: Insights from the FeTA 2024 challengeabstractAccurate fetal brain tissue segmentation and biometric measurement are essential for monitoring neurodevelopment and detecting abnormalities in utero. The Fetal Tissue Annotation (FeTA) Challenges have established robust multi-center benchmarks for evaluating state-of-the-art segmentation methods. This paper presents the results of the 2024 challenge edition, which introduced three key innovations. First, we introduced a topology-aware metric based on the Euler characteristic difference (ED) to overcome the performance plateau observed with traditional metrics like Dice or Hausdorff distance (HD), as the performance of the best models in segmentation surpassed the inter-rater variability. While the best teams reached similar scores in Dice (0.81-0.82) and HD95 (2.1-2.3 mm), ED provided greater discriminative power: the winning method achieved an ED of 20.9, representing roughly a 50% improvement over the second- and third-ranked teams despite comparable Dice scores. Second, we introduced a new 0.55T low-field MRI test set, which, when paired with high-quality super-resolution reconstruction, achieved the highest segmentation performance across all test cohorts (Dice=0.86, HD95=1.69, ED=6.26). This provides the first quantitative evidence that low-cost, low-field MRI can match or surpass high-field systems in automated fetal brain segmentation. Third, the new biometry estimation task exposed a clear performance gap: although the best model reached a mean average percentage error (MAPE) of 7.72%, most submissions failed to outperform a simple gestational-age-based linear regression model (MAPE=9.56%), and all remained above inter-rater variability with a MAPE of 5.38%. Finally, by analyzing the top-performing models from FeTA 2024 alongside those from previous challenge editions, we identify ensembles of 3D nnU-Net trained on both real and synthetic data with both image- and anatomy-level augmentations as the most effective approaches for fetal brain segmentation. Our quantitative analysis reveals that acquisition site, super-resolution strategy, and image quality are the primary sources of domain shift, informing recommendations to enhance the robustness and generalizability of automated fetal brain analysis methods. Vladyslav Zalevskyi, Thomas Sanchez, Misha P. T. Kaandorp, Margaux Roulet, Diego Fajardo-Rojas, Liu Li 0001, Jana Hutter, Hongwei Li 0004, Matthew J. Barkovich, Luca Wilhelmi, Aline Dändliker, Céline Steger, Mériam Koob, Yvan Gomez, Anton Jakovcic, Melita Klaic, Ana Adzic, Pavel Markovic, Gracia Grabaric, Milan Rados, Jordina Aviles Verdera, Gregor Kasprian, Gregor Dovjak, Raphael Gaubert-Rachmühl, Maurice Aschwanden, Davood Karimi, Denis Peruzzo, Tommaso Ciceri, Giorgio Longari, Rachika E. Hamadache, Amina Bouzid, Xavier Lladó, Simone Chiarella, Gerard Martí-Juan, Miguel Ángel González Ballester, Marco Castellaro, Marco Pinamonti, Valentina Visani, Robin Cremese, Keïn Sam, Fleur Gaudfernau, Param Ahir, Mehul Parikh, Maximilian Zenk, Michael Baumgartner 0001, Klaus H. Maier-Hein, Li Tianhong, Zhao Longfei, Domen Preloznik, Ziga Spiclin, Jae Won Choi, Guotai Wang, Lyuyang Tong, Bo Du 0001, Andrea Gondova, Sungmin You, Kiho Im, Abdul Qayyum 0002, Moona Mazher, Steven A. Niederer, András Jakab, Roxane Licandro, Kelly Payette, Meritxell Bach Cuadra |
Medical Image Anal. | 66 |
| 2026 | A model for the human fetal ventricular myocyte electrophysiologyabstractFetal cardiac arrhythmias can lead to stillbirth, but direct studies on the human fetal heart are challenging. To address this, we developed a computational model of human fetal ventricular myocyte (hfVM) electrophysiology, focusing on early gestation (10 weeks). This model incorporates major ionic currents, including fetal-specific T-type calcium and funny currents, and is calibrated using mRNA expression data and experimental measurements. The hfVM model replicates key electrophysiological features, such as a shorter action potential duration and a more positive resting membrane potential compared to adult cells. Global sensitivity analysis reveals that the resting membrane potential is primarily influenced by the funny current and IK1, while action potential repolarisation depends mainly on IKr. Additionally, the sarcoplasmic reticulum contributes to calcium release, but less so than in adults; instead, the T-type calcium current and the sodium-calcium exchanger are more prominent in initiating calcium transients. This is the first human fetal ventricular myocyte model available for studying fetal cardiac physiology, pathology, and potential pharmacological interventions. It provides novel insights into the dominant ion channels governing fetal electrophysiology and calcium dynamics, offering a foundation for understanding arrhythmias and guiding therapeutic strategies. Adelisa Avezzú, Stefano Longobardi, Anita Alvarez-Laviada, Francisca Schultz, Julia Gorelik, Catherine Williamson, Steven A. Niederer |
PLoS Comput. Biol. | 7 |
| 2026 | Two-Stage Self-Supervised Contrastive Learning Aided Transformer for Real-Time Medical Image SegmentationabstractThe availability of large, high-quality annotated datasets in the medical domain poses a substantial challenge in segmentation tasks. To mitigate the reliance on annotated training data, self-supervised pre-training strategies have emerged, particularly employing contrastive learning methods on dense pixel-level representations. In this work, we proposed to capitalize on intrinsic anatomical similarities within medical image data and develop a semantic segmentation framework through a self-supervised fusion network, where the availability of annotated volumes is limited. In a unified training phase, we combine segmentation loss with contrastive loss, enhancing the distinction between significant anatomical regions that adhere to the available annotations. To further improve the segmentation performance, we introduce an efficient parallel transformer module that leverages Multiview multiscale feature fusion and depth-wise features. The proposed transformer architecture, based on multiple encoders, is trained in a self-supervised manner using contrastive loss. Initially, the transformer is trained using an unlabeled dataset. We then fine-tune one encoder using data from the first stage and another encoder using a small set of annotated segmentation masks. These encoder features are subsequently concatenated for the purpose of brain tumor segmentation. The multiencoder-based transformer model yields significantly better outcomes across three medical image segmentation tasks. We validated our proposed solution by fusing images across diverse medical image segmentation challenge datasets, demonstrating its efficacy by outperforming state-of-the-art methodologies. Abdul Qayyum 0002, Muhammad Imran Razzak, Moona Mazher, Tariq Mahmood Khan, Weiping Ding 0001, Steven A. Niederer |
