EDBT 2026 Demo / reviewers in the wild / expert
Richard Malthaner
dblp:98/5151 · also Richard A. Malthaner
· DBLP profile ↗
6ranked-venue papers
0as first author
0since 2021 · last 2015
0000-0002-3763-4838ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 6Systems, architecture and hardware · 6
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
4 papers |
Medical and health informatics · 100% | |
| Artificial intelligence
1 paper |
Robot manipulation · 100% |
Topics — the 7 heaviest of 7, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics
computer-assisted surgery |
0.3 | 3 | 2013 | The application of force sensing to skills assessment in Minimally Invasive Surgery · ICRA 2013 MIRA V: An integrated system for minimally invasive robot-assisted lung brachytherapy · ICRA 2008 A Device for Robot-assisted Minimally-invasive Lung Brachytherapy · ICRA 2006 |
Medical and health informatics
surgical robotics |
0.3 | 3 | 2013 | The application of force sensing to skills assessment in Minimally Invasive Surgery · ICRA 2013 MIRA V: An integrated system for minimally invasive robot-assisted lung brachytherapy · ICRA 2008 A Device for Robot-assisted Minimally-invasive Lung Brachytherapy · ICRA 2006 |
Medical and health informatics › surgical robotics
minimally invasive surgery |
0.2 | 1 | 2015 | A multi-sensory mechatronic device for localizing tumors in minimally invasive interventions · ICRA 2015 |
Medical and health informatics › computational pathology
tumor localization |
0.2 | 1 | 2015 | A multi-sensory mechatronic device for localizing tumors in minimally invasive interventions · ICRA 2015 |
Medical and health informatics › surgical robotics
force sensing |
0.2 | 1 | 2013 | The application of force sensing to skills assessment in Minimally Invasive Surgery · ICRA 2013 |
Medical and health informatics › computer-assisted surgery
brachytherapy |
0.1 | 2 | 2008 | MIRA V: An integrated system for minimally invasive robot-assisted lung brachytherapy · ICRA 2008 A Device for Robot-assisted Minimally-invasive Lung Brachytherapy · ICRA 2006 |
Robotics › Robot manipulation
tactile sensing |
0.1 | 1 | 2015 | A multi-sensory mechatronic device for localizing tumors in minimally invasive interventions · ICRA 2015 |
Methods — techniques the papers use, named apart from their topics
ultrasound sensing · 0.4fluoroscopic imaging · 0.4force-based metrics · 0.2dosimetry planning · 0.1image-guided needle placement · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2015 | A multi-sensory mechatronic device for localizing tumors in minimally invasive interventionsabstractTumor localization in traditional lung resection surgery requires manual palpation of the deflated lung through a thoracotomy. It is a painful procedure that is not suitable for many patients. Therefore, a multisensory mechatronic device was designed to localize tumors using a minimally invasive approach. The device is sensorized with tactile, ultrasound and position sensors in order to obtain multimodal data of soft tissue in real time. This paper presents the validation of the efficiency and efficacy of this device via an ex vivo experimental study. Tumor pathology was simulated by embedding iodine-agar phantom tumors of varying shapes and sizes into porcine liver tissue. The device was then used to palpate the tissue to localize and visualize the simulated tumors. Markers were then placed on the location of the tumors and fluoroscopic imaging was performed on the tissue in order to determine the localization accuracy of the device. Our results show that the device localized 87.5% of the tumors with an average deviation from the tumor center of 3.42 mm. Abelardo Escoto, Srikanth Bhattad, Arefin Shamsil, Andre Sanches, Ana Luisa Trejos, Michael D. Naish, Richard Malthaner, Rajnikant V. Patel |
ICRA | 7 |
| 2013 | The application of force sensing to skills assessment in Minimally Invasive SurgeryabstractThe reduced access conditions present in Minimally Invasive Surgery (MIS) affect the feel of interaction forces between the instruments and the tissue being treated. This loss of haptic information compromises the safety of the procedure and must be overcome through training. Determining the skill level of trainees is critical for ensuring patient safety. The objective of this work was to evaluate the usefulness of force information for skills assessment during MIS. Experiments were performed using a set of sensorized instruments capable of measuring instrument position and tissue interaction forces. The results show that experience level has a strong correlation with force-based metrics. The proposed metrics can be automatically computed, are completely objective, and measure important aspects of performance. Ana Luisa Trejos, Rajnikant V. Patel, Michael D. Naish, Richard Malthaner, Christopher Schlachta |