IEEE J. Biomed. Health Informatics | 6 |
| 2026 | MorphiNet: A Graph Subdivision Network for Adaptive Bi-Ventricle Surface ReconstructionabstractCardiac Magnetic Resonance (CMR) imaging is widely used to personalize heart models for cardiac digital twin analysis because of its ability to visualize soft tissues and capture dynamic functions. However, CMR images have an anisotropic nature, characterized by large inter-slice distances and misalignments from cardiac motion. These limitations result in data loss and measurement inaccuracies, hindering the capture of detailed anatomical structures. In this work, we introduce MorphiNet, a novel network that reproduces heart anatomy learned from high-resolution Computed Tomography (CT) images, unpaired with CMR images. MorphiNet encodes the anatomical structure as gradient fields, deforming template meshes into patient-specific geometries. A multilayer graph subdivision network refines these geometries while maintaining dense point correspondence, suitable for downstream computational analysis. MorphiNet achieved the strongest overall trade-off in bi-ventricular myocardium reconstruction on CMR patients with tetralogy of Fallot, with 0.3 higher Dice score and 2.6 lower Hausdorff distance compared to the best existing template-based methods, while achieving comparable geometric accuracy to neural implicit function methods on CT data at $50\times $ faster inference. Cross-dataset validation on the Automated Cardiac Diagnosis Challenge confirmed robust generalization, achieving a 0.7 Dice score with 30% improvement over previous template-based approaches. We validate our anatomical learning approach through the successful restoration of missing cardiac structures and demonstrate significant improvement over standard Loop subdivision. Motion tracking experiments further confirm MorphiNet's capability for cardiac function analysis, including ejection-fraction estimates that correctly identify myocardial dysfunction in tetralogy of Fallot patients. Code and checkpoints are available at https://github.com/MalikTeng/MorphiNetV2. Linglong Qian, Charlène Alice Mauger, Anastasia Nasopoulou, Steven Williams 0001, Michelle C. Williams, Steven A. Niederer, David E. Newby, Andrew D. McCulloch, Jeffrey H. Omens, Kuberan Pushparajah, Alistair A. Young |
IEEE Trans. Medical Imaging | 8 |
| 2025 | Mesh4D: A Motion-Aware Multi-view Variational Autoencoder for 3D+t Mesh Reconstruction
Mengyun Qiao, Qiang Ma 0004, Liu Li 0001, Bernhard Kainz, Declan P. O'Regan, Paul M. Matthews, Steven A. Niederer, Wenjia Bai |
MICCAI (16) | 9 |
| 2025 | Multi-agent Reasoning for Cardiovascular Imaging Phenotype Analysis
Mengyun Qiao, Chengqi Zang, Steven A. Niederer, Paul M. Matthews, Wenjia Bai, Bernhard Kainz |
MICCAI (1) | 4 |
| 2025 | SciBlend: Advanced data visualization workflows within BlenderabstractScientific data visualization is essential for analysis, communication, and storytelling in research. While Blender offers a powerful rendering engine and a flexible 3D environment, its steep learning curve and general-purpose interface can hinder scientific workflows. To address this gap, we present SciBlend, a Python-based toolkit that extends Blender for data visualization. It provides specialized add-ons for multiple computational data files import, annotation, shading, and scene composition, enabling both photorealistic (Cycles) and real-time (EEVEE) rendering of large-scale and time-varying data. By combining a streamlined workflow with physically based rendering, SciBlend supports advanced visualization tasks while preserving essential scientific attributes. Comparative evaluations across multiple case studies show improvements in rendering performance, clarity, and reproducibility relative to traditional tools. This modular and user-oriented design offers a robust solution for creating publication-ready visuals of complex computational data. José Marín, Tiffany M. G. Baptiste, Cristóbal Rodero, Steven Williams 0001, Steven A. Niederer, Ignacio García-Fernández |
Comput. Graph. | 5 |
| 2025 | Regional heterogeneity in left atrial stiffness impacts passive deformation in a cohort of patient-specific modelsabstractIn atrial fibrillation (AF), atrial biomechanics are altered, reducing atrial movement. It remains unclear whether these changes are due to altered anatomy, myocardial stiffness, or constraints from surrounding structures. Understanding the causes of changed atrial deformation in AF could enhance tissue characterization and inform AF diagnosis, stratification, and treatment. We created patient-specific anatomical models of the left atrium (LA) from CT images. Passive LA biomechanics were simulated using finite deformation continuum mechanics equations. LA stiffness was represented by the Guccione material law, where α scaled the anisotropic stiffness parameters. Regional passive stiffness parameters were calibrated to peak regional deformation during the reservoir phase and validated against deformation transients derived from retrospective gated CT images during the reservoir and conduit phase. Physiological LA deformation varies regionally, with the roof deforming significantly less than other regions during the reservoir phase. The fitted model matched peak patient deformations globally and regionally with an average error of [Formula: see text] mm over our cohort. We compared deformation transients through the reservoir and conduit phases and found that the simulated deformation transients were within an average of [Formula: see text] mm per unit time of the CT-derived deformation transients. Regional stiffness varied across the atria with average α values of 1.8, 1.6, 2.2, 1.6 and 2.1 across the cohort in the anterior, posterior, septum, lateral and roof regions respectively. Using mixed effect models, we found no correlation between regional patient LA deformation and regional estimates of wall thickness or regional volumes of epicardial adipose tissue. We found a significant correlation between regionally calibrated stiffness and CT-derived LA biomechanics (p = 0.023). We have shown that regional heterogeneity in stiffness contributes to regional LA biomechanics, while anatomical features appeared less important. These findings provide insight into the underlying causes of altered LA biomechanics in AF. Tiffany M. G. Baptiste, Cristóbal Rodero, Charles Sillett, Marina Strocchi, Christopher W. Lanyon, Christoph M. Augustin, Angela W. C. Lee, José Alonso Solís-Lemus, Caroline H. Roney, Daniel B. Ennis, Ronak Rajani, C. Aldo Rinaldi, Gernot Plank, Richard Wilkinson, Steven Williams 0001, Steven A. Niederer |
PLoS Comput. Biol. | 16 |
| 2025 | Anatomical-electrical coupling of cardiac axes: Definitions and population variability for advancing personalised ECG interpretationabstractElectrocardiogram (ECG) recordings are affected by the heart's three-dimensional orientation within the thorax, i.e., the anatomical axis. Various cardiac conditions can cause the anatomical axis to shift and/or alter the pattern of electrical activation, leading to changes in the electrical axis. Nevertheless, there remains a lack of a formal, population-level study of the interplay between the cardiac anatomical and electrical axes and the factors that affect them. In this context, this study aimed to: (1) propose standardised definitions for the cardiac anatomical and electrical axes, (2) characterise their population-wide interplay in healthy conditions, (3) evaluate the impact of hypertension on their distribution and (4) identify associations with phenotypical and disease characteristics. Using cardiac magnetic resonance images and 12-lead ECGs from ~39,000 UK Biobank participants, patient-specific, paired biventricular geometries and vectorcardiograms were constructed. Five anatomical and four electrical axis definitions were computed, with the optimal pair of definitions selected based on their mutual alignment in 3D space within 28,000 healthy subjects. Accordingly, the anatomical axis was defined as the vector from the apex to the spatial centre of the four valves, and the electrical axis as the direction of the maximum QRS dipole. Mean angular separation in 3D, [Formula: see text], was 145.0° ± 16.8° in the healthy cohort. The electrical axes exhibited a much larger variability, and strong evidence of anatomical-electrical coupling was identified. Increasing BMI notably affected the anatomical axis, rotating the heart more horizontally-a pattern mirrored by the electrical axis. Both axes were also significantly influenced by sex and, to a lesser extent, age. The axes were then studied in the sub-cohort of ~3,500 UK BioBank participants with primary hypertension, where a similar rotational pattern as that with increasing BMI was revealed. Finally, phenome-wide association studies in the 39,000 participants reveal associations between the axes angular metrics and phenotypes signalling an increased afterload, and an association to hypertension among other clinical conditions. These findings underscore the complex anatomical-electrical interplay and highlight the potential of cardiac axes biomarkers for an improved clinical ECG interpretation and disease characterisation. Mohammad Kayyali, Ana Mincholé, Shuang Qian, Alistair A. Young, Devran Ugurlu, Elliot Fairweather, Steven A. Niederer, John Whitaker, Martin J. Bishop 0001, Pablo Lamata |
PLoS Comput. Biol. | 7 |
| 2024 | Federated Focal Modulated UNet for Cardiovascular Image SegmentationabstractFederated learning facilitates collaborative training of machine learning models on data distributed across multiple locations, effectively addressing the privacy concerns by eliminating the need for data centralization—a critical consideration in medical image analysis. In healthcare applications like cardiovascular segmentation, datasets from individual sites often feature annotations for specific heart regions, leading to partial overlaps. To address this challenge, we present a two-step partial annotation framework for federated learning, featuring a hybrid 3D multi-encoding UNet enhanced with focal modulation layers in the second stage. This architecture enables specialized subnetworks to act as experts, extracting features tailored to specific regions of interest based on each client’s data. To further improve feature extraction and differentiation, we incorporate focal modulation blocks and apply regularization by introducing an auxiliary generic decoder during training. Comprehensive experiments on diverse cardiac MRI datasets demonstrate that our approach significantly outperforms centralized learning models. Mohammad Asjad, Abdul Qayyum 0002, Moona Mazher, Usman Naseem, Tariq Mahmood Khan, Steven A. Niederer, Muhammad Imran Razzak |
IEEE Big Data | 6 |
| 2024 | Credibility assessment of in silico clinical trials for medical devicesabstractIn silico clinical trials (ISCTs) are an emerging method in modeling and simulation where medical interventions are evaluated using computational models of patients. ISCTs have the potential to provide cost-effective, time-efficient, and ethically favorable alternatives for evaluating the safety and effectiveness of medical devices. However, ensuring the credibility of ISCT results is a significant challenge. This paper aims to identify unique considerations for assessing the credibility of ISCTs and proposes an ISCT credibility assessment workflow based on recently published model assessment frameworks. First, we review various ISCTs described in the literature, carefully selected to showcase the range of methodological options available. These studies cover a wide variety of devices, reasons for conducting ISCTs, patient model generation approaches including subject-specific versus 'synthetic' virtual patients, complexity levels of devices and patient models, incorporation of clinician or clinical outcome models, and methods for integrating ISCT results with real-world clinical trials. We next discuss how verification, validation, and uncertainty quantification apply to ISCTs, considering the range of ISCT approaches identified. Based on our analysis, we then present a hierarchical workflow for assessing ISCT credibility, using a general credibility assessment framework recently published by the FDA's Center for Devices and Radiological Health. Overall, this work aims to promote standardization in ISCTs and contribute to the wider adoption and acceptance of ISCTs as a reliable tool for evaluating medical devices. Pras Pathmanathan, Kenneth I. Aycock, Andreu Badal, Ramin Bighamian, Jeff Bodner, Brent A. Craven, Steven A. Niederer |
PLoS Comput. Biol. | 7 |
| 2023 | ModusGraph: Automated 3D and 4D Mesh Model Reconstruction from Cine CMR with Improved Accuracy and Efficiency
Sashya Rodrigo, Steven Williams 0001, Michelle C. Williams, Steven A. Niederer, Kuberan Pushparajah, Alistair A. Young |
MICCAI (7) | 6 |