ICRA | 4 |
| 2008 | MIRA V: An integrated system for minimally invasive robot-assisted lung brachytherapyabstractAn integrated system for minimally invasive robot-assisted image-guided lung brachytherapy has been developed. The system incorporates an experimental setup for accurate radioactive seed placement with commercially available dosimetry planning software. The end result is a complete system that allows planning and executing a brachytherapy procedure with increased accuracy. The results of the in vitro seed placement evaluation show that seed misplacement has a significant effect on the volume receiving more than 200% of the dose (V200), and the minimum dosage received by 90% of the volume (D90). Ana Luisa Trejos, Amy Wei Lin, Shiva Mohan, Harmanpreet Bassan, Chandima Edirisinghe, Rajnikant V. Patel, Craig Lewis, Edward Yu, Aaron Fenster, Richard Malthaner |
ICRA | 10 |
| 2007 | Evaluation of force feedback requirements for minimally invasive lung tumour localizationabstractMinimally invasive surgery is a technique that provides numerous benefits to the patient, but presents challenges to the surgeon in that dexterity, hand-eye coordination and haptic perception are compromised. Robot-assisted minimally invasive approaches have addressed the problems of dexterity and coordination; however, the lack of kinesthetic and tactile feedback remains a significant drawback. Despite many advances in this area, little is currently known about what level of feedback performance is adequate to allow the surgeon to palpate tissue to detect an underlying tumour. This paper describes experiments that were conducted on ex-vivo porcine lung, using artificial tumours, to elucidate one measure of sensor performance required to detect the presence of a tumour. The results indicate that a force- sensitive probe with a sensing range of 0 to 10 N and a resolution of 0.01 N would allow a tumour to be localized via palpation using kinesthetic feedback. Greig L. McCreery, Ana Luisa Trejos, Rajnikant V. Patel, Michael D. Naish, Richard Malthaner |
IROS | 5 |
| 2007 | An experimental test-bed for robot-assisted image-guided minimally invasive lung brachytherapyabstractAn experimental test-bed for robot-assisted image-guided minimally invasive lung brachytherapy has been developed. The setup includes surgical robots, a device to accurately drop brachytherapy seeds, an ultrasound system, electromagnetic trackers, and navigational software. An evaluation using the test-bed was performed to compare the open procedure and the video-assisted thoracoscopic procedure with the proposed robot-assisted minimally invasive procedure under ultrasound image guidance and electromagnetic tracking. The results show that the use of robotic systems and image guidance can provide improved seed placement accuracy as compared to open surgery, while reducing the invasiveness of the procedure and trauma to the patient's body. Ana Luisa Trejos, Shiva Mohan, Harmanpreet Bassan, Amy Wei Lin, Aida Kashigar, Rajnikant V. Patel, Richard Malthaner |
IROS | 7 |
| 2006 | A Device for Robot-assisted Minimally-invasive Lung BrachytherapyabstractA device for robot-assisted brachytherapy has been designed for use with a minimally-invasive surgical robot such as the ZEUStrade It may be loaded with a standard brachytherapy needle allowing the robot to position its tip at a specified location within cancerous tissue. The device accurately retracts a hollow needle loaded with radioactive seeds while a stationary plunger pushes the seeds out into the tissue. The position error when retracting the needle is less than 0.05 mm. The use of this device, together with image-guidance for needle placement, can improve radiation dose delivery when treating certain types of lung cancer. The incorporation of this device into robotic systems that are already approved for clinical use can potentially allow it to be commercialized much sooner than competitive technology Ana Luisa Trejos, Rajnikant V. Patel, Richard Malthaner |
ICRA | 3 |