| 2023 | Cell to whole organ global sensitivity analysis on a four-chamber heart electromechanics model using Gaussian processes emulatorsabstractCardiac pump function arises from a series of highly orchestrated events across multiple scales. Computational electromechanics can encode these events in physics-constrained models. However, the large number of parameters in these models has made the systematic study of the link between cellular, tissue, and organ scale parameters to whole heart physiology challenging. A patient-specific anatomical heart model, or digital twin, was created. Cellular ionic dynamics and contraction were simulated with the Courtemanche-Land and the ToR-ORd-Land models for the atria and the ventricles, respectively. Whole heart contraction was coupled with the circulatory system, simulated with CircAdapt, while accounting for the effect of the pericardium on cardiac motion. The four-chamber electromechanics framework resulted in 117 parameters of interest. The model was broken into five hierarchical sub-models: tissue electrophysiology, ToR-ORd-Land model, Courtemanche-Land model, passive mechanics and CircAdapt. For each sub-model, we trained Gaussian processes emulators (GPEs) that were then used to perform a global sensitivity analysis (GSA) to retain parameters explaining 90% of the total sensitivity for subsequent analysis. We identified 45 out of 117 parameters that were important for whole heart function. We performed a GSA over these 45 parameters and identified the systemic and pulmonary peripheral resistance as being critical parameters for a wide range of volumetric and hemodynamic cardiac indexes across all four chambers. We have shown that GPEs provide a robust method for mapping between cellular properties and clinical measurements. This could be applied to identify parameters that can be calibrated in patient-specific models or digital twins, and to link cellular function to clinical indexes. Marina Strocchi, Stefano Longobardi, Christoph M. Augustin, Matthias A. F. Gsell, Argyrios Petras, C. Aldo Rinaldi, Edward J. Vigmond, Gernot Plank, Chris J. Oates, Richard Wilkinson, Steven A. Niederer |
PLoS Comput. Biol. | 11 |
| 2022 | An automated near-real time computational method for induction and treatment of scar-related ventricular tachycardiasabstractCatheter ablation is currently the only curative treatment for scar-related ventricular tachycardias (VTs). However, not only are ablation procedures long, with relatively high risk, but success rates are punitively low, with frequent VT recurrence. Personalized in-silico approaches have the opportunity to address these limitations. However, state-of-the-art reaction diffusion (R-D) simulations of VT induction and subsequent circuits used for in-silico ablation target identification require long execution times, along with vast computational resources, which are incompatible with the clinical workflow. Here, we present the Virtual Induction and Treatment of Arrhythmias (VITA), a novel, rapid and fully automated computational approach that uses reaction-Eikonal methodology to induce VT and identify subsequent ablation targets. The rationale for VITA is based on finding isosurfaces associated with an activation wavefront that splits in the ventricles due to the presence of an isolated isthmus of conduction within the scar; once identified, each isthmus may be assessed for their vulnerability to sustain a reentrant circuit, and the corresponding exit site automatically identified for potential ablation targeting. VITA was tested on a virtual cohort of 7 post-infarcted porcine hearts and the results compared to R-D simulations. Using only a standard desktop machine, VITA could detect all scar-related VTs, simulating activation time maps and ECGs (for clinical comparison) as well as computing ablation targets in 48 minutes. The comparable VTs probed by the R-D simulations took 68.5 hours on 256 cores of high-performance computing infrastructure. The set of lesions computed by VITA was shown to render the ventricular model VT-free. VITA could be used in near real-time as a complementary modality aiding in clinical decision-making in the treatment of post-infarction VTs. Fernando Otaviano Campos, Aurel Neic, Caroline Mendonça Costa, John Whitaker, Mark D. O'Neill, Reza Razavi, C. Aldo Rinaldi, DanielScherr, Steven A. Niederer, Gernot Plank, Martin J. Bishop 0001 |
Medical Image Anal. | 9 |
| 2022 | Modelling the interaction between stem cells derived cardiomyocytes patches and host myocardium to aid non-arrhythmic engineered heart tissue designabstractApplication of epicardial patches constructed from human-induced pluripotent stem cell- derived cardiomyocytes (hiPSC-CMs) has been proposed as a long-term therapy to treat scarred hearts post myocardial infarction (MI). Understanding electrical interaction between engineered heart tissue patches (EHT) and host myocardium represents a key step toward a successful patch engraftment. EHT retain different electrical properties with respect to the host heart tissue due to the hiPSC-CMs immature phenotype, which may lead to increased arrhythmia risk. We developed a modelling framework to examine the influence of patch design on electrical activation at the engraftment site. We performed an in silico investigation of different patch design approaches to restore pre-MI activation properties and evaluated the associated arrhythmic risk. We developed an in silico cardiac electrophysiology model of a transmural cross section of host myocardium. The model featured an infarct region, an epicardial patch spanning the infarct region and a bath region. The patch is modelled as a layer of hiPSC-CM, combined with a layer of conductive polymer (CP). Tissue and patch geometrical dimensions and conductivities were incorporated through 10 modifiable model parameters. We validated our model against 4 independent experimental studies and showed that it can qualitatively reproduce their findings. We performed a global sensitivity analysis (GSA) to isolate the most important parameters, showing that the stimulus propagation is mainly governed by the scar depth, radius and conductivity when the scar is not transmural, and by the EHT patch conductivity when the scar is transmural. We assessed the relevance of small animal studies to humans by comparing simulations of rat, rabbit and human myocardium. We found that stimulus propagation paths and GSA sensitivity indices are consistent across species. We explored which EHT design variables have the potential to restore physiological propagation. Simulations predict that increasing EHT conductivity from 0.28 to 1-1.1 S/m recovered physiological activation in rat, rabbit and human. Finally, we assessed arrhythmia risk related to increasing EHT conductivity and tested increasing the EHT Na+ channel density as an alternative strategy to match healthy activation. Our results revealed a greater arrhythmia risk linked to increased EHT conductivity compared to increased Na+ channel density. We demonstrated that our modeling framework could capture the interaction between host and EHT patches observed in in vitro experiments. We showed that large (patch and tissue dimensions) and small (cardiac myocyte electrophysiology) scale differences between small animals and humans do not alter EHT patch effect on infarcted tissue. Our model revealed that only when the scar is transmural do EHT properties impact activation times and isolated the EHT conductivity as the main parameter influencing propagation. We predicted that restoring physiological activation by tuning EHT conductivity is possible but may promote arrhythmic behavior. Finally, our model suggests that acting on hiPSC-CMs low action potential upstroke velocity and lack of IK1 may restore pre-MI activation while not promoting arrhythmia. Damiano Fassina, Caroline Mendonça Costa, Stefano Longobardi, Elias Karabelas, Gernot Plank, Sian E. Harding, Steven A. Niederer |
PLoS Comput. Biol. | 7 |
| 2022 | Detection of focal source and arrhythmogenic substrate from body surface potentials to guide atrial fibrillation ablationabstractFocal sources (FS) are believed to be important triggers and a perpetuation mechanism for paroxysmal atrial fibrillation (AF). Detecting FS and determining AF sustainability in atrial tissue can help guide ablation targeting. We hypothesized that sustained rotors during FS-driven episodes indicate an arrhythmogenic substrate for sustained AF, and that non-invasive electrical recordings, like electrocardiograms (ECGs) or body surface potential maps (BSPMs), could be used to detect FS and AF sustainability. Computer simulations were performed on five bi-atrial geometries. FS were induced by pacing at cycle lengths of 120-270 ms from 32 atrial sites and four pulmonary veins. Self-sustained reentrant activities were also initiated around the same 32 atrial sites with inexcitable cores of radii of 0, 0.5 and 1 cm. FS fired for two seconds and then AF inducibility was tested by whether activation was sustained for another second. ECGs and BSPMs were simulated. Equivalent atrial sources were extracted using second-order blind source separation, and their cycle length, periodicity and contribution, were used as features for random forest classifiers. Longer rotor duration during FS-driven episodes indicates higher AF inducibility (area under ROC curve = 0.83). Our method had accuracy of 90.6±1.0% and 90.6±0.6% in detecting FS presence, and 93.1±0.6% and 94.2±1.2% in identifying AF sustainability, and 80.0±6.6% and 61.0±5.2% in determining the atrium of the focal site, from BSPMs and ECGs of five atria. The detection of FS presence and AF sustainability were insensitive to vest placement (±9.6%). On pre-operative BSPMs of 52 paroxysmal AF patients, patients classified with initiator-type FS on a single atrium resulted in improved two-to-three-year AF-free likelihoods (p-value < 0.01, logrank tests). Detection of FS and arrhythmogenic substrate can be performed from ECGs and BSPMs, enabling non-invasive mapping towards mechanism-targeted AF treatment, and malignant ectopic beat detection with likely AF progression. Yingjing Feng, Caroline H. Roney, Jason D. Bayer, Steven A. Niederer, Mélèze Hocini, Edward J. Vigmond |
PLoS Comput. Biol. | 4 |
| 2022 | Credibility assessment of patient-specific computational modeling using patient-specific cardiac modeling as an exemplarabstractReliable and robust simulation of individual patients using patient-specific models (PSMs) is one of the next frontiers for modeling and simulation (M&S) in healthcare. PSMs, which form the basis of digital twins, can be employed as clinical tools to, for example, assess disease state, predict response to therapy, or optimize therapy. They may also be used to construct virtual cohorts of patients, for in silico evaluation of medical product safety and/or performance. Methods and frameworks have recently been proposed for evaluating the credibility of M&S in healthcare applications. However, such efforts have generally been motivated by models of medical devices or generic patient models; how best to evaluate the credibility of PSMs has largely been unexplored. The aim of this paper is to understand and demonstrate the credibility assessment process for PSMs using patient-specific cardiac electrophysiological (EP) modeling as an exemplar. We first review approaches used to generate cardiac PSMs and consider how verification, validation, and uncertainty quantification (VVUQ) apply to cardiac PSMs. Next, we execute two simulation studies using a publicly available virtual cohort of 24 patient-specific ventricular models, the first a multi-patient verification study, the second investigating the impact of uncertainty in personalized and non-personalized inputs in a virtual cohort. We then use the findings from our analyses to identify how important characteristics of PSMs can be considered when assessing credibility with the approach of the ASME V&V40 Standard, accounting for PSM concepts such as inter- and intra-user variability, multi-patient and "every-patient" error estimation, uncertainty quantification in personalized vs non-personalized inputs, clinical validation, and others. The results of this paper will be useful to developers of cardiac and other medical image based PSMs, when assessing PSM credibility. Suran Galappaththige, Richard A. Gray, Caroline Mendonça Costa, Steven A. Niederer, Pras Pathmanathan |
PLoS Comput. Biol. | 4 |
| 2022 | Correction: Linking statistical shape models and simulated function in the healthy adult human heartabstract[This corrects the article DOI: 10.1371/journal.pcbi.1008851.]. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 12 |
| 2021 | In silico identification of potential calcium dynamics and sarcomere targets for recovering left ventricular function in rat heart failure with preserved ejection fractionabstractHeart failure with preserved ejection fraction (HFpEF) is a complex disease associated with multiple co-morbidities, where impaired cardiac mechanics are often the end effect. At the cellular level, cardiac mechanics can be pharmacologically manipulated by altering calcium signalling and the sarcomere. However, the link between cellular level modulations and whole organ pump function is incompletely understood. Our goal is to develop and use a multi-scale computational cardiac mechanics model of the obese ZSF1 HFpEF rat to identify important biomechanical mechanisms that underpin impaired cardiac function and to predict how whole-heart mechanical function can be recovered through altering cellular calcium dynamics and/or cellular contraction. The rat heart was modelled using a 3D biventricular biomechanics model. Biomechanics were described by 16 parameters, corresponding to intracellular calcium transient, sarcomere dynamics, cardiac tissue and hemodynamics properties. The model simulated left ventricular (LV) pressure-volume loops that were described by 14 scalar features. We trained a Gaussian process emulator to map the 16 input parameters to each of the 14 outputs. A global sensitivity analysis was performed, and identified calcium dynamics and thin and thick filament kinetics as key determinants of the organ scale pump function. We employed Bayesian history matching to build a model of the ZSF1 rat heart. Next, we recovered the LV function, described by ejection fraction, peak pressure, maximum rate of pressure rise and isovolumetric relaxation time constant. We found that by manipulating calcium, thin and thick filament properties we can recover 34%, 28% and 24% of the LV function in the ZSF1 rat heart, respectively, and 39% if we manipulate all of them together. We demonstrated how a combination of biophysically based models and their derived emulators can be used to identify potential pharmacological targets. We predicted that cardiac function can be best recovered in ZSF1 rats by desensitising the myofilament and reducing the affinity to intracellular calcium concentration and overall prolonging the sarcomere staying in the active force generating state. Stefano Longobardi, Anna Sher, Steven A. Niederer |
PLoS Comput. Biol. | 3 |
| 2021 | Linking statistical shape models and simulated function in the healthy adult human heartabstractCardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n = 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R = 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 12 |
| 2020 | Quantifying atrial anatomy uncertainty from clinical data and its impact on electro-physiology simulation predictionsabstractPatient-specific computational models of structure and function are increasingly being used to diagnose disease and predict how a patient will respond to therapy. Models of anatomy are often derived after segmentation of clinical images or from mapping systems which are affected by image artefacts, resolution and contrast. Quantifying the impact of uncertain anatomy on model predictions is important, as models are increasingly used in clinical practice where decisions need to be made regardless of image quality. We use a Bayesian probabilistic approach to estimate the anatomy and to quantify the uncertainty about the shape of the left atrium derived from Cardiac Magnetic Resonance images. We show that we can quantify uncertain shape, encode uncertainty about the left atrial shape due to imaging artefacts, and quantify the effect of uncertain shape on simulations of left atrial activation times. Cesare Corrado, Orod Razeghi, Caroline H. Roney, Sam Coveney, Steven Williams 0001, Iain Sim, Mark D. O'Neill, Richard Wilkinson, Jeremy E. Oakley, Richard H. Clayton, Steven A. Niederer |
Medical Image Anal. | 11 |
| 2019 | A rule-based method for predicting the electrical activation of the heart with cardiac resynchronization therapy from non-invasive clinical dataabstractBACKGROUND: Cardiac Resynchronization Therapy (CRT) is one of the few effective treatments for heart failure patients with ventricular dyssynchrony. The pacing location of the left ventricle is indicated as a determinant of CRT outcome. OBJECTIVE: Patient specific computational models allow the activation pattern following CRT implant to be predicted and this may be used to optimize CRT lead placement. METHODS: In this study, the effects of heterogeneous cardiac substrate (scar, fast endocardial conduction, slow septal conduction, functional block) on accurately predicting the electrical activation of the LV epicardium were tested to determine the minimal detail required to create a rule based model of cardiac electrophysiology. Non-invasive clinical data (CT or CMR images and 12 lead ECG) from eighteen patients from two centers were used to investigate the models. RESULTS: Validation with invasive electro-anatomical mapping data identified that computer models with fast endocardial conduction were able to predict the electrical activation with a mean distance errors of 9.2 ± 0.5 mm (CMR data) or (CT data) 7.5 ± 0.7 mm. CONCLUSION: This study identified a simple rule-based fast endocardial conduction model, built using non-invasive clinical data that can be used to rapidly and robustly predict the electrical activation of the heart. Pre-procedural prediction of the latest electrically activating region to identify the optimal LV pacing site could potentially be a useful clinical planning tool for CRT procedures. Angela W. C. Lee, Uyen Chau Nguyen, Orod Razeghi, Justin Gould, Baldeep Sidhu, Benjamin Sieniewicz, Jonathan M. Behar, M. Mafi-Rad, Gernot Plank, Frits W. Prinzen, C. Aldo Rinaldi, Kevin Vernooy, Steven A. Niederer |
Medical Image Anal. | 13 |
| 2019 | Universal atrial coordinates applied to visualisation, registration and construction of patient specific meshesabstractIntegrating spatial information about atrial physiology and anatomy in a single patient from multimodal datasets, as well as generalizing these data across patients, requires a common coordinate system. In the atria, this is challenging due to the complexity and variability of the anatomy. We aimed to develop and validate a Universal Atrial Coordinate (UAC) system for the following applications: combination and assessment of multimodal data; comparison of spatial data across patients; 2D visualization; and construction of patient specific geometries to test mechanistic hypotheses. Left and right atrial LGE-MRI data were segmented and meshed. Two coordinates were calculated for each atrium by solving Laplace's equation, with boundary conditions assigned using five landmark points. The coordinate system was used to map spatial information between atrial meshes, including scalar fields measured using different mapping modalities, and atrial anatomic structures and fibre directions from a reference geometry. Average error in point transfer from a source mesh to a destination mesh and back again was less than 0.1 mm for the left atrium and 0.02 mm for the right atrium. Patient specific meshes were constructed using the coordinate system and phase singularity density maps from arrhythmia simulations were visualised in 2D. In conclusion, we have developed a universal atrial coordinate system allowing automatic registration of imaging and electroanatomic mapping data, 2D visualisation, and patient specific model creation. Caroline H. Roney, Ali Pashaei, Marianna Meo, Rémi Dubois, Patrick M. Boyle, Natalia A. Trayanova, Hubert Cochet, Steven A. Niederer, Edward J. Vigmond |
Medical Image Anal. | 8 |
| 2018 | A work flow to build and validate patient specific left atrium electrophysiology models from catheter measurementsabstractBiophysical models of the atrium provide a physically constrained framework for describing the current state of an atrium and allow predictions of how that atrium will respond to therapy. We propose a work flow to simulate patient specific electrophysiological heterogeneity from clinical data and validate the resulting biophysical models. In 7 patients, we recorded the atrial anatomy with an electroanatomical mapping system (St Jude Velocity); we then applied an S1-S2 electrical stimulation protocol from the coronary sinus (CS) and the high right atrium (HRA) whilst recording the activation patterns using a PentaRay catheter with 10 bipolar electrodes at 12 ± 2 sites across the atrium. Using only the activation times measured with a PentaRay catheter and caused by a stimulus applied in the CS with a remote catheter we fitted the four parameters for a modified Mitchell-Schaeffer model and the tissue conductivity to the recorded local conduction velocity restitution curve and estimated local effective refractory period. Model parameters were then interpolated across each atrium. The fitted model recapitulated the S1-S2 activation times for CS pacing giving a correlation ranging between 0.81 and 0.98. The model was validated by comparing simulated activations times with the independently recorded HRA pacing S1-S2 activation times, giving a correlation ranging between 0.65 and 0.96. The resulting work flow provides the first validated cohort of models that capture clinically measured patient specific electrophysiological heterogeneity. Cesare Corrado, Steven Williams 0001, Rashed Karim, Gernot Plank, Mark D. O'Neill, Steven A. Niederer |
Medical Image Anal. | 6 |
| 2018 | Personalized computational modeling of left atrial geometry and transmural myofiber architectureabstractAtrial fibrillation (AF) is a supraventricular tachyarrhythmia characterized by complete absence of coordinated atrial contraction and is associated with an increased morbidity and mortality. Personalized computational modeling provides a novel framework for integrating and interpreting the role of atrial electrophysiology (EP) including the underlying anatomy and microstructure in the development and sustenance of AF. Coronary computed tomography angiography data were segmented using a statistics-based approach and the smoothed voxel representations were discretized into high-resolution tetrahedral finite element (FE) meshes. To estimate the complex left atrial myofiber architecture, individual fiber fields were generated according to morphological data on the endo- and epicardial surfaces based on local solutions of Laplace's equation and transmurally interpolated to tetrahedral elements. The influence of variable transmural microstructures was quantified through EP simulations on 3 patients using 5 different fiber interpolation functions. Personalized geometrical models included the heterogeneous thickness distribution of the left atrial myocardium and subsequent discretization led to high-fidelity tetrahedral FE meshes. The novel algorithm for automated incorporation of the left atrial fiber architecture provided a realistic estimate of the atrial microstructure and was able to qualitatively capture all important fiber bundles. Consistent maximum local activation times were predicted in EP simulations using individual transmural fiber interpolation functions for each patient suggesting a negligible effect of the transmural myofiber architecture on EP. The established modeling pipeline provides a robust framework for the rapid development of personalized model cohorts accounting for detailed anatomy and microstructure and facilitates simulations of atrial EP. Thomas E. Fastl, Catalina Tobon-Gomez, Andrew Crozier, John Whitaker, Ronak Rajani, Karen P. McCarthy, Damian Sánchez-Quintana, Siew Y. Ho, Mark D. O'Neill, Gernot Plank, Martin J. Bishop 0001, Steven A. Niederer |
Medical Image Anal. | 12 |
| 2017 | Probabilistic Models for Integration Error in the Assessment of Functional Cardiac ModelsabstractThis paper studies the numerical computation of integrals, representing estimates or predictions, over the output $f(x)$ of a computational model with respect to a distribution $p(\mathrm{d}x)$ over uncertain inputs $x$ to the model. For the functional cardiac models that motivate this work, neither $f$ nor $p$ possess a closed-form expression and evaluation of either requires $\approx$ 100 CPU hours, precluding standard numerical integration methods. Our proposal is to treat integration as an estimation problem, with a joint model for both the a priori unknown function $f$ and the a priori unknown distribution $p$. The result is a posterior distribution over the integral that explicitly accounts for dual sources of numerical approximation error due to a severely limited computational budget. This construction is applied to account, in a statistically principled manner, for the impact of numerical errors that (at present) are confounding factors in functional cardiac model assessment. Chris J. Oates, Steven A. Niederer, Angela W. C. Lee, François-Xavier Briol, Mark A. Girolami |
NIPS | 2 |
| 2016 | A Biophysical Systems Approach to Identifying the Pathways of Acute and Chronic Doxorubicin Mitochondrial CardiotoxicityabstractThe clinical use of the anthracycline doxorubicin is limited by its cardiotoxicity which is associated with mitochondrial dysfunction. Redox cycling, mitochondrial DNA damage and electron transport chain inhibition have been identified as potential mechanisms of toxicity. However, the relative roles of each of these proposed mechanisms are still not fully understood. The purpose of this study is to identify which of these pathways independently or in combination are responsible for doxorubicin toxicity. A state of the art mathematical model of the mitochondria including the citric acid cycle, electron transport chain and ROS production and scavenging systems was extended by incorporating a novel representation for mitochondrial DNA damage and repair. In silico experiments were performed to quantify the contributions of each of the toxicity mechanisms to mitochondrial dysfunction during the acute and chronic stages of toxicity. Simulations predict that redox cycling has a minor role in doxorubicin cardiotoxicity. Electron transport chain inhibition is the main pathway for acute toxicity for supratherapeutic doses, being lethal at mitochondrial concentrations higher than 200μM. Direct mitochondrial DNA damage is the principal pathway of chronic cardiotoxicity for therapeutic doses, leading to a progressive and irreversible long term mitochondrial dysfunction. Bernardo Lino de Oliveira, Steven A. Niederer |
PLoS Comput. Biol. | 2 |
| 2015 | A Spatially Detailed Model of Isometric Contraction Based on Competitive Binding of Troponin I Explains Cooperative Interactions between Tropomyosin and CrossbridgesabstractBiophysical models of cardiac tension development provide a succinct representation of our understanding of force generation in the heart. The link between protein kinetics and interactions that gives rise to high cooperativity is not yet fully explained from experiments or previous biophysical models. We propose a biophysical ODE-based representation of cross-bridge (XB), tropomyosin and troponin within a contractile regulatory unit (RU) to investigate the mechanisms behind cooperative activation, as well as the role of cooperativity in dynamic tension generation across different species. The model includes cooperative interactions between regulatory units (RU-RU), between crossbridges (XB-XB), as well more complex interactions between crossbridges and regulatory units (XB-RU interactions). For the steady-state force-calcium relationship, our framework predicts that: (1) XB-RU effects are key in shifting the half-activation value of the force-calcium relationship towards lower [Ca(2+)], but have only small effects on cooperativity. (2) XB-XB effects approximately double the duty ratio of myosin, but do not significantly affect cooperativity. (3) RU-RU effects derived from the long-range action of tropomyosin are a major factor in cooperative activation, with each additional unblocked RU increasing the rate of additional RU's unblocking. (4) Myosin affinity for short (1-4 RU) unblocked stretches of actin of is very low, and the resulting suppression of force at low [Ca(2+)] is a major contributor in the biphasic force-calcium relationship. We also reproduce isometric tension development across mouse, rat and human at physiological temperature and pacing rate, and conclude that species differences require only changes in myosin affinity and troponin I/troponin C affinity. Furthermore, we show that the calcium dependence of the rate of tension redevelopment k(tr) is explained by transient blocking of RU's by a temporary decrease in XB-RU effects. Sander Land, Steven A. Niederer |
PLoS Comput. Biol. | 2 |
| 2013 | The estimation of patient-specific cardiac diastolic functions from clinical measurementsabstractAn unresolved issue in patients with diastolic dysfunction is that the estimation of myocardial stiffness cannot be decoupled from diastolic residual active tension (AT) because of the impaired ventricular relaxation during diastole. To address this problem, this paper presents a method for estimating diastolic mechanical parameters of the left ventricle (LV) from cine and tagged MRI measurements and LV cavity pressure recordings, separating the passive myocardial constitutive properties and diastolic residual AT. Dynamic C1-continuous meshes are automatically built from the anatomy and deformation captured from dynamic MRI sequences. Diastolic deformation is simulated using a mechanical model that combines passive and active material properties. The problem of non-uniqueness of constitutive parameter estimation using the well known Guccione law is characterized by reformulation of this law. Using this reformulated form, and by constraining the constitutive parameters to be constant across time points during diastole, we separate the effects of passive constitutive properties and the residual AT during diastolic relaxation. Finally, the method is applied to two clinical cases and one control, demonstrating that increased residual AT during diastole provides a potential novel index for delineating healthy and pathological cases. Jiahe Xi, Pablo Lamata, Steven A. Niederer, Sander Land, Wenzhe Shi, Xiahai Zhuang, Sébastien Ourselin, Simon G. Duckett, Anoop Shetty, C. Aldo Rinaldi, Daniel Rueckert, Reza Razavi, Nicolas Smith |
Medical Image Anal. | 3 |
| 2013 | Quality Metrics for High Order Meshes: Analysis of the Mechanical Simulation of the Heart BeatabstractThe quality of a computational mesh is an important characteristic for stable and accurate simulations. Quality depends on the regularity of the initial mesh, and in mechanical simulations it evolves in time, with deformations causing changes in volume and distortion of mesh elements. Mesh quality metrics are therefore relevant for both mesh personalization and the monitoring of the simulation process. This work evaluates the significance, in meshes with high order interpolation, of four quality metrics described in the literature, applying them to analyse the stability of the simulation of the heart beat. It also investigates how image registration and mesh warping parameters affect the quality and stability of meshes. Jacobian-based metrics outperformed or matched the results of coarse geometrical metrics of aspect ratio or orthogonality, although they are more expensive computationally. The stability of simulations of a complete heart cycle was best predicted with a specificity of 61%, sensitivity of 85%, and only nominal differences were found changing the intra-element and per-element combination of quality values. A compromise between fitting accuracy and mesh stability and quality was found. Generic geometrical quality metrics have a limited success predicting stability, and an analysis of the simulation problem may be required for an optimal definition of quality. Pablo Lamata, Ishani Roy, Bojan Blazevic, Andrew Crozier, Sander Land, Steven A. Niederer, Rod D. Hose, Nicolas Smith |
IEEE Trans. Medical Imaging | 6 |
| 2011 | An accurate, fast and robust method to generate patient-specific cubic Hermite meshes
Pablo Lamata, Steven A. Niederer, David Nordsletten, David C. Barber, Ishani Roy, Rod D. Hose, Nicolas Smith |
Medical Image Anal. | 2 |
| 2010 | Personalization of Cubic Hermite Meshes for Efficient Biomechanical Simulations
Pablo Lamata, Steven A. Niederer, David C. Barber, David Nordsletten, Jack Lee, Rod D. Hose, Nicolas Smith |
MICCAI (2) | 2 |
| 2009 | The Role of the Frank-Starling Law in the Transduction of Cellular Work to Whole Organ Pump Function: A Computational Modeling AnalysisabstractWe have developed a multi-scale biophysical electromechanics model of the rat left ventricle at room temperature. This model has been applied to investigate the relative roles of cellular scale length dependent regulators of tension generation on the transduction of work from the cell to whole organ pump function. Specifically, the role of the length dependent Ca(2+) sensitivity of tension (Ca(50)), filament overlap tension dependence, velocity dependence of tension, and tension dependent binding of Ca(2+) to Troponin C on metrics of efficient transduction of work and stress and strain homogeneity were predicted by performing simulations in the absence of each of these feedback mechanisms. The length dependent Ca(50) and the filament overlap, which make up the Frank-Starling Law, were found to be the two dominant regulators of the efficient transduction of work. Analyzing the fiber velocity field in the absence of the Frank-Starling mechanisms showed that the decreased efficiency in the transduction of work in the absence of filament overlap effects was caused by increased post systolic shortening, whereas the decreased efficiency in the absence of length dependent Ca(50) was caused by an inversion in the regional distribution of strain. Steven A. Niederer, Nicolas Smith |
PLoS Comput. Biol. | 1 